Best gas tankless water heater
For the best gas tankless water heater, I start with Rinnai RX160iN. I choose RXP160iN for planned recirculation and RX130iN for smaller winter demand.
As an Amazon Associate I earn from qualifying purchases. How this site earns
Updated November 15, 2026

The short answer
Choose Rinnai RX160iN when winter demand fits its curve. Pick RXP160iN for planned recirculation, or RX130iN for smaller demand. Have a qualified installer confirm capacity, gas supply and venting before purchase.

Find your heater fit
This finder cannot replace measured demand, the exact model curve or an in-person installation check. The rounded curve readings leave no allowance for site changes.
The gas tankless picks
RX160iN and RXP160iN share a 160,000 BTU/h maximum input. RXP160iN adds an internal pump; RX130iN suits a smaller checked load. Choose by the winter curve and the return-pipe layout. [1]

Rinnai RX160iN

Rinnai RXP160iN

Rinnai RX130iN
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product.
The RXP160 internal pump can reduce distribution delays with an approved return layout. It does not increase burner capacity. RX160 and RXP160 both list a 160,000 BTU/h maximum input. [1]
Rinnai RX160iN

Prices and availability are accurate as of the time shown and may change.
Pros
- 160,000 BTU/h maximum input
- 0.97 UEF in the RX specification
- 9.0 GPM maximum in the RX sheet
- Indoor or approved outdoor configuration
Cons
- No built-in recirculation pump
- Needs a compliant condensate drain
- Winter output falls below maximum flow
Buy it if
Your winter-demand calculation fits the RX160 curve and the house does not need a built-in pump.
Skip it if
Your demand exceeds its curve, or your return layout calls for internal-pump recirculation.
The RX160iN is my starting pick for a whole-house installation where the winter load fits and an internal pump is unnecessary. Rinnai’s RX specification lists 15,000 to 160,000 BTU/h input, 0.97 UEF and a 9.0 GPM maximum. Those are model-specific figures, rather than a family-wide maximum transferred to every heater. [1]
At an 80°F temperature rise, the RX160 curve shows about 4.0 GPM when rounded to roughly 0.5 GPM. The example below needs 4.25 GPM for two assumed showers plus a hot-only tap. That exceeds this approximate output, so reduce overlapping use or have a professional assess a different capacity. [calculation]
The base RX160 has no internal recirculation pump. A short pipe run with an acceptable wait may not need one. If your problem is a long wait at a distant bathroom, identify the return route first. A larger burner does not remove cooled water already sitting between the heater and that bathroom.
Rinnai’s sheet allows indoor installation or outdoor installation with its approved outdoor vent cap. It lists direct-vent and room-air arrangements, subject to the installation manual. Your installer must select the permitted materials and route. An old tank heater’s vent cannot be approved simply because it reaches the same outside wall.
The RX160 also needs a compliant condensate drain and the specified 120 VAC, 60 Hz supply. Keep the condensate path separate from pressure relief discharge. Outdoor placement still needs a freeze plan for exposed pipes and drains. The cabinet’s protective functions do not establish protection for every external valve. [1]
My call: choose the RX160 after the winter-demand and installation checks pass. Its larger burner gives more output than the RX130 at the same rise, but the extra capacity is useful only for demand the household actually has. Leave gas setup and commissioning to a qualified professional under Rinnai’s instructions.
Sources: Rinnai RX sheet, RXP sheet, installation manual.
The tradeoff: There is no built-in recirculation pump; confirm acceptable wait times and winter capacity.
Rinnai RXP160iN

Prices and availability are accurate as of the time shown and may change.
Pros
- Built-in recirculation pump
- 160,000 BTU/h maximum input
- 0.97 UEF in the RXP specification
- Dedicated-return and crossover layouts documented
Cons
- Does not cover the combined cold-inlet example
- Pump needs a suitable return route
- Amazon listing does not itemize carton contents
Buy it if
The RXP160 curve covers your actual load and a qualified installer has designed the recirculation return path.
Skip it if
Your demand exceeds the RXP160 curve, or you have no use for a recirculation loop.
Pick the RXP160iN when distribution delay is the problem and its burner meets the household’s demand. Rinnai’s RXP sheet lists 15,000 to 160,000 BTU/h input, 0.97 UEF and 9.0 GPM maximum flow. The internal pump distinguishes it from the base RX160, whose maximum input and UEF match these figures. [2]
A built-in pump needs a return path. Rinnai describes a dedicated return line or a crossover arrangement with a thermal bypass valve. Have the installer identify the route and served fixtures on the plumbing plan. A bathroom beyond the circulating loop can still have a wait even when the pump is operating correctly.
Rinnai’s RXP specification lists the heater, wall mounting bracket, vent screens, screws and thermal bypass valve as included contents. That is the manufacturer’s package description. The Amazon listing does not itemize the carton, so seller-specific inclusion of those loose parts is unverified. The pump itself is part of the RXP model.
Smart-Circ learns hot-water use patterns to activate recirculation. Dedicated-return and crossover modes have different setup requirements in the manual. Ask for the selected mode and control method in the handover notes. A Wi-Fi capability claim does not establish that an optional remote-control module is included with this Amazon offer.
At an 80°F rise, the RXP160 sheet’s curve is about 4.0 GPM, rounded to roughly 0.5 GPM. That covers the illustrative 3.25 GPM two-shower demand before site adjustments, but falls below the example’s 4.25 GPM demand with an added tap. A pump cannot fill that heating-capacity gap. [calculation]
My call: use the RXP160 for a planned recirculation system whose winter load fits its curve. Check indoor venting or the approved outdoor configuration, plus condensate and freeze protection. Choose the pump for the pipe layout and the burner for the measured load. Both decisions need to pass before the heater is selected.
Sources: Rinnai RX sheet, RXP sheet, installation manual.
The tradeoff: The built-in pump needs a suitable return path and adds no burner capacity.
Rinnai RX130iN

Prices and availability are accurate as of the time shown and may change.
Pros
- 130,000 BTU/h maximum input
- 0.97 UEF in the RX specification
- Same listed cabinet dimensions as RX160
- Indoor or approved outdoor configuration
Cons
- Lower winter output than the other picks
- No internal recirculation pump
- Not enough for the cold-inlet two-shower example
Buy it if
A smaller measured simultaneous load fits the RX130 curve at your winter temperature rise.
Skip it if
Your required load resembles the two-shower cold-inlet example, or needs an internal pump.
The RX130iN is the smaller-demand pick, with 15,000 to 130,000 BTU/h input, 0.97 UEF and a 7.1 GPM maximum in Rinnai’s RX sheet. It is useful when the actual simultaneous load is modest. A small floor plan alone does not establish that load; a single high-flow tub can change the sizing decision. [1]
The RX130 curve shows about 3.0 GPM at an 80°F rise, rounded to roughly 0.5 GPM. My two-shower example needs 3.25 GPM of hot water under those conditions. Treat that as insufficient on this approximate comparison. The 7.1 GPM maximum is not evidence that the same two showers fit in winter. [calculation] [1]
For a household that uses one fixture at a time, build a separate demand worksheet rather than borrowing the two-shower result. Measure the fixture flow and establish the coldest inlet temperature. A warm-weather test at the kitchen sink does not describe the burner load of a winter shower with a running hot-water tap.
The RX130 is not physically smaller than the RX160 in the specification table. Both use the listed 18.5-inch width, 25.8-inch height and 11.4-inch depth. Selecting the lower input does not solve a wall-clearance problem. Service access, vent routing and a usable condensate path remain part of the installation assessment. [1]
Like the base RX160, the RX130 has no internal recirculation pump. An acceptable wait on a short distribution run may suit that arrangement. A distant fixture with a planned return loop raises a separate pump question. Do not trade away required winter output just to match a smaller input number.
My call: choose RX130 only after its own curve passes the household’s demand check. Rinnai allows indoor or approved outdoor installation, with the required vent arrangement and electrical supply. A qualified installer must still assess gas sizing and freeze protection. Lower burner input changes the supply assessment; it does not remove professional installation requirements.
Sources: Rinnai RX sheet, RXP sheet, installation manual.
The tradeoff: There is no built-in recirculation pump; confirm acceptable wait times and winter capacity.
Compare the three picks
The RX160 and RXP160 have the same maximum input. The RXP160 provides an internal pump; RX130 serves a smaller checked load. These are different jobs, rather than interchangeable bathroom-count ratings.
| Heater and use | Maximum input | UEF | Pump and trade-off | Maximum flow in maker sheet | Buy link |
|---|---|---|---|---|---|
Rinnai RX160iNWhole-house use without a pump | 160,000 BTU/h [1] | 0.97 [1] | Same input as RXP160 No internal pump | 9.0 GPM [1] | RX160 on Amazon |
Rinnai RXP160iNPlanned recirculation | 160,000 BTU/h [1] | 0.97 [1] | Internal pump No burner-capacity gain over RX160 | 9.0 GPM [1] | RXP160 on Amazon |
Rinnai RX130iNSmaller demand | 130,000 BTU/h [1] | 0.97 [1] | Smaller-load option Lowest winter output here; no internal pump | 7.1 GPM [1] | RX130 on Amazon |
Sources: RX specifications and curves, RXP specifications and curves, installation requirements. Sizing examples use the stated assumptions.
Maximum input is fuel energy entering the appliance. UEF is a standardized efficiency metric. Use the plotted model-specific curve for winter output rather than multiplying these two figures.
Will this heater fit your replacement?
Use this matrix before choosing an RX or RXP. A stop condition means the installation needs an answer before the purchase, even when the heater itself appears suitable.
| Check | RX160iN / RX130iN | RXP160iN | Stop until this is answered |
|---|---|---|---|
| Winter capacity | Use the exact RX160 or RX130 curve at the required rise | Use RXP curve at the required rise | Measured simultaneous hot-water demand exceeds the applicable curve, or curve selection is unresolved |
| Recirculation | No built-in pump | Internal pump; return arrangement still needed | Nobody has identified the return path or compatible control method |
| Indoor vent | Approved system in RX/RXP manual | Approved system in RX/RXP manual | Old vent material, route or termination has not been checked against this heater |
| Outdoor placement | Approved outdoor configuration required | Approved outdoor configuration required | Cap, termination clearances or freeze plan are missing |
| Condensate | Compliant separate drain route | Compliant separate drain route | No approved disposal route or protection for exposed drain sections |
| Electric power | 120 VAC, 60 Hz [1] | 120 VAC, 60 Hz [1] | Grounded supply and power-loss freeze plan are unresolved |
| Service and water | Water-quality check and service access | Water-quality check and service access | No access to isolate/service the unit, or water is outside maker limits |
Sources: RX specifications and curves, RXP specifications and curves, installation requirements. Sizing examples use the stated assumptions.
A tank-to-tankless replacement often changes the venting job. Do not assume a tank heater’s existing connector, chimney route or combustion-air supply is approved for an RX. Ask for the proposed intake and exhaust system by name, not merely its pipe diameter.
An existing tankless installation also needs a model-specific check. A wall bracket and familiar-looking connections do not establish compatibility with the RX or RXP. The manual’s requirements for the new appliance remain the deciding reference even when the old unit was made by Rinnai.
The non-pump model makes sense once winter capacity and installation checks pass. A short distribution run may give its lack of a built-in pump little practical downside.
Ask the installer to mark the return pipe or approved crossover point on the plumbing plan and identify the control mode.
Rinnai requires trained, qualified installation. Leave fuel setup, combustion checks and vent approval to that professional; do not adjust the internal gas valve.
How much hot water will it supply in winter?
Temperature rise is the heater outlet temperature minus the incoming water temperature. The same house asks more of the burner when its inlet water gets colder.
Rinnai’s RX specification 100000883 plots separate RX160 and RX130 curves; RXP specification 100000884 plots RXP160. The readings below are rounded to roughly 0.5 GPM from those model lines. They are approximate graph readings, not output calculated from burner input or UEF. [calculation]
Both sheets limit these curves to incoming water at 70°F or colder. Rinnai notes that maximum flow varies with set temperature, temperature rise and altitude. A qualified installer must confirm the applicable conditions and current document revision for the actual installation. [calculation]
| Inlet at 120°F outlet | Temperature rise | RX160iN approximate output | RXP160iN approximate output | RX130iN approximate output |
|---|---|---|---|---|
| 70°F | 50°F [calculation] | About 6.0 GPM [calculation] | About 6.0 GPM [calculation] | About 5.0 GPM [calculation] |
| 50°F | 70°F [calculation] | About 4.5 GPM [calculation] | About 4.5 GPM [calculation] | About 3.5 GPM [calculation] |
| 40°F | 80°F [calculation] | About 4.0 GPM [calculation] | About 4.0 GPM [calculation] | About 3.0 GPM [calculation] |
Sources: RX specifications and curves, RXP specifications and curves, installation requirements. Sizing examples use the stated assumptions.
Sources: Rinnai RX specification 100000883 and RXP specification 100000884, water-flow curves on page 2. Read the RX160i, RX130i and RXP160i lines respectively. Approximate readings are rounded to about 0.5 GPM, not guaranteed installed performance. [calculation]
| What you know | What it tells you | What it does not tell you |
|---|---|---|
| 160,000 / 160,000 / 130,000 BTU/h | The respective RX160 / RXP160 / RX130 maximum burner inputs | The GPM available at every rise |
| 0.97 / 0.97 / 0.97 UEF | The respective published efficiency metrics | How quickly a distant shower receives hot water |
| 9.0 / 9.0 / 7.1 maximum GPM | The respective maker-sheet maximum flows | An all-weather simultaneous fixture count |
| Measured winter rise plus the exact curve | Whether demand fits that model | Whether the house’s gas and vent systems are adequate |
Sources: RX specifications and curves, RXP specifications and curves, installation requirements. Sizing examples use the stated assumptions.
Separate shower flow from heater flow
A shower mixes hot and cold water. Count the hot portion when comparing demand with the heater curve; count any other simultaneous hot-water use separately.
For this example only, assume two showers each use 2.0 GPM of mixed water at 105°F, with a heater outlet of 120°F. These are selected inputs, not measured fixture flows or recommended control settings. Actual shower valves, pipe losses and water temperatures can change the result. [calculation]
At a 40°F inlet, the hot fraction is (105 − 40) ÷ (120 − 40), or 0.8125. Two showers total 4.0 GPM mixed, so their heater demand is 4.0 × 0.8125 = 3.25 GPM. The heater must deliver that hot flow at an 80°F rise. [calculation]
| Assumed inlet | Heater rise at 120°F outlet | Hot share of 105°F mixed water | Two 2.0 GPM showers: heater demand |
|---|---|---|---|
| 70°F | 50°F [calculation] | 35 ÷ 50 = 70% [calculation] | 2.80 GPM [calculation] |
| 50°F | 70°F [calculation] | 55 ÷ 70 ≈ 78.6% [calculation] | About 3.14 GPM [calculation] |
| 40°F | 80°F [calculation] | 65 ÷ 80 = 81.25% [calculation] | 3.25 GPM [calculation] |
Sources: RX specifications and curves, RXP specifications and curves, installation requirements. Sizing examples use the stated assumptions.
Formula: hot flow = mixed flow × (mixed temperature − inlet temperature) ÷ (heater outlet temperature − inlet temperature). Simplified steady-state mixing; excludes distribution losses. It is not a verified RX/RXP performance result.
If a separate tap takes an assumed 1.0 GPM entirely from the hot line during those cold-inlet showers, the combined heater demand becomes 4.25 GPM. That extra flow is an example input, not a typical tap rating. [calculation]
At an 80°F rise, RX160 and RXP160 each show about 4.0 GPM; RX130 shows about 3.0. The example’s 4.25 GPM combined demand exceeds all three rounded readings. None passes this combined-load example. Reduce overlapping use or ask the installer to assess a different heating capacity. [calculation]
The two showers alone need 3.25 GPM. That is below the RX160 and RXP160 rounded outputs, but above RX130’s approximately 3.0 GPM. Use actual flows and site conditions before selecting any of the three; a change in fixture overlap can change the result. [calculation]
A tub fill scheduled after the showers need not be counted as simultaneous shower demand. A bath that must fill while both showers run does. The installer needs that distinction before selecting a model or discussing a larger system.
Calculate the hot portion of shower demand
Formula: hot flow = mixed flow × (mixed temperature − inlet temperature) ÷ (outlet temperature − inlet temperature). Simplified steady-state mixing excludes pipe losses and other hot-water uses. These inputs illustrate arithmetic, not recommended control settings. Sizing reference.
Check the gas supply before the model
The RX and RXP need a fuel-supply assessment for the installed system. A fitting size on the heater is not proof that the existing branch can serve it.
| Question for the installer | Evidence to request | Why it matters |
|---|---|---|
| Can the meter and branch serve the heater with other loads? | Gas-load and pipe-sizing assessment for the actual route | Assess the selected 160,000 or 130,000 BTU/h heater alongside other connected appliances [1] |
| Which fuel will be configured? | Correct fuel selection and commissioning record | Smart-Sense fuel flexibility does not remove professional setup |
| Does inlet pressure meet the manual under operation? | Professional pressure verification | Pipe appearance alone cannot verify operating supply |
| Is the appliance correctly commissioned? | Completed maker checklist and combustion checks | A running burner by itself is not a full installation check |
Sources: RX specifications and curves, RXP specifications and curves, installation requirements. Sizing examples use the stated assumptions.
The RX specification lists a 3/4-inch gas connection. It also discusses smaller supply-line compatibility under specified conditions. Do not turn either statement into a blanket pipe-sizing instruction. Route length, fittings and other appliance loads belong in the qualified installer’s calculation. [1]
Rinnai describes natural gas and propane support through Smart-Sense. That feature is a commissioning capability, not homeowner permission to switch fuels. The installer must confirm the fuel configuration and follow the manual. Do not adjust the appliance’s internal gas valve to chase a flow or temperature complaint.
If you smell gas, leave the building. Do not light appliances, touch electrical switches or use any phone inside the building. From a neighbor’s phone, call the gas supplier and follow its instructions. If the supplier cannot be reached, call the fire department.
Rinnai recommends a carbon monoxide (CO) alarm in the hallway near bedrooms in each sleeping area. Its manual says to check batteries monthly and replace them annually. Follow local alarm requirements as well.
A gas appliance needs the specified combustion-air and exhaust route. Have a qualified professional inspect it; do not block a termination or improvise a vent repair.
Plan the vent and condensate as separate jobs
Condensing design affects the exhaust system and produces condensate that must be disposed of correctly. An RX or RXP needs both paths planned before its wall position is settled.
| Path | What the RX/RXP plan must establish | Mistake to avoid |
|---|---|---|
| Intake and exhaust | Approved materials, equivalent route length and termination clearances | Reusing an old vent because its diameter looks right |
| Condensate drain | Corrosion-resistant route and disposal complying with local requirements | Ending a drain where it can freeze or discharge improperly |
| Condensate pump, if needed | Suitable pumped route where gravity drainage is unavailable | Choosing the heater location before checking the drain elevation |
| Pressure relief discharge | Its own safe, code-compliant discharge arrangement | Joining it to the condensate line or plugging a discharge |
Sources: RX specifications and curves, RXP specifications and curves, installation requirements. Sizing examples use the stated assumptions.
The Rinnai manual specifically separates condensate drainage from pressure relief discharge. They solve different problems. Ask the installer to identify both on the proposed layout. A wall drawing with only intake and exhaust pipes leaves out part of the installation.
Condensate treatment is also a site question. Local disposal rules determine what the installation needs. Do not assume every drain destination accepts untreated condensate. Have the installer document the compliant disposal route and service requirements; neither the RX nor RXP’s efficiency rating settles that question.
Rinnai’s outdoor configuration differs from its indoor vent arrangement. This does not mean every indoor vent accessory is removed and the heater can be placed anywhere. Location clearances, electrical protection and exposed-water protection remain part of the outdoor configuration. Confirm those points before choosing a wall.
Decide whether you need recirculation
The RXP addresses water that cools in the distribution pipes between uses. It does not remove the need to size the burner for the fixtures that run together.
| Household situation | Useful question | Direction |
|---|---|---|
| Long wait at a distant bathroom | Is there a dedicated return or approved crossover plan? | Consider RXP after the route and controls are specified |
| Short pipe run with an acceptable wait | What problem would a pump solve here? | RX may fit without an internal pump |
| Hot water cools when other fixtures run | Does measured demand exceed available flow at winter rise? | Check capacity before treating this as a pump problem |
| Daily routine varies | Which control method suits actual occupancy? | Have the installer explain Smart-Circ and compatible control options |
Sources: RX specifications and curves, RXP specifications and curves, installation requirements. Sizing examples use the stated assumptions.
A dedicated return gives circulated water a separate path back. A crossover arrangement uses an approved connection between the hot and cold sides. The RX/RXP manual gives different setup requirements for those configurations. Ask which layout is planned and how it affects cold-water behavior at the crossover fixture.
Smart-Circ learns usage rather than promising immediate hot water at every faucet at all times. A branch beyond the circulating loop can still hold cooled water. Have the installer mark which fixtures the loop serves so the expected benefit is tied to the pipe layout rather than to a feature name.
Wi-Fi capable and pump included are different claims. The RXP has the internal pump; remote-control capability may involve separate compatible hardware. The maker’s specification separates standard equipment from optional controls.
Rinnai’s RXP sheet lists the standard package contents. The Amazon listing does not itemize the carton, so loose-part inclusion in that offer is unverified; a photo does not resolve it.
Protect outdoor pipes through freezing weather
Rinnai’s freeze protection depends on electrical power. The manual also warns that the heater’s protection does not protect all external piping and valves.
| Exposure | What to plan | Who confirms it |
|---|---|---|
| Heater installed outdoors | Approved outdoor configuration, allowed location and maker freeze requirements | Qualified installer |
| Exposed supply and service valves | Protection specifically for the external plumbing | Installer using locally suitable methods |
| Condensate route outside | Protection and routing that prevent a frozen discharge path | Installer under maker and local requirements |
| Cold-weather power loss | Written maker-based draining or protection plan | Installer before the first freezing outage |
Sources: RX specifications and curves, RXP specifications and curves, installation requirements. Sizing examples use the stated assumptions.
A gas burner does not make the RX or RXP independent of electricity. The specified power supply operates the appliance and supports its protective functions. If outage resilience is part of the reason for replacing a tank, discuss the actual electrical requirement before assuming gas tankless will keep operating.
Ask for a winter handover plan before the first cold spell, including who handles shutdown and draining when needed. Rinnai’s maintenance precautions require electrical disconnection, gas shutoff and water isolation. Do not open a hot, pressurized heater to improvise a freeze drain. Repairs and maintenance, including draining, belong to a trained and qualified professional under Rinnai’s instructions.
If the heater or exposed piping has frozen, Rinnai says not to operate it. The manual calls for closing gas and water valves and turning off power, followed by checks after thawing. Arrange professional inspection rather than repeatedly trying to run a frozen appliance or applying an open flame.
Rheem and Navien specifications compared
These are neutral comparisons of manufacturer specifications. Only the RX and RXP are purchase picks here.
| Comparison subject | Manufacturer specification | Model distinction |
|---|---|---|
| Rheem RTGH-84DVLN-3 | 157,000 BTU/h; 0.93 UEF; 4.6 GPM at 67°F rise in the cited RTGH sheet [6] | Natural-gas -3 model; separate from the propane -3 and older -2 [6] |
| Rheem RTG-95DVLN-3 | Non-condensing model in the RTG sheet | RTG non-condensing series differs from RTGH condensing series |
| Navien NPE-240A2 | ComfortFlow combines a buffer tank and recirculation pump | Condensing heater with integrated recirculation |
Sources: Rheem model sheets and Navien specifications.
Rheem’s 4.6 GPM at a stated 67°F rise is more useful for a particular load than an unexplained maximum-flow claim. It still cannot be compared fairly with an RX number taken at an unspecified rise. Put both units at the same conditions before deciding which provides enough winter water. [6]
Navien describes the NPE-240A2’s ComfortFlow system as a combination of buffer tank and recirculation pump. The RX160iN has no built-in pump and the RXP160iN includes one. Those are manufacturer-described configuration differences; this comparison does not establish a measured delivery-time ranking.
Keep the broader two-brand question separate from the RX-versus-RXP choice. My Navien versus Rinnai comparison covers that decision. The three purchase options here differ in burner input as well as pump configuration. Each still needs its own winter-demand and installation assessment.
Where listings and maker documents disagree
Use the exact model’s maker documents for specifications, and keep unresolved differences visible. Do not silently combine a favorable number from one revision with another model’s accessories.
| Item | Listing or webpage | Maker document | How to use the evidence |
|---|---|---|---|
| RX199iN maximum flow (neutral comparison) | Earlier Amazon title and Rinnai webpage: 11.1 GPM [calculation] | RX sheet: 11.0 GPM; 199,000 BTU/h; 0.98 UEF; no internal pump [1] | Larger-burner specification reference only |
| RXP199iN maximum flow (neutral comparison) | Earlier Amazon title and Rinnai webpage: 11.1 GPM [calculation] | RXP sheet: 11.0 GPM; 199,000 BTU/h; 0.98 UEF; internal pump [2] | Larger-burner specification reference only |
| RX pump capability | Recirculation capability can sound like included hardware | RX sheet lists an optional internal-pump conversion; RXP sheet describes its integrated pump | Base RX160 and RX130 have no internal pump |
| RXP160 package contents | Amazon listing does not itemize the carton | RXP specification 100000884 lists a thermal bypass valve and mounting hardware as included [calculation] | Maker package description only; exact seller carton contents unverified |
Sources: RX specifications and curves, RXP specifications and curves, installation requirements. Sizing examples use the stated assumptions.
Plan for water quality and service access
The RX/RXP manual requires annual inspection by a trained, qualified professional. Water conditions also affect cleaning needs, so maintenance belongs in the buying decision.
| Before purchase | What to record | Reason |
|---|---|---|
| Check supply-water quality | Hardness and other results against maker limits | A flushing appointment does not by itself correct unsuitable water |
| Leave access for service | Clearances and reachable isolation points | The heater needs inspection and maintenance after mounting |
| Agree on cleaning requirements | Maker procedure and interval suited to conditions | Do not borrow another brand’s flushing schedule |
| Keep purchase and install records | Exact model, serial, receipt and commissioning information | Warranty terms depend on the applicable coverage and installation conditions |
Sources: RX specifications and curves, RXP specifications and curves, installation requirements. Sizing examples use the stated assumptions.
Rinnai’s water-quality table lists total hardness up to 200 mg/L and pH 6.5 to 8.5. Those are limits in the manual, not a promise that every supply within them needs identical treatment or cleaning. Compare the full water-quality table with actual results and have the installer explain any treatment recommendation. [1] [3]
Service access needs usable space, not just permission to mount the cabinet between obstacles. Ask whether the service valves and drain points remain reachable after shelving or a pipe cover is installed. A pump-equipped RXP still needs routine appliance maintenance; recirculation is not a cleaning function.
Rinnai requires repairs and maintenance by a trained and qualified professional. Before service, that professional must let hot parts and water cool, disconnect electrical power, shut off gas, isolate the water and relieve pressure under the maker’s procedure. Gloves and safety glasses protect against hot water and injury. Do not open a hot, pressurized heater.
Warranty coverage is not a prediction of appliance life. Check the current warranty for the exact model, application and installation, including any registration or operating-hour conditions. Keep the dated receipt. Avoid comparing a headline heat-exchanger term with another maker’s entire-appliance coverage as though those were the same promise.
How to choose for your house
Bring a demand worksheet and an installation plan to the same decision. A heater that meets only one of those requirements is not ready to select.
Describe the simultaneous demand
List the fixtures that must run together and their actual flows. Separate mixed shower flow from hot-only uses, then establish the coldest expected inlet temperature.
Ask for the exact curve point
Have the installer match the selected RX160iN, RXP160iN or RX130iN output to that temperature rise. Do not accept a maximum GPM label as the whole sizing calculation.
Have the installer check fuel and venting
Rinnai requires trained, qualified installation and commissioning. The assessment needs gas sizing and an approved combustion-air/exhaust route before any gas work begins.
Choose the pump around the pipe layout
Use RX for a suitable installation without an internal-pump requirement. Use RXP when a dedicated-return or approved crossover arrangement and control method are specified.
Confirm drain, power and service needs
Document the condensate route, separate relief discharge, grounded electrical supply and annual-service access. Include an outdoor freeze and outage plan when applicable.
Match the order to the approved model
Read RX versus RXP and every suffix. Confirm heater versus accessory, current New availability and included contents before purchasing the exact linked item.
If the gas, vent or winter-demand assessment rules out all three picks, pause the heater purchase. That is a useful result of the planning work. Changing fixture overlap or considering a different system belongs with the installer’s sizing discussion, not with an unsupported promise that any gas tankless heater will cover the house.
Keep equipment selection separate from the installation estimate. Ask which vent parts, valves and drain work the installation includes, along with any electrical or permit requirements. My tankless installation cost guide explains the broader scope; no product-price assumptions are needed to identify those tasks.
Questions about gas tankless water heaters
Common questions about whole-house selection, winter flow and the RX/RXP difference.
What is the best gas tankless water heater for a whole house?
RX160iN is my starting pick when its winter curve fits; RXP160iN suits planned recirculation at the same maximum input. RX130iN serves smaller checked demand. None is a universal house-size recommendation. Confirm output at winter temperature rise and have a qualified installer approve the gas supply, vent route and drain.
How many showers can an 11.1 GPM heater run?
The maximum-flow headline cannot establish that. Use actual simultaneous hot-water demand at the required temperature rise. Two assumed 2.0 GPM showers at 105°F need 3.25 GPM of 120°F hot water with a 40°F inlet, before other use or losses. At that 80°F rise, the rounded readings are RX160 4.0 GPM, RXP160 4.0 and RX130 3.0; confirm installed conditions separately. [calculation]
What is the difference between Rinnai RX and RXP?
The base RX160iN has no internal recirculation pump; RXP160iN includes one. Both list 160,000 BTU/h maximum input, 0.97 UEF and 9.0 GPM maximum flow in their respective Rinnai sheets. The pump changes the distribution arrangement, not the listed burner capacity. [1]
Will recirculation give instant hot water at every tap?
No general promise follows from the RXP pump. Delivery depends on the return layout, controls and pipe branches serving each fixture. The manual describes dedicated and crossover modes. Ask the installer which taps the planned loop serves and what wait can remain outside that loop.
Can a gas tankless water heater work without electricity?
The RX and RXP require electrical power; the specified appliance supply is 120 VAC, 60 Hz. Rinnai also ties freeze protection to power. If outages matter, have a qualified professional establish an approved protection plan rather than assuming the gas connection makes either heater independent of electricity. [calculation] [1]
Can the RX160iN, RXP160iN or RX130iN go outdoors?
Rinnai allows these heaters outdoors in its approved outdoor configuration. The installer must also satisfy placement clearances and protect exposed piping and the condensate route. The cabinet’s freeze protection does not cover all external valves and pipes, and a freezing power outage needs a separate plan.
Is Rheem RTG-84XLN-1 the same as RTG-84XLN-3?
Does a condensing heater need a drain?
The RX/RXP manual requires compliant condensate disposal. It specifies corrosion-resistant drainage and separates condensate from pressure relief discharge. Have the installer establish the drain route, any required neutralization and freeze protection. An outdoor cap does not remove condensate from the installation plan.
Can I replace a tank heater with tankless myself?
Rinnai requires trained, qualified installation and service. A replacement needs fuel sizing, combustion-air and exhaust checks, plus compliant water, drain and electrical connections. Have a qualified professional do the gas and vent work. Rinnai also reserves repairs and maintenance for a trained and qualified professional, with cooling, electrical/gas/water isolation and pressure precautions under its procedure.
How often does a Rinnai gas tankless heater need maintenance?
The RX/RXP manual requires annual inspection by a trained, qualified professional. Cleaning needs depend on water quality and operating conditions. Follow this model’s instructions rather than transferring a Rheem interval or assuming a pump removes scale. Keep the service record with the model and serial information.
Are the picks covered by the 2025 Rinnai recall?
The cited June 2025 CPSC notice concerns specified i-Series Plus boilers rather than RX or RXP tankless water heaters. The November 15, 2026 search for these picks found no applicable active recall. Check the exact model and serial against current notices before installation; a brand search alone is not unlimited clearance.
How I choose
Why I recommend these models
I’m Isaac Daniels, and I’m responsible for these recommendations. The RX/RXP distinctions come from Rinnai’s specification, installation manual and model pages. I separate model-specific source facts from conditional buying judgments and show the winter-capacity differences.
How I chose
I compared three exact heater models, their pump arrangements and installation requirements. I re-read the Amazon listings on Nov 15, 2026, 12:47 PM EST for genuine model identity, New condition and stock: RX160, RXP160 and RX130 are all branded Rinnai, new and in stock on Amazon.
I compare the actual model specifications below rather than assigning a score. The water-mixing example is arithmetic with stated assumptions, not a measured heater test. CPSC recall evidence was checked for model relevance. Product photos come from Amazon from the Amazon listings.
| Selection check | How it changes the recommendation |
|---|---|
| Winter heating capacity | Require the matching maker curve; no fabricated flow result or bathroom count |
| Pump and return path | RX without a built-in pump; RXP for designed internal-pump recirculation |
| Installation fit | Gas, approved vent, condensate, electricity and freeze requirements must all be addressed |
| Offer identity | Recommend only exact genuine Rinnai models, new and in stock in the Amazon listing check of Nov 15, 2026, 12:47 PM EST |
Sources: RX specifications and curves, RXP specifications and curves, installation requirements. Sizing examples use the stated assumptions.
Sources
- Rinnai SENSEI RX residential specification 100000883, pages 1 to 2; RX160 15,000 to 160,000 BTU/h, 0.97 UEF, 9.0 GPM maximum, model-specific inputs, venting and page 2 water-flow curves. Read source 1
- Rinnai SENSEI RXP residential specification 100000884, pages 1 to 3; RXP160 160,000 BTU/h, 0.97 UEF, 9.0 GPM maximum, integrated pump, maker package contents, venting and page 2 water-flow curve. Read source 2
- Rinnai SENSEI RX/RXP installation and operation manual, 100000839(03), March 3, 2025: safety, installation, condensate, pump configuration, annual inspection, water quality and freeze protection. Read source 3
- PNNL Building America Solution Center, DHW Instantaneous Sizing: temperature rise and the distinction between mixed-fixture flow and hot-water demand. basc.pnnl.gov/redcalc/tool/dhw-instantaneous-sizing. Read source 4
- DOE/IBACOS, Measure Guideline: Transitioning to a Tankless Water Heater, September 2012, sections 2.1 to 2.4 and 4.1: demand, winter sizing and distribution delay. Read source 5
- Rheem RTGH series condensing specification TK-RTGH SERIES Rev.2, October 2024; RTG/RTG-R non-condensing specification RH-RTG-RTGR-SS Rev.1, February 2026: exact-model comparison facts. ; Read source 6
- Navien NPE-240A2 official product specifications and ComfortFlow description. navieninc.com/products/npe-240a2. Read source 7
- CPSC recall records and model checks dated November 15, 2026, re-checked Nov 15, 2026, 12:47 PM EST (no RX or RXP heater recall), including June 5, 2025 Rinnai i-Series Plus boiler notice. cpsc.gov. Read source 8
- Amazon listings, Nov 15, 2026, 12:47 PM EST: RX160, RXP160 and RX130; brand Rinnai, new, in stock, sold through Amazon. Earlier read October 20, 2026. Availability can change.
- Sizing arithmetic uses the formula and assumptions shown in the demand example and calculator. Model flow readings come from the plotted curves on page 2 of the RX and RXP sheets; they are rounded estimates.