Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product.
Match the pump to the job first
Four questions pick the pump: what makes the water, how hot it gets, how high it has to go, and how much room you have.
Central AC or a standard furnace coil
A 1/2 gallon tank pump like the VCMA-20ULS covers most of these. Little Giant rates it to a 20 ft shut-off and 140°F water.
Condensing boiler or high-efficiency furnace
DiversiTech rates the FP-22 for acidic, high-temperature condensate up to 190°F. Little Giant also lists the VCMA series as suitable for condensing furnaces and boilers.
Low drain outlet or a short closet
DiversiTech sells the CP-22LP as a 4-3/8 in. design, with an inlet 1.75 in. off the base.
Ductless mini-split head
A wall head drips slowly and has no room for a tank. DiversiTech’s CVMINI fits inside many wall cassettes and line set covers.
Pump outlet goes up more than 15 ft
Little Giant’s manual says the vertical run shouldn’t pass 75% of the pump’s rated head. Size up before you buy.
No overflow switch wired
A pump without its switch wired can flood when it fails. Little Giant says the switch can shut the equipment down or trip an alarm (not included).
Little Giant VCMA-20ULS: 20 ft with a safety switch
You need a pump next to a furnace, air handler or AC coil, and the outlet goes up no more than about 15 ft.
Skip it if
Your condensate runs hotter than 140°F (get the FP-22) or the drain outlet sits less than 4 in. off the floor (get the CP-22LP).
The VCMA-20ULS is my top pick because it covers the most common job, a furnace or air handler in a basement, closet or garage, with a safety switch already in the box. Little Giant built the VCMA series to move condensate from boilers, furnaces and AC units when gravity drainage isn’t possible.
The numbers from Little Giant’s catalog: a 1/30 hp motor, 1.5 amps at 115 V, and a 1/2 gallon ABS tank. It pumps 80 gallons per hour at 1 ft of lift, 70 at 5 ft and 48 at 10 ft, with a 20 ft shut-off and 8.7 PSI.
The outlet is a 3/8 in. OD barbed fitting with a built-in check valve. That valve stops the water in the line from running back into the tank every time the pump shuts off.
The ULS version comes with the overflow switch, per Little Giant’s order table. Little Giant says it’s dual function, NO and NC, and ships set for equipment shutdown. Two 5 in. leads come off the switch. The listing says the alarm isn’t included and basic wiring knowledge is needed.
There are three 1-1/8 in. inlets, two of them capped, so a furnace and an AC coil can drain into the same tank. Little Giant’s manual says the total inflow can’t exceed what the pump moves, so check that before you tie in a third line.
Little Giant’s catalog lists the VCMA series as suitable for high-efficiency oil and gas condensing furnaces and boilers too. The cap is 140°F. The manual adds one rule for gas furnaces: keep the condensate pH above an average of 3.4 by flushing.
Little Giant sells this pump with tubing as the VCMA-20ULST (554435). That version was low in stock when I checked on Oct 19, so I picked the 554425 and you buy 3/8 in. ID tubing separately.
On the spec score it lands at 8.7, behind the DiversiTech pumps on lift and heat rating. I still put it first for a standard coil: a 20 ft shut-off covers most basement runs, and the check valve and switch come built in.
My call: put this one on most furnace and AC jobs. It has the switch, the check valve and the three inlets, and Little Giant backs it with a 12-month limited warranty, per the manual.
How hot the water can be for each pump
Condensing boilers and furnaces send out warm, acidic water. A pump rated below that temperature wears out early.
Bar length is the maker’s listed maximum water temperature.
From Little Giant’s HVAC catalog 995505, DiversiTech’s FP-22 and CP-22LP product pages, and DiversiTech data sheets DOC32215 and DOC32482, read Oct 19, 2026.
Most AC coils drip cool water, so every pump here handles them. The chart matters for boilers and condensing furnaces. If the equipment manual lists a condensate temperature above 140°F, look at the FP-22, rated to 190°F. DiversiTech’s CP-22LP page lists 160°F.
A pump moves acidic water. It doesn’t neutralize it. If your boiler or furnace manual, or your inspector, calls for a condensate neutralizer before the drain, that’s a separate part that goes in the line.
DiversiTech FP-22: rated for 190°F, acidic condensate
Best for hot, acidic condensate
DiversiTech FP-22
DiversiTech Asurity FP-22 furnace condensate pump, 120 V
You’re draining a condensing boiler, a high-efficiency furnace or anything with condensate hotter than 140°F.
Skip it if
Your inspector requires a UL Listed pump, or you’re draining a plain AC coil. The VCMA-20ULS covers that.
The FP-22 is the pump DiversiTech built for the hard job. DiversiTech says the Asurity FP-22 is designed for acidic and high-temperature applications, with condensate up to 190°F. That’s 50 degrees past the VCMA-20ULS.
Its spec table lists a 1/30 hp motor, 1.9 amps at 120 V, a NEMA 5-15 plug, a 0.5 gallon tank, 126 GPH max flow and a 22 ft lift.
The features follow the job. DiversiTech lists steam-resistant electronics, rubber isolation feet to cut vibration, metal hang tabs, LED indicators, a safety overflow switch, a check valve and a plug protector.
The four inlets each have a built-in P-trap, per DiversiTech. DiversiTech doesn’t say it replaces the traps the furnace or boiler maker calls for, so follow the equipment manual on drain traps.
DiversiTech also marks it A2L Certified. A2L is the safety class for the mildly flammable refrigerants newer systems use, so on an A2L job the pump is one less question.
One line in DiversiTech’s own spec table you should see: UL Listed, No. The CP-22LP lists Yes. If your inspector or the equipment maker requires a UL Listed pump, check before you buy this one.
The Amazon listing says it includes 20 ft of 3/8 in. tubing. DiversiTech’s page doesn’t list what’s in the box, so check the box when it arrives.
A pump rated for acid moves acidic water. It doesn’t change it. If the boiler maker or your local code calls for a neutralizer, plan for one in the line.
My call: on a condensing boiler, this is the pump I’d look at first, because 190°F covers what a 140°F pump can’t. On a plain AC coil it’s more pump than you need.
How high each pump can push water
Makers rate lift as the shut-off height, where flow drops to zero. You want to stay well under it.
Bar length is the maker’s rated lift (DiversiTech) or shut-off height (Little Giant), at 115 to 120 V.
From Little Giant’s HVAC catalog 995505 and DiversiTech’s product pages and data sheets DOC32215 and DOC32482, read Oct 19, 2026.
The CVMINI’s 35 ft looks like a winner, but it’s a mini-split pump that moves a few gallons an hour. Lift and flow trade off. Compare tank pumps with tank pumps.
The number that matters is the vertical rise from the pump to the highest point of the line, usually where it crosses a joist or goes up to a drain. Measure that before you pick a pump, then use the table further down to stay under 75% of the rating.
DiversiTech CP-22LP: a low tank for a low drain
Best where clearance is tight
DiversiTech CP-22LP
DiversiTech Asurity CP-22LP low profile condensate pump, 120 V
The coil or furnace drain outlet sits low, and a standard pump’s inlet would be higher than the drain.
Skip it if
You have room for a full-height pump. The VCMA-20ULS or CP-22T has a bigger tank.
Low clearance isn’t really about fitting a pump under something. It’s about the inlet. The water has to fall into the pump, so the pump’s inlet must sit below the equipment’s drain outlet. A furnace drain a few inches off the floor rules out most tank pumps.
That’s the CP-22LP’s job. DiversiTech sells it as only 4-3/8 in. tall. Its data sheet puts the inlet just 1.75 in. off the base, against 4.4 in. on the standard CP-22.
One detail to plan around: the dimension line on the same sheet lists the low profile at 4.9 in. high. My call: plan for a 5 in. space, not 4-3/8 in.
The rest matches the CP-22. DiversiTech lists a 22 ft lift, a 1/30 hp motor, 1.9 amps at 120 V and 132 GPH max flow. It has vibration-dampening feet and motor mounts, an LED display, a check valve and an overflow switch.
It’s rated hotter than most. DiversiTech’s product page lists condensate up to 160°F. The CP series data sheet lists 140°F continuous duty and 160°F max inlet, and says it’s not for steam or gases over 160°F.
The small height costs tank size. DiversiTech’s page lists a 1/3 gallon reservoir, and the data sheet says 3/8 gallon. Either way it’s smaller than the 1/2 gallon in the full-size pumps, so the pump cycles more often.
Service is easy. DiversiTech lists a removable reservoir and a reversible deck, and the Amazon listing mentions a removable check valve. With four inlets and a reversible deck, you have options for where the drain lines come in.
DiversiTech’s spec table lists it as UL Listed and A2L Certified, which helps if an inspector asks.
My call: if a standard pump’s inlet sits above your drain, buy this one and don’t try to shim the equipment up.
How high you can really run each pump
Little Giant’s VCMA manual says the vertical run shouldn’t pass 75% of the pump’s rated head. Here’s that limit worked out.
Pump
Rated lift
75% limit
Where the rule comes from
Little Giant VCMA-15ULS
15 ft
11 ft 3 in.
Little Giant manual
Little Giant VCMA-20ULS
20 ft
15 ft
Little Giant manual
Little Giant VCL-24ULS
24 ft
18 ft
Same margin, my call
Little Giant 1-ABS
10 ft
7 ft 6 in.
Same margin, my call
DiversiTech FP-22, CP-22LP, CP-22T
22 ft
16 ft 6 in.
Same margin, my call
DiversiTech CVMINI
35 ft
26 ft 3 in.
Same margin, my call
Rated lifts from Little Giant’s HVAC catalog 995505 and DiversiTech’s product pages. The 75% rule is from Little Giant’s VCMA owner’s manual 998086, read Oct 19, 2026. DiversiTech doesn’t publish a margin, so the DiversiTech rows apply Little Giant’s rule as my call.
Why leave a margin? Flow falls fast as lift climbs. Little Giant’s table for the VCMA-20ULS goes from 80 GPH at 1 ft to 48 GPH at 10 ft and zero at 20 ft. A pump run near its shut-off barely moves water, runs longer and wears out sooner.
The manual also says how to run the line. Go straight up, slope down slightly at the top, then drop to a drain at or below the bottom of the pump. Little Giant says that makes a siphon that helps the pump. If you can’t slope it, make an inverted “U” at the high point.
DiversiTech CVMINI: a small pump for a ductless head
A different kind of pump from the six tank pumps above, so it isn’t scored against them.
DiversiTech CVMINI ClearVue mini ductless system pump. Product photo: Amazon.
A ductless wall head makes a slow drip, and it usually hangs on an outside wall with nowhere for a tank. DiversiTech built the CVMINI for that. Its data sheet says it’s compact enough to fit inside many wall cassette units and line set covers.
The pump body is small. DiversiTech lists it at 3.38 x 1.57 x 1.84 in. and 1.1 lb. It runs on 120 or 240 V at 1.0 amp, so it works with either supply.
It’s built for small flow. DiversiTech lists 500 mL per minute at zero head, about 8 gallons an hour, and a max rated inlet of 100 mL per minute. That’s plenty for a wall head. It’s not enough for a furnace coil.
The trade for low flow is lift. DiversiTech rates it up to 35 ft, with variable lift that adjusts to how fast water comes in, per the listing.
There’s no float. DiversiTech uses a floatless sensor, and the listing says that avoids sunken or fouled floats. The overflow switch is built in and rated 5 A at 230 VAC, per the data sheet.
Where it does well
What to watch
Fits inside many wall cassettes and line set covers
Low flow, about 8 gallons an hour
Up to 35 ft of lift
Must be primed
No float to stick
Not for a furnace or central AC
Works on 120 or 240 V
Built-in overflow switch
Two install rules from the data sheet. Suction lift tops out at 6.5 ft and works best at 3 ft, so mount the pump close below the drain. And it must be primed before it runs.
DiversiTech lists noise at 19 dB at low flow and 28.4 dB at full flow. My call: on a bedroom wall, that matters more than the lift number.
In the box, per the data sheet: tubing, vent tubing, hook-and-loop strips, wire ties and 6 ft cables. That covers most installs without a store run.
My call: for a mini-split head, this is the pump to buy. For anything with a drain pan and a big coil, pick a tank pump.
How much water each Little Giant pump moves at 5 ft
Little Giant publishes flow at set heights, so its pumps can be compared at the same lift.
Gallons per hour at 5 ft of lift, from Little Giant’s catalog tables. DiversiTech lists max flow only (126 to 132 GPH), so its pumps are left off.
From Little Giant’s HVAC catalog 995505, read Oct 19, 2026.
Flow matters when more than one unit drains into one pump, or when a big coil sweats hard on a humid day. Little Giant’s manual says inflow that meets or beats the pump’s output needs a bigger pump.
For one furnace or one AC coil, 70 GPH at 5 ft is a lot of headroom. The VCL-24ULS is for the job where two or three units share a pump.
Little Giant VCL-24ULS: a 1 gallon tank and 270 GPH
Two or three units drain to one pump, or one large system makes more water than a 1/2 gallon pump keeps up with.
Skip it if
Your condensate runs above 120°F. The FP-22 is rated to 190°F.
The VCL-24ULS is the big tank pump in Little Giant’s line. The catalog lists a 1 gallon tank and a 1/18 hp motor, 2.5 amps and 148 watts at 115 V.
Its flow is in a different class. Little Giant lists 270 gallons per hour at 1 ft, 260 at 3 ft, 250 at 5 ft and 210 at 9 ft, with a 24 ft shut-off and 10.4 PSI. That’s more than three times the VCMA-20ULS at 5 ft.
A bigger tank means fewer starts. With twice the volume of a 1/2 gallon pump, it runs less often on the same inflow. My call: on a commercial unit or a shared drain, that’s the reason to buy it.
The build is heavier too. The catalog lists an ABS tank and pump housing, a galvanized steel tank cover, a stainless steel motor shaft and a polypropylene impeller. It weighs 8.2 lb.
The overflow switch works like the VCMA’s. Little Giant says it’s dual function, NO and NC, and ships set for equipment shutdown. The listing says it can shut down a furnace, AC or dehumidifier, or run an alarm that’s sold separately.
Watch the outlet setup. A 3/8 in. barbed adapter comes installed, and Little Giant puts an optional check valve adapter for 3/8 in. vinyl tubing in the box. A check valve for 3/8 in. copper tube is sold separately as part 599063. My call: install the check valve adapter.
The motor is thermally protected and fan cooled, and the 6 ft cord has a grounded 3-prong plug, per the catalog.
It has two 1-1/8 in. inlets, one fewer than the VCMA series. Little Giant’s catalog lists it as suitable for condensing furnaces and boilers, but the cap is 120°F, the lowest of the tank pumps here.
Little Giant 1-ABS: a pump that sits in the drain pan
A different kind of pump from the six tank pumps above, so it isn’t scored against them.
Little Giant 1-ABS shallow pan condensate pump, 115 V (550521). Product photo: Amazon.
The 1-ABS doesn’t have a tank. It sits in the drain pan. Little Giant says its low on and off levels make it a fit for in-pan condensate removal, and the listing names ceiling-mounted AC units, dehumidifiers and portable air conditioners.
The levels are the point. Little Giant’s catalog says it turns on at 1-3/4 in. of water and off at 1-1/4 in., and that it will work in most standard condensate drain pans.
It moves water fast for a small pump. The catalog lists 205 gallons per hour at 1 ft, 180 at 3 ft and 145 at 5 ft, with a 10 ft shut-off and 4.3 PSI. It draws 1.1 amps and 70 watts at 115 V.
The build is metal, not plastic. Little Giant lists an epoxy-coated cast aluminum housing and cover, an oil-filled motor and bearings that need no lubrication over the pump’s life. A removable inlet screen keeps debris out.
Plan your tubing. It comes with a 90° 1/4 in. MNPT adapter for 1/2 in. ID vinyl tubing. That’s a bigger line than the 3/8 in. tubing the tank pumps use.
Where it does well
What to watch
Turns on at 1-3/4 in. of water
No overflow switch listed
205 GPH at 1 ft
10 ft shut-off
Epoxy-coated cast aluminum housing
Uses 1/2 in. ID tubing, not 3/8 in.
Removable inlet screen
9 ft cord
What it doesn’t have: Little Giant’s catalog and the listing don’t list an overflow switch, and the 550521 has no tank. Little Giant sells a version with a tank as 550522.
My call: since there’s no switch, put a leak detector or a pan float switch in the pan too. Our water leak detector guide covers that backup.
The water limit is 120°F intermittent, so keep it on AC and dehumidifier water, not boiler condensate.
It weighs 4.11 lb, and its 9 ft cord is longer than the 6 ft cords on the Little Giant tank pumps, per the catalog. That extra reach helps when the outlet isn’t right next to the pan.
Every pump fails sometime. The switch decides whether a failure means a shut-off furnace or a wet ceiling.
Pump
Overflow switch
What it can do
Little Giant VCMA-20ULS, VCMA-15ULS
Yes, NO and NC
Ships set to shut the equipment down; can be set to trip an alarm or relay
Little Giant VCL-24ULS
Yes, NO and NC
Ships set to shut the equipment down; alarm sold separately
DiversiTech CP-22LP, CP-22T
Yes
Two terminals for air-handler shutdown, 4 ft leads included
DiversiTech FP-22
Yes
Safety overflow switch, per DiversiTech
DiversiTech CVMINI
Yes
Built in, rated 5 A at 230 VAC
Little Giant 1-ABS (550521)
Not listed
Add a pan switch or leak detector
From Little Giant’s HVAC catalog 995505 and VCMA owner’s manual 998086, and DiversiTech’s FP-22 page and data sheets DOC32215 and DOC32482, read Oct 19, 2026.
Little Giant’s manual explains the shutdown setup: when the water gets too high, the switch opens the thermostat circuit and the equipment stops making condensate. It goes on a Class II low-voltage circuit, and the manual says to keep its two black leads away from line voltage.
My call: wire the shutdown. A furnace that stops on a full pump gets noticed the same day. A switch left in the box protects nothing.
Little Giant VCMA-15ULS: the smaller VCMA for a short run
The drain is close, like a floor drain, laundry standpipe or sink tailpiece a few feet away, and the vertical rise is under about 11 ft.
Skip it if
The line goes up to a ceiling or across a long run. Step up to the VCMA-20ULS.
The VCMA-15ULS is the VCMA-20’s smaller sibling. It shares the 1/2 gallon tank, the three 1-1/8 in. inlets, the 3/8 in. barbed outlet with its built-in check valve, and the overflow switch, per Little Giant’s catalog.
The motor is what changes. Little Giant lists a 1/50 hp motor at 1 amp and 60 watts, against 1/30 hp and 1.5 amps on the VCMA-20ULS.
Less motor means less lift. The catalog lists 65 gallons per hour at 1 ft, 50 at 5 ft and 25 at 10 ft, with a 15 ft shut-off and 6.5 PSI. Using Little Giant’s 75% rule, keep the vertical run under 11 ft 3 in.
That fits a lot of real jobs. A basement furnace that drains up and over to a laundry standpipe a few feet away doesn’t need 20 ft of lift. The 15 does that job and draws less power doing it.
Everything else matches. Little Giant lists 140°F max water, a 6 ft cord, built-in wall mount tabs and the same note that the VCMA series suits condensing furnaces and boilers. The listing says it’s CSA certified to US and Canadian standards.
The overflow switch is the same dual NO and NC switch, shipped set for equipment shutdown. The alarm isn’t included, per the listing.
It weighs 4.4 lb. Like the 20, it ships with a float locking tab for transport, and Little Giant’s catalog says to remove it at installation. Check for it before you plug the pump in.
Which VCMA? Measure the rise first. If the highest point of the line is less than about 11 ft above the pump, the 15 works. If it’s anywhere near that, my call is to buy the 20 and have margin.
How to install a condensate pump
These steps come from Little Giant’s VCMA owner’s manual. Check your own pump’s manual for its details.
1
Flush the AC first
Run the AC through a few cycles and catch the water in a bucket. The manual says that flushes out leftover oils.
2
Set it level, below the drain
Mount it level, with the inlet below the coil drain. A pump that isn’t level may not switch on. It can hang on the wall tabs.
3
Pull the shipping insert
Remove the cardboard insert before use. The manual warns the pump will overflow if you leave it in.
4
Run the drain lines in
Cut drain pipes at 45°, so they can’t seal against the tank floor, and run them 1 to 3 in. into the inlets.
5
Route the outlet up first
Use tubing no bigger than 3/8 in. ID, run it straight up, and stay under 75% of the pump’s rated head.
6
Wire the safety switch
Wire the overflow switch into the low-voltage thermostat circuit to shut the equipment down.
7
Plug it in on its own circuit
Not on a fan or anything that cycles. Use GFCI where code requires it, and no extension cord.
From Little Giant’s VCMA owner’s manual 998086 (Rev 002, 03/20), read Oct 19, 2026.
Two more rules from the same manual: the VCMA is for indoor use only, and it’s not meant to go inside an air plenum. Little Giant sells a separate plenum-rated pump, the VCCA-20-P, listed to UL 2043.
Where the line ends matters too. Run it to a drain that’s allowed in your area, like a standpipe, floor drain or tailpiece. If you’re not sure, our condensate drain line guide covers the pipe side.
DiversiTech CP-22T: the full-size CP-22 with 20 ft of tubing
Best kit with tubing in the box
DiversiTech CP-22T
Condensate pump with 20 ft of 3/8 in. tubing, 120 V
You want everything for a standard furnace or AC pump job in one box, including the tubing.
Skip it if
The drain outlet is low (get the CP-22LP) or the condensate runs hot (get the FP-22).
The CP-22T is DiversiTech’s standard CP-22 sold with tubing. DiversiTech’s data sheet says the CP-22 is available with 20 ft of 3/8 in. tubing, and the listing names the CP-22T with a 22 ft lift and 20 ft of tubing.
DiversiTech says the CP-22 series beats the 20 ft industry standard lift by 2 ft. Flow at zero head is 1.6 gallons per minute, about 96 gallons per hour, and it draws 1.9 amps at 120 V.
The tank holds 1/2 gallon, the same as the Little Giant VCMA pumps. DiversiTech lists the CP-22 at 11.8 x 5.9 x 6.7 in. and 5 lb, with the inlet 4.4 in. off the base.
The feature list is long for a standard pump. DiversiTech lists vibration-dampening feet and motor mounts, metal mounting tabs, four inlet holes with three covers, LED indicators, a float switch and a duckbill-style check valve.
Safety wiring is ready. The data sheet says two terminals are provided for air-handler shutdown, and 4 ft remote shutoff leads with insulated terminals come in the box.
DiversiTech says every one of its condensate pumps is computer tested to check performance at all pumping levels. The CP series also comes in 230 V, per the data sheet. This listing is the 120 V model.
Temperature is where it’s ordinary. DiversiTech rates the CP series for 140°F continuous duty, 160°F max inlet, and says it’s not for steam or gases over 160°F.
The tubing is the reason for this pick. 20 ft of 3/8 in. tubing covers a lot of runs, but measure yours from the pump, up and over, to the drain first.
My call: if you want one box for a standard AC or furnace job, this is it. If you already have tubing, the VCMA-20ULS does the same job with a 20 ft shut-off.
How to keep a condensate pump working
Little Giant says to inspect and test the pump every six months. Here’s what that check covers.
Check
What to do
What it prevents
Float
Clean the float. A dirty float is too heavy to rise
Pump never turns on
Check valve
Backwash the check valve
Water running back into the tank
Tank
Clean it with mild soap and water
Slime that clogs the inlet
Test run
Pour water in and watch it pump out
Finding a dead pump on a wet floor
Safety switch
Lift the overflow float and confirm the equipment stops
A switch that never trips
Level
Confirm the pump still sits level
A pump that won’t switch on
From Little Giant’s VCMA owner’s manual 998086, maintenance and troubleshooting sections, read Oct 19, 2026. The safety switch test is my call.
Little Giant’s troubleshooting list starts with two causes that need no new parts: a dirty float that’s too heavy to rise, and a pump that isn’t level. Clean and level the pump before you replace it.
My call: do the check every spring and fall, when the AC or the furnace starts its season, so the six-month habit is tied to something you already notice.
The eight picks side by side
Pick
Spec score
Best for
Lift
Max temp
Tank
Switch
Little Giant VCMA-20ULS
8.7
Most furnaces and AC
20 ft
140°F
1/2 gal.
Yes
DiversiTech FP-22
9.6
Hot, acidic condensate
22 ft
190°F
0.5 gal.
Yes
DiversiTech CP-22LP
8.9
Low drain outlet
22 ft
140°F (160°F inlet)
1/3 to 3/8 gal.
Yes
Little Giant VCL-24ULS
8.0
Big inflow
24 ft
120°F
1 gal.
Yes
Little Giant VCMA-15ULS
8.1
Short lift
15 ft
140°F
1/2 gal.
Yes
DiversiTech CP-22T
9.3
Kit with tubing
22 ft
140°F (160°F inlet)
1/2 gal.
Yes
From Little Giant’s HVAC catalog 995505, and DiversiTech’s product pages and data sheets, read Oct 19, 2026. Lift is the maker’s shut-off or rated lift. All eight pumps on this page were new and in stock when re-checked Oct 22, 2026, 6:20 PM EDT.
How to choose a condensate pump
If you…
Get
Why
Drain one furnace or AC coil
Little Giant VCMA-20ULS
20 ft, switch, check valve
Drain a condensing boiler
DiversiTech FP-22
Rated to 190°F, acidic water
Have a drain outlet near the floor
DiversiTech CP-22LP
Inlet 1.75 in. off the base
Drain a ductless wall head
DiversiTech CVMINI
Fits many line set covers
Tie two or three units into one pump
Little Giant VCL-24ULS
1 gallon tank, 250 GPH at 5 ft
Pump straight out of a shallow pan
Little Giant 1-ABS
Turns on at 1-3/4 in.
Run a few feet to a floor drain
Little Giant VCMA-15ULS
Same build, smaller motor
Want tubing in the box
DiversiTech CP-22T
20 ft of 3/8 in. tubing
Start with the water. A furnace coil, an AC coil and a dehumidifier make cool water. A condensing boiler or high-efficiency furnace makes warm, acidic water, and that narrows the list to pumps rated for it.
Then measure. Note how far the drain outlet sits off the floor, and how high the line has to climb. Those two numbers pick between a low-profile pump, a 15 ft pump and a 20 ft pump. If the water goes to a basement pit, our sump pump guide covers that side.
Questions people ask
What is the most reliable condensate pump?
Neither maker publishes failure rates, so nobody can rank pumps on reliability from facts. My pick is the Little Giant VCMA-20ULS. What Little Giant does publish is how to keep one working: stay under 75% of rated lift, set it level and inspect it every six months.
Does it matter what condensate pump I use?
Yes. Water temperature, lift, flow, the drain outlet height and the safety switch all differ. A 120°F pump on a condensing boiler, or a 15 ft pump pushing 14 ft up, is the wrong pump for the job.
What is the life expectancy of a condensate pump?
Makers don’t publish a lifespan. Little Giant gives the VCMA series a 12-month limited warranty and says to inspect and test it every six months.
Which condensate pump brand should I buy?
Little Giant and DiversiTech both publish full specs, manuals and data sheets, which is why every pick here comes from them. Pick the model by job, then check it was sold new and in stock.
Can a condensate pump handle furnace condensate?
Yes, if it’s rated for it. Little Giant lists the VCMA series as suitable for condensing furnaces and boilers up to 140°F. DiversiTech rates the FP-22 for acidic condensate up to 190°F.
Do I need a condensate pump with a safety switch?
My call: yes. Wired to the thermostat circuit, the switch shuts the equipment down when the tank backs up, so a dead pump doesn’t overflow.
Can I plug a condensate pump into an extension cord?
Little Giant’s manual says no. Plug it into its own outlet, not one shared with a fan or anything that cycles, and use GFCI where code requires it.
Why won’t my condensate pump turn on?
Little Giant’s troubleshooting list starts with a pump that isn’t level and a dirty float that’s too heavy to rise. On a new install, check that the cardboard shipping insert came out.
What size tubing does a condensate pump use?
Most tank pumps here use 3/8 in. tubing, and Little Giant’s VCMA manual says no bigger than 3/8 in. ID. The 1-ABS uses 1/2 in. ID tubing on its 90° adapter.
Can a condensate pump go in an air plenum?
Not the VCMA. Little Giant’s manual says it’s for indoor use and not for installation inside an air plenum. Little Giant sells the VCCA-20-P as a plenum-rated pump, listed to UL 2043.
How I picked these
Why trust me
I’m Isaac Daniels, a licensed journeyman plumber in Georgia (license #JP507711). These picks come from what Little Giant and DiversiTech publish, read the same day, matched to the equipment, the water temperature and the lift you need.
How I pick
One pick per job, so each pump does something the others don’t.
Facts from the maker’s catalog, product pages, data sheets and owner’s manual. Anything not stated is marked “Not listed”.
Genuine branded pumps, new and in stock when re-checked Oct 22, 2026, 6:20 PM EDT. Prices read from Amazon with the time shown, never typed in.
One spec score for the six tank pumps, worked out below. The mini-split and pan pumps do a different job, so they sit in their own sections without a score.
The spec score, check by check
Each check scores 0 to 10. Lift and water temperature count 30% each, tank size and the check valve 20% each. It’s my score from Little Giant’s and DiversiTech’s published figures, not a customer rating or a bench test.
The CP-22LP and CP-22T get the same temperature mark: DiversiTech’s CP series sheet rates both for 140°F continuous and a 160°F inlet limit, even though the CP-22LP page says 160°F. The FP-22 leads on its 190°F rating; the VCL-24ULS loses points for its 120°F cap and a check valve you fit yourself, and wins them back with the 1 gallon tank.
Check (weight)
How it’s scored
Lift (30%)
The maker’s rated lift or shut-off height: 10 for 22 ft or more; 9 for 20 ft; 7 for 15 ft
Hot condensate (30%)
The maker’s water temperature rating: 10 for 190°F; 9 for 140°F continuous with a 160°F inlet limit; 8 for 140°F; 6 for 120°F
Tank size (⅕)
Reservoir size, because a bigger tank cycles less: 10 for 1 gallon; 8 for 1/2 gallon; 6 for 1/3 to 3/8 gallon
Check valve (⅕)
10 when a check valve comes installed; 6 when it’s an adapter in the box you fit yourself
Total
Weighted average of the checks, to one decimal
Pick
Lift
Hot condensate
Tank size
Check valve
Score
Little Giant VCMA-20ULS
9
8
8
10
8.7
DiversiTech FP-22
10
10
8
10
9.6
DiversiTech CP-22LP
10
9
6
10
8.9
Little Giant VCL-24ULS
10
6
10
6
8.0
Little Giant VCMA-15ULS
7
8
8
10
8.1
DiversiTech CP-22T
10
9
8
10
9.3
Sources
Little Giant HVAC/R condensate pump catalog 995505 (VCMA-15, VCMA-20, VCL-24, VCCA-20 and 1-ABS specifications and performance tables): littlegiant.com, read Oct 19, 2026.
Little Giant VCMA-20 product page (features, order information, performance): littlegiant.com, read Oct 19, 2026.
Little Giant VCMA series owner’s manual 998086, Rev 002 03/20 (installation, wiring, maintenance, troubleshooting, warranty): littlegiant.com, read Oct 19, 2026.
DiversiTech Asurity FP-22 and CP-22LP product pages (features and specifications): diversitech.com, read Oct 19, 2026.
DiversiTech CP Series condensate pumps technical data sheet DOC32215: diversitech.com, read Oct 19, 2026.
DiversiTech CVMINI technical data sheet DOC32482: diversitech.com, read Oct 19, 2026.
Amazon listing text for each pick (features and included parts), read Oct 19, 2026.
Google results for “best condensate pump” (top results and People also ask), read Oct 19, 2026.
CPSC recalls: searched for Little Giant, DiversiTech, Franklin Electric and “condensate pump” on Oct 19, 2026. None for these products.
Amazon product data (prices, sellers, stock, photos), refreshed daily; each price shows the time it was read.
Amazon listings for every pump named on this page: new, in-stock offers and image URLs, re-read Oct 22, 2026, 6:20 PM EDT.
U.S. Consumer Product Safety Commission recall search for Little Giant, DiversiTech and Franklin Electric (saferproducts.gov), Oct 22, 2026, 6:20 PM EDT: none for condensate pumps (hits cover ladders, 2004 cooler pumps, and Franklin’s fuel, spa and pump-controller products).