Best backflow test kit

Three five-valve kits scored on their own spec sheets and the USC lists.

As an Amazon Associate I earn from qualifying purchases. How this site earns

Updated November 15, 2026

About Isaac · How I chose

Arbiter Mako MK5 backflow test kit
Arbiter Mako MK5 backflow test kit. Product photo from Amazon listing.
On this page
  1. The picks
  2. Reading margin
  3. Arbiter Mako MK5
  4. Mid-West 845-5
  5. Bac-Flo-5
  6. Compare
  7. USC lists
  8. Dial or digital
  9. Five valves
  10. Calibration
  11. A test in brief
  12. Why a gauge
  13. Hoses
  14. Double check test
  15. Also checked
  16. How to choose
  17. FAQ
  18. How I pick

SHORT ANSWER

Get the Arbiter Mako MK5 (10.0): the one kit on the USC approved list, ±0.1 psid. For a dial gauge, the Mid-West 845-5 or Bac-Flo-5. Ask your water authority which kits it accepts first.

Arbiter Mako MK5 digital backflow test gauge with red, yellow and blue hoses
Top pick: Arbiter Mako MK5$999.99 at AmazonPrice as of Nov 22, 2026, 9:30 AM EST
Check it on Amazon

Three five-valve backflow test kits

All three measure differential pressure from 0 to 15 psid and test reduced pressure, double check and vacuum breaker assemblies. Scored on the same seven checks from the makers’ sheets and the USC Foundation’s lists, read Oct 24, 2026. I’ve used these picks.

How much a kit’s accuracy matters on a close call

Pick a kit and enter a relief valve opening reading. The checker shows the range the true value could be in, given that kit’s stated accuracy.

Mid-West 845-5 (±0.2 psid): a 2.1 psid reading could be 1.9 to 2.3 psid; the range straddles 2.0 psid, so the reading alone can’t settle it.

Accuracy from each maker’s sheet; the Watts figure is ±2% of the 15 psid full scale, or ±0.3 psid. The 2.0 psid line is the relief valve requirement in Watts’ TK-9A test procedure. Your authority’s procedure and pass rules govern; this only shows the gauge’s margin.

Gauge accuracy matters most when a reading sits near a pass line. Watts’ TK-9A instructions say the relief valve on a reduced pressure assembly must keep the zone between the checks at least 2 psi below supply pressure. A reading just over 2.0 on a gauge that can be off by 0.2 doesn’t prove much.

Arbiter lists the Mako MK5 at ±0.1 psid from 0 to 15 psid, if it has been calibrated in the past 12 months and runs firmware version 12 or later. Mid-West and Bac-Flo list ±0.2 psid on the descending scale. Watts lists ±2% of full scale on the TK-9A’s 0–15 psid gauge.

Arbiter Mako MK510Mid-West 845-510Bac-Flo-510010Arbiter Mako MK510Mid-West 845-510Bac-Flo-510
PlumbingPicks spec score out of 10, from the makers’ spec sheets and the USC Foundation’s lists, read Oct 24, 2026. It is not a customer rating.
Best for USC approved testing

Arbiter Mako MK5

Digital 5-valve backflow test kit with hoses and case

MK5
$999.99
Check it on Amazon
in stock · price as of Nov 22, 2026, 9:30 AM EST
10Spec scoreHow it’s scored
On a USC Foundation list10
±0.2 psid or better10
Five-valve kit10
Inline hose filters10
175 psi or more working pressure10
Warranty 2 years or more10
Carrying case included10

Pros

  • On the USC List of Approved Field Test Kits (10th edition)
  • ±0.1 psid from 0 to 15 psid
  • Capture button and backlit display
  • IP57, 5-year warranty from manufacture

Cons

  • Runs on 4 AA batteries
  • Accuracy figure depends on yearly calibration and current firmware
  • Opening the unit past the battery compartment voids the warranty
0–15 psid±0.1 psid5 valves175 psi maxIP57

Buy it if

Your authority requires a kit on the USC Foundation’s approved list, or you want a digital readout that stores readings.

Skip it if

You’d rather not depend on batteries and firmware; the dial kits need neither.

The Mako MK5 is the kit I’d get if I were buying one today, and I’ve used it. It scored 10.0, passing all seven checks.

Its standout fact is the list it’s on. The USC Foundation’s List of Approved Field Test Kits, dated December 10, 2019, names one kit: the Arbiter Mako MK5, five-valve configuration, approved under the Tenth Edition of the Manual of Cross-Connection Control. Arbiter’s manual calls it the only USC FCCCHR Manual 10 approved gauge.

Accuracy is ±0.1 psid from 0 to 15 psid, per Arbiter’s manual, provided it has been calibrated in the past 12 months and runs firmware version 12 or later.

Above 15 psid it widens: ±1% of reading to 100 psid, ±5% to 150 and ±10% to 175. The manual notes that USC approval requires at least ±0.2 psid across its working temperatures and pressures, and that the Mako passed that testing at the USC lab.

It’s digital. The manual describes a backlit display, a Capture button that stores live readings so you can watch the assembly instead of the gauge, Bluetooth for test-report apps, and a hook on the back. It runs on four AA batteries and is rated IP57.

Arbiter says the hoses are made from materials suitable for potable water under NSF 61 and FDA guidelines and include a 40-micron filter. Maximum working pressure is 175 psi into the assembly under test, and maximum water temperature is 140°F.

The warranty is five years from the date of manufacture, for the original purchaser. It excludes damage from freezing, and opening the unit beyond the battery compartment voids it. The manual says to always drain water from the gauge after use.

One listing detail to know: the Amazon title says soft case while one bullet says hard shell case.

Best for a dial gauge

Mid-West 845-5

Mid-West Instrument 845-5 5-valve backflow prevention assembly test kit

845-5
$973.94
Check it on Amazon
low stock · price as of Nov 22, 2026, 9:30 AM EST
10Spec scoreHow it’s scored
On a USC Foundation list10
±0.2 psid or better10
Five-valve kit10
Inline hose filters10
175 psi or more working pressure10
Warranty 2 years or more10
Carrying case included10

Pros

  • 4-1/2 in. diaphragm dial, 0–15 psid
  • Built-in 0–200 psig line pressure gauge
  • 90-micron inline filters, cleanable or replaceable
  • 5-year warranty

Cons

  • ±0.2 psid on the descending scale, not ±0.1
  • On USC’s 9th edition acceptable list, not the 10th edition approved list
  • Maximum water temperature 150°F
0–15 psid±0.2 psid5 valves200 psig3.6 lb gauge

Buy it if

You want a proven mechanical dial gauge with no batteries, and your authority accepts kits on the USC acceptable gages list.

Skip it if

Your authority requires a kit on the USC 10th edition approved list; the Mako is the one there.

The 845-5 is the classic dial kit, and I’ve used it. It scored 10.0.

Mid-West’s bulletin describes a diaphragm differential pressure gauge with a 4-1/2 in. dial reading 0–15 psid (0–100 kPa), accurate to ±0.2 psid on the descending scale. Working pressure is 200 psig, and a 1-1/2 in. line pressure gauge reads 0–200 psig.

It’s a five-valve kit with soft-seated brass needle valves that have replaceable seats. Mid-West says 90-micron filters protect the kit from scale and sand, and the filter elements can be cleaned or replaced. The three color-coded hoses are 5 ft long with Schrader 1/4 in. brass couplers, plus a 4 ft clear bleed tube.

The gauge body is glass-reinforced engineering thermoplastic, and the wetted parts are EP elastomers, brass and 316 stainless. The gauge weighs 3.6 lb, and the molded case is 18-1/2 by 9 by 9-3/4 in. with compartments for fittings and tools. Three sets of brass adapter fittings fit standard test cocks.

Mid-West says the 845 is on the acceptable gages lists of both the USC Foundation and CA-NV AWWA. The USC acceptable gages document, dated January 31, 2025, lists Mid-West models 830, 835, 845-2, 845-3 and 845-5 under the Ninth Edition guidelines. That’s a different list from the Tenth Edition approved list.

The bulletin warns that freezing temperatures must be avoided and sets a 150°F maximum. Mid-West also recommends annual accuracy verification of every test kit, calling kits measuring instruments that need routine checks. The warranty is five years.

Mid-West says the gauge can run all known test procedures, including those recommended by ABPA, ASSE, AWWA, CSA, FCCC and HR-USC, NEWWA and UF-TREEO. The whole kit ships at about 11.5 lb, and Mid-West says the design drew on more than 30 years of input from backflow technicians.

Best for a kit with a calibration report

Bac-Flo-5

Five-valve backflow test kit, made in the USA

BAC-FLO-5
See today’s price on Amazon
Check it on Amazon
10Spec scoreHow it’s scored
On a USC Foundation list10
±0.2 psid or better10
Five-valve kit10
Inline hose filters10
175 psi or more working pressure10
Warranty 2 years or more10
Carrying case included10

Pros

  • Calibration report valid for a full year, per Bac-Flo
  • Same gauge specs as the Mid-West 845-5
  • 1/4–3/4 NPT brass adapter set and a 6-in-1 screwdriver
  • 5-year warranty

Cons

  • USC lists it as acceptable (9th edition), not approved (10th)
  • Maximum water temperature 150°F
0–15 psid±0.2 psid5 valves200 psigMade in USA

Buy it if

You want a dial kit that arrives with a year’s calibration report and a full adapter set.

Skip it if

Your authority requires a kit on the USC 10th edition approved list.

The Bac-Flo-5 is a dial kit from a company that also trains backflow testers, and I’ve used it. It scored 10.0.

Its gauge numbers match the Mid-West 845-5 line for line: a 4-1/2 in. diaphragm dial reading 0–15 psid, ±0.2 psid on the descending scale, 200 psig working pressure and a 0–200 psig line gauge. There’s a reason. The USC acceptable gages document lists Bac-Flo-3 and Bac-Flo-5 with a note that they’re private label and manufactured by Mid-West Instruments.

Where it differs is the kit around the gauge. Bac-Flo says it ships with a calibration report valid for a full year, high-pressure color-coded hoses with 90-micron removable brass filters, a 1/4 to 3/4 in. NPT brass adapter set, full-page laminated test procedures and a 6-in-1 Klein stubby screwdriver.

The spec sheet lists soft-seated brass needle valves with replaceable seats, a glass-reinforced thermoplastic body, EP elastomer, brass and 316 stainless wetted parts, three 5 ft hoses with Schrader couplers and a 4 ft clear bleed tube. The padded case measures 18-1/2 by 9 by 9-3/4 in.

A wording note: Bac-Flo’s spec sheet heads itself “approved by USC FCCCHR and CA-NV AWWA”. On the USC Foundation’s own documents, the Bac-Flo-5 appears on the Ninth Edition acceptable gages list, not the Tenth Edition approved list. Check which one your authority asks for.

The maximum temperature is 150°F, and Bac-Flo says freezing temperatures must be avoided. The warranty is five years.

Bac-Flo, based in Boerne, Texas, runs backflow tester certification and renewal courses, and lists the same test procedures as Mid-West: ABPA, ASSE, AWWA, CSA, USC-FCCCHR, NEWWA and UF-TREEO. Shipping weight is about 11.5 lb, and the spec sheet describes a foam padded case with compartments for fittings and tools.

Klein 6-in-1 stubby screwdriver included with the Bac-Flo-5 kit
The Klein 6-in-1 stubby screwdriver Bac-Flo packs with the Bac-Flo-5. Product photo: Amazon

The three side by side

KitReadoutAccuracy (0–15 psid)USC listMax pressureWarrantyScore
Arbiter Mako MK5Digital, backlit±0.1 psid10th edition approved175 psi5 years from manufacture10.0
Mid-West 845-54-1/2 in. dial±0.2 psid (descending)9th edition acceptable200 psig5 years10.0
Bac-Flo-54-1/2 in. dial±0.2 psid (descending)9th edition acceptable (made by Mid-West)200 psig5 years10.0

Approved or acceptable: the two USC lists

ListWhat it isKits named
List of Approved Field Test Kits (10th edition)Kits that passed lab evaluation to the standard in Manual Chapter 10.2Arbiter Mako MK5 (approved Dec 10, 2019)
Acceptable Gages (9th edition)Gages reviewed against the older Section 9 guidelines, before the standard existedIncludes Mid-West 830, 835, 845-2, 845-3, 845-5; Bac-Flo-3, Bac-Flo-5; Watts TKDR, TKDP, TK99D

USC describes a field test kit as a visual indicator that measures the difference between two pressure points, such as the pressure on each side of a check valve.

The USC Foundation for Cross-Connection Control and Hydraulic Research keeps both lists. Its approved list covers kits that completed the lab evaluation in the Tenth Edition of its Manual. The acceptable gages list covers gages it reviewed earlier against the Ninth Edition’s general guidelines.

USC says a kit counts as approved only with the needle valves and hoses its maker supplied; swapping in other hoses or valves invalidates the approval. It also says the local administrative authority decides which kits are acceptable in its area. Call yours before you buy.

Dial or digital

PointDigital (Mako MK5)Dial (845-5, Bac-Flo-5)
Power4 AA batteriesNone
ReadingNumber on a backlit display; Capture button stores itNeedle on a 4-1/2 in. dial
Accuracy±0.1 psid, calibrated in the past 12 months, firmware 12+±0.2 psid descending
Water protectionIP57Not rated
RecordsBluetooth to test-report appsWrite readings by hand

A dial gauge has nothing to charge and nothing to update, and testers have used them for decades. A digital gauge gives you an exact number, holds it with the Capture button, and can send it to an app, but it depends on batteries and firmware.

For fast-moving readings, like a relief valve opening point or a vacuum breaker test, Arbiter says the Capture function lets you watch the assembly rather than the gauge. With a dial, you watch the needle and the relief port at the same time.

Why five valves

ConfigurationValvesExample
Five-valveFive test valves; the Mako is listed as configuration 5 by USCAll three picks
Three-valveTwo ball valves and one needle valve, per WattsWatts TK-9A
Brass valve block inside the Arbiter Mako MK5, with high and low valves and three hose ports
Inside the Mako MK5: the brass valve block and three hose ports. Product photo: Amazon

The USC approved list records each kit’s configuration as its number of needle valves, and lists the Mako MK5 as configuration 5. Arbiter’s manual calls the MK5’s layout an accepted five-valve water flow configuration as prescribed by USC Manual 10. Mid-West and Bac-Flo sell theirs as five-valve kits, and Watts lists two ball valves and one needle valve on the TK-9A.

Buy the configuration your training used and your authority’s procedure expects. Watts’ TK-9A instructions, for example, name its valves A, B and C step by step, while the 845-5 and Bac-Flo-5 ship with their own laminated test procedures.

Calibration and care

ItemWhat the makers say
Accuracy checksMid-West recommends annual accuracy verification of every test kit
Arbiter accuracy figureHolds if calibrated within the past 12 months, firmware 12 or later
Bac-FloShips with a calibration report valid for a full year
FreezingAll three makers say avoid freezing; Arbiter says it voids the warranty
After useArbiter: always drain water from the gauge; Watts: hold the kit vertically to drain gauge and hoses

Mid-West’s letter on annual accuracy verification makes the case plainly: test kits are mechanical measuring instruments exposed to debris, heat, freezing and impacts, the same conditions as the assemblies they test.

Mid-West adds that pressure gauge standards call for regular accuracy checks based on use, that quality systems require every measuring instrument to be under a procedure, and that annual verification shows which kits need recalibration or repair.

Draining the kit after every job is the habit that saves gauges. Water left in a gauge that freezes can damage it, and Arbiter treats freeze damage as abuse outside the warranty.

What a reduced pressure test checks

  1. 1
    Check valve No. 2

    Must be tight against reverse flow.

  2. 2
    Shutoff No. 2

    Tested for tightness after check 2 passes.

  3. 3
    Check valve No. 1

    Must be tight against reverse flow.

  4. 4
    Relief valve

    Must hold the zone at least 2 psi below supply.

  5. 5
    Record the readings

    Opening point and check readings on the report.

  6. 6
    Restore the assembly

    Remove the kit, reopen shutoff No. 2.

Those steps follow the reduced pressure zone procedure in Watts’ TK-9A instructions, which test check valve No. 2, shutoff No. 2, check valve No. 1 and then the relief valve opening point. Your authority may use a different procedure, such as the USC Foundation’s; follow the one it requires.

Testing a backflow assembly for a water authority usually needs a certified tester, not just a kit. For the assemblies themselves, see best backflow preventer.

Why testers use a differential gauge

Reason Watts givesWhat it means on the job
Takes minimum timeFewer steps per assembly
No need to close the inlet ball valveLess chance of knocking pipe scale into the assembly
Only a little water is spilledLess water on the floor
A mercury manometer could cause a pollution hazardNo mercury near drinking water

Watts’ TK-9A instructions recommend a differential pressure gauge over a manometer for the first reduced pressure test, for the four reasons above. All three picks are diaphragm or digital differential gauges reading 0–15 psid, the range those tests use.

The line pressure gauge on the 845-5 and Bac-Flo-5, reading 0–200 psig, is a separate dial. It shows supply pressure, which helps when a reading looks odd and you want to know what the assembly is seeing.

Hoses, filters and colors

KitHosesFiltersCouplers
Arbiter Mako MK5Three, color coded40 micronSupplied with the kit
Mid-West 845-5Three 5 ft, color coded, plus 4 ft clear bleed tube90 micron, cleanableSchrader 1/4 in. brass
Bac-Flo-5Three 5 ft, color coded, plus 4 ft clear bleed tube90 micron, removable brassSchrader 1/4 in. brass
Watts TK-9AThree 3 ft, swivel couplingsNot stated1/4 in. threaded adapters

Watts’ diagrams color the high hose yellow, the low hose white or red and the vent hose blue. Color coding cuts mistakes when you move hoses between test cocks.

Filters keep scale and sand out of the needle valves and gauge. Remember USC’s rule: on an approved kit, replacement hoses or needle valves must be the maker’s own, or the approval no longer holds.

What a double check test checks

  1. 1
    Hook up across check 1

    High to test cock 3, low to test cock 2.

  2. 2
    Bleed the air

    Open the vent valve, then bleed high and low.

  3. 3
    Close shutoff No. 1

    Loosen the low hose until the gauge reads 2 psi.

  4. 4
    Watch the reading

    If it doesn’t drop, check 1 is tight.

  5. 5
    Repeat across check 2

    High to test cock 4, low to test cock 3.

  6. 6
    Restore the assembly

    Remove hoses, return valves to service.

Those steps follow Watts’ double check valve procedure in the TK-9A instructions. Watts adds that an assembly fails both check tests if shutoff No. 2 leaks badly, and gives a separate test for it: if the differential gauge rises above zero, the shutoff must be replaced before the assembly can be tested.

This is where a kit’s accuracy at low readings matters again: the double check test sets a 2 psi differential and watches for a drop, so a gauge that reads true near 2 psid makes the call clearer.

Also checked: Watts TK-9A

KitScoreWhat held it backWhat it does well
Watts TK-9A2.9Not on either USC list; ±2% of 15 psid full scale; three valves; inline filters not stated; 1-year warrantyCompact; tests RP, double check, PVB and SVB assemblies to USC and ASSE 5000; 175 psi; carrying case

The TK-9A is a genuine Watts kit; the Amazon listing’s UPC, 098268022049, matches Watts’ model page. It’s compact and covers every common assembly. But on the checks here it falls short: Watts lists ±2% accuracy of full scale, three test valves, a one-year warranty, and it isn’t on the USC lists, which name the Watts TKDR, TKDP and TK99D instead.

How to choose

If you…Pick
Must use a USC 10th edition approved kitArbiter Mako MK5
Want the tightest stated accuracyArbiter Mako MK5
Want a mechanical dial with no batteriesMid-West 845-5
Want a calibration report in the boxBac-Flo-5
Test in cold weather oftenAny, but drain after every use

Start with your water authority: its list of acceptable kits decides more than any spec. Then choose dial or digital, and plan for an annual calibration whichever you buy. For other testing gear, see best water pressure gauge.

Questions people ask

What is the best backflow test kit?

The Arbiter Mako MK5 is the only kit on the USC Foundation’s approved list, at ±0.1 psid.

Is the Mid-West 845-5 USC approved?

It’s on USC’s 9th edition acceptable gages list, not the 10th edition approved list.

How accurate are backflow test kits?

±0.1 psid for the Mako MK5 and ±0.2 psid for the 845-5 and Bac-Flo-5, per their makers.

How often should a backflow test kit be calibrated?

Mid-West recommends annual accuracy verification; Arbiter’s accuracy figure assumes calibration in the past 12 months.

Who decides which test kits are allowed?

The local administrative authority, per the USC Foundation.

What is a 5-valve backflow test kit?

A kit with five test valves; USC lists approved kits by their number of needle valves.

Can I use other hoses on a USC approved kit?

USC says other hoses or needle valves invalidate the approval.

What warranty do backflow test kits have?

Five years for the Mako MK5, 845-5 and Bac-Flo-5; one year for the Watts TK-9A.

Can a test kit freeze?

Yes; all three makers say avoid freezing and drain the kit after use.

Do I need a license to test backflow preventers?

For reports to a water authority, usually yes; check your state and local rules.

How I pick and score

Why trust me

I’m Isaac Daniels, a licensed journeyman plumber in Georgia (Georgia journeyman plumber license), and I’ve used these picks. Every spec here comes from the makers’ manuals, bulletins and spec sheets and the USC Foundation’s published lists, read on Oct 24, 2026.

How I pick

  • Differential pressure backflow test kits, five-valve configuration.
  • New and in stock on Amazon on Oct 24, 2026.
  • Each scored on the same seven checks below; every pick reaches 7.0.
  • Prices come from Amazon’s API with the time they were read.
Check (pass = 1)Where it comes from
On a USC Foundation list (10th edition approved or 9th edition acceptable)USC documents
Accuracy ±0.2 psid or better from 0 to 15 psidMaker’s sheet or manual
Five-valve configurationMaker’s sheet or USC list
Inline hose filters statedMaker’s sheet or manual
Maximum working pressure 175 psi or moreMaker’s sheet or manual
Warranty 2 years or longerMaker’s sheet or manual
Carrying case includedMaker’s sheet or Amazon listing

Score = checks passed ÷ 7 × 10, rounded half up. It’s the PlumbingPicks spec score, built from published facts. It isn’t a customer rating or an Amazon rating.