Best thermostatic mixing valve

I pick the Cash Acme HG110-D thermostatic mixing valve for a heater that also feeds a tub. For sweat unions, I pick the HG110-HX; for PEX, the Zurn ZW1017XL.

As an Amazon Associate I earn from qualifying purchases.

Cash Acme HG110-D 25523 threaded thermostatic mixing valve
Cash Acme HG110-D 25523. Product photo from the Amazon listing.

The short answer

Top pick: Cash Acme HG110-D. It’s listed to ASSE 1017 and 1070, so one valve at the heater can also cover a tub. Running PEX? Get the Zurn ZW1017XL. [1] [5]

Cash Acme HG110-D 3/4-inch thermostatic mixing valve with female threaded unions and a blue adjusting cap
Top pick: Cash Acme HG110-D$109.00 at AmazonPrice as of Nov 22, 2026, 9:30 AM EST
Check it on Amazon
On this page
  1. My picks
  2. Cash Acme HG110-D
  3. Cash Acme HG110-D
  4. Setting checker
  5. Cash Acme HG110-HX
  6. Cash Acme HG110-HX
  7. What a TMV does
  8. ASSE 1017 vs 1070
  9. Zurn ZW1017XL
  10. Zurn ZW1017XL
  11. Compare all three
  12. Tank temperature
  13. Where it goes and how
  14. Tankless heaters
  15. Under-sink valves
  16. Problems and fixes
  17. How I compare specs
  18. Checked and left out
  19. FAQ
  20. How I pick

My picks

Cash Acme HG110-HX 3/4-inch thermostatic mixing valve with chrome union nuts and sweat tailpieces
Best for sweat copper with unions on all three ports

Cash Acme HG110-HX

$150.30 at Amazon
Check it on Amazon
Price as of Nov 22, 2026, 9:30 AM EST · low stock then
Details ↓

Cash Acme HG110-D: one valve for the heater and the tub

Best for a heater that also feeds a tub

Cash Acme HG110-D

3/4 in. thermostatic mixing valve (Heatguard 110-D LF) [1] [12]

25523, 3/4 in. female thread (FNPT)
25523, 3/4 in. female thread (FNPT)
$109.00 at Amazon
Check it on Amazon
Price as of Nov 22, 2026, 9:30 AM EST
24549, 3/4 in. direct SharkBite
24549, 3/4 in. direct SharkBite
$110.53 at Amazon
Check it on Amazon
Price as of Nov 22, 2026, 9:30 AM EST

Pros

  • Listed to ASSE 1017, 1069 and 1070, the only pick with a 1070 listing
  • Check valves built into both inlets
  • Rated to 230 psi, the highest here
  • Five-year RWC warranty on Cash Acme mixing valves
  • Factory set and locked at 120°F

Cons

  • Needs the tank 27°F hotter than the setting, so 147°F for a 120°F outlet
  • Top of the range is 130°F
  • Amazon bullets on the threaded version are copied from the push-fit one
25523 / 245493/4 in.85–130°F outlet230 psi14 gpm at 50 psi drop [1] [12]

Buy it if

You want one valve at the heater that delivers 120°F to the whole house, including a tub, and you’ll set the tank hot enough for it. [1]

Skip it if

You need the outlet above 130°F for a hydronic loop or a deep sink. The HG110-HX goes to 176°F. [1] [3]

The Cash Acme HG110-D is my top pick because it’s the only valve here that can do two jobs. Cash Acme lists it to ASSE 1017, the standard for a valve at the heater, and to ASSE 1070, the standard for a valve that limits water at a fixture. It’s also listed to ASSE 1069 for gang showers. [1]

That matters for tubs. The IPC says a bathtub must have, or be supplied by, an ASSE 1070 device set to 120°F or less. A valve listed only to 1017 doesn’t meet that alone. With the HG110-D at the heater, one valve can supply the tub. Your inspector has the final word, so ask before you skip a valve at the tub. [8] [1]

Cash Acme ships it set and locked at 120°F, and you can adjust it from 85 to 130°F. The lock stops anyone from turning it above 120°F. Cash Acme says the stop may come out only for jobs outside ASSE 1070’s scope. Leave it in if the valve feeds a tub. [2] [1]

Here’s the catch most listings skip. Cash Acme’s instructions say the hot water feeding the valve should be at least 27°F hotter than the setting. For a 120°F outlet, that’s a 147°F tank. Set the tank at 140°F and the outlet may wander. The setting checker below does that math. [2] [14]

Both inlets have check valves built in, so hot water can’t push back into the cold line. Cash Acme puts stainless strainer screens in the inlets too. The body is lead-free DZR brass, rated to 230 psi, with a maximum flow of 14 gpm at a 50 psi pressure drop. [1] [2]

There are two genuine 3/4 in. versions on Amazon, both sold by Amazon. The 25523 has female threads, and the 24549 has SharkBite push-fit ends that take copper, PEX and CPVC. The 25523’s bullets say no tools or soldering, which is copied from the push-fit version. Threads still need sealant, used lightly; Cash Acme warns that too much can make the valve fail. [12] [2]

Will your tank setting work with each valve?

Enter your tank setting, your cold water temperature and the outlet you want. The checker tests each pick against its maker’s published limits.

Cash Acme HG110-D: works. The tank is 30°F above the setting, and it needs 27°F. Its ASSE 1070 listing can cover the tub too, so ask your inspector. [14] [2] [1]

Cash Acme HG110-HX: in range. Cash Acme’s HG110-HX instructions also require the hot supply to be at least 27°F above the outlet setting, so 147°F for a 120°F outlet. The tub still needs its own ASSE 1070 device. [4] [14] [8]

Zurn ZW1017XL: works. The tank is 30°F above the setting, and it needs 20°F. The tub still needs its own ASSE 1070 device. [5] [14] [8]

Each gallon of 150°F tank water makes about 1.46 gallons of 120°F water once 32% cold is mixed in. [14]

Read the tank setting off the thermostat, or measure the hot water right at the heater’s outlet. Cold water runs colder in winter, so check it in January too. Limits are each maker’s published figures; the code note follows the IPC.

The checker compares published ranges. It cannot replace a temperature measurement or an in-person plumbing check.

The approach is the gap between the hot water feeding the valve and the setting. A thermostatic valve needs that headroom to hold its setting when someone opens a tap. Zurn asks for 20°F. Cash Acme asks for 27°F. [5] [2]

The last line is simple mixing math, ignoring heat lost in the pipes. It shows why a hot tank plus a mixing valve gives more usable hot water: part of every gallon is cold water from the main.

Waterheaterset 140°F+Cold inHot outHot to dishwasher (optional)CHTMVMixed 120°F to houseCheck valves inside H and CMount the valve below the heater’s hot outlet line (Zurn). Not to scale. Waterheaterset 140°F+Cold inHot outCHTMVMixed 120°F to houseCheck valves insidethe H and C portsMount the valve below theheater’s hot outlet line (Zurn).Not to scale.
How a heat-source valve is piped: cold splits to the heater and the valve’s C port, hot goes to the H port, and the mixed outlet feeds the house. Drawn from Cash Acme’s and Zurn’s installation sheets. Not to scale.

Cash Acme HG110-HX: sweat unions and a wide range

Best for sweat copper with unions on all three ports

Cash Acme HG110-HX

3/4 in. thermostatic mixing valve, sweat connections (24514) [3]

24514, 3/4 in. sweat with unions
24514, 3/4 in. sweat with unions
$150.30 at Amazon
Check it on Amazon
Price as of Nov 22, 2026, 9:30 AM EST · low stock then

Pros

  • Union connections on all three ports, so the body comes out without cutting pipe
  • Outlet range reaches 176°F
  • Check valves at both inlets as standard
  • Rated to 230 psi and up to 20 gpm
  • Five-year RWC warranty

Cons

  • Listed to ASSE 1017 only, so a tub still needs a 1070 device
  • Amazon bullets give the wrong range (85–130°F) and say no soldering
  • Needs 27°F of approach under the installation instructions
245143/4 in. sweat85–176°F outlet230 psi1–20 gpm [3]

Buy it if

You’re sweating copper at the heater and want unions on every port, or you need tempered water hotter than 130°F somewhere in the system. [3] [1]

Skip it if

You want one valve that also covers a tub. The HG110-D carries the ASSE 1070 listing. [1]

The HG110-HX is the Cash Acme valve I’d sweat in at a heater when I want to be able to service it later. Cash Acme builds it with union connections on all three ports. You sweat the tailpieces, then the body comes out by loosening three nuts, without cutting any pipe.

Cash Acme’s sheet calls it a heat-source valve. It’s meant to go in with the water heating source and send tempered water to the system, and it’s listed to ASSE 1017 and CSA B125.3. It isn’t listed to ASSE 1070, so it doesn’t cover a bathtub on its own. Pair it with a 1070 valve at the tub, or pick the HG110-D. [3] [1]

The range is the other difference. The HG110-HX adjusts from 85°F up to 176°F, where the HG110-D stops at 130°F. Cash Acme says that makes it a fit for heating systems or any job that needs reduced-temperature hot water. For a house, you’d still set it near 120°F. [3] [1]

It comes from the factory at 115 to 120°F. Cash Acme builds the adjuster tool into the knob, which keeps casual hands off the setting. Check valves at both inlets come standard. It’s rated to 230 psi, with flow from 1 to 20 gpm. [3] [4]

Watch the Amazon listing. Its bullets are copied from Cash Acme’s push-fit valves. They give an 85 to 130°F range and say the valve needs no tools, crimping, glue or soldering. Cash Acme’s own sheet says 85 to 176°F, and this one has sweat connections. I use the maker’s range and the actual sweat connection when choosing it. [12] [3]

Cash Acme warns not to heat the valve during installation. Sweat the tailpieces off the body, let them cool, then assemble. Cash Acme’s HG110-HX instructions require the hot supply to be at least 27°F above the setting. The fresh Amazon offer is new and sold by Amazon.com; stock can change. [4] [12]

What a thermostatic mixing valve does

It blends hot and cold water to one set temperature, and keeps it there when pressures and temperatures change.

Inside the valve, a thermostatic element sits in the mixed water. As the water warms, the element grows and slides a piston that lets in less hot and more cold. As it cools, it does the reverse. Caleffi’s sheet describes the same idea: the element keeps setting the right share of hot and cold.

The purpose is two things at once. The tank can store water hot enough to keep Legionella down, and the taps get water cool enough not to scald. Caleffi says hot water should be stored at 140°F or more for that reason, and advises limiting mixed water to 120°F. [7]

Valve typeWhat it reacts toWhere it goesStandard
Thermostatic mixing valve at the heaterMixed water temperatureOn the water heater’s outletASSE 1017 [1] [5]
Temperature-limiting valve at a fixtureMixed water temperatureUnder a sink or before a tubASSE 1070 [1] [11]
Pressure-balancing shower valveHot and cold pressureInside the shower wallASSE 1016 [8]
Plain mixing valve (no thermostat)Nothing; it’s a fixed blendHydronic and older systemsNot a scald device

Mixing valve vs thermostatic mixing valve: every TMV is a mixing valve, but not every mixing valve is thermostatic. A thermostatic one corrects itself when supply temperatures or pressures change. Shower valves are a separate product, covered in pressure-balancing vs thermostatic shower valves.

ASSE 1017 vs 1070: which listing your job needs

The listing decides where a valve may legally go. It’s the first thing an inspector reads on the box.

The listing and certification descriptions below are the manufacturers’ published statements. I check the current instructions and local requirements before treating a heater valve as the protection for a fixture.

StandardWhat it coversHG110-DHG110-HXZurn ZW1017XL
ASSE 1017 [1] [3] [5]Valve at the hot water source, feeding the systemListed [1]Listed [3]Listed [5]
ASSE 1070 [1]Controls water at a fixture, like a tub or lavatoryListed [1]Not listed [3]Not listed [5]
ASSE 1069 [1]Gang showers where the bather can’t adjustListed [1]Not listed [3]Not listed [5]
CSA B125.3 [1] [3] [5]Canadian plumbing fittings standardListed [1]Listed [3]Listed [5]
NSF/ANSI/CAN 372 [1] [3] [5]Low lead in drinking water partsListed [1]Listed [3]Meets it [5]

Listings from Cash Acme’s HG110-D sheet (rev. Feb 2026), its HG110-HX sheet, and Zurn’s ZW1017XL sheet (rev. Jan 2026), read Oct 22, 2026.

Fixture (IPC 2024, Chapter 4)LimitDevice the code names
Bathtub and whirlpool tub120°F [8]ASSE 1070 device, field adjusted [8]
Shower and tub-shower valve120°F [8]Valve with a max-temperature limit
Bidet110°F [8]ASSE 1070 device [8]
Public hand-washing sink (tempered water)TemperedASSE 1070 device [8]
Head shampoo sink, pedicure footbath120°F [8]ASSE 1070 device [8]

These are common IPC fixture limits, not every permitted design. The 2024 IPC also permits qualifying ASSE 1082 or 1084 water heaters for specified applications. Combination tub/shower valves follow their own section. I verify the complete adopted code and installation before choosing the protection. [8] [9]

Zurn spells out the trap on its own sheet. It says the ZW1017XL should never go at the point of use where someone could change its setting, and that a point-of-use device must be the ASSE 1070 kind. A 1017 valve at the heater doesn’t replace the tub’s 1070 device. [5]

Your town adopts its own code, often the IPC or UPC with changes. Check yours before you plan on one valve doing two jobs.

Zurn ZW1017XL: PEX ends and the lowest approach

Best for PEX at the water heater

Zurn ZW1017XL

Zurn Wilkins 34-ZW1017XL2PEX1C Aqua-Gard thermostatic mixing valve, 3/4 in. [12] [5]

34-ZW1017XL2PEX1C, two PEX + one sweat tailpiece
34-ZW1017XL2PEX1C, two PEX + one sweat tailpiece
$113.74 at Amazon
Check it on Amazon
Price as of Nov 22, 2026, 9:30 AM EST

Pros

  • Needs only 20°F of approach, so a 140°F tank holds 120°F
  • Two PEX barb tailpieces and one copper sweat tailpiece with union nuts
  • Published accuracy of ±4°F
  • Highest flow published here: 18 gpm at 45 psi drop
  • Inlet strainers and check valves included

Cons

  • Listed to ASSE 1017 only, and Zurn says never at the point of use
  • Rated to 145 psi, the lowest here
  • Zurn’s warranty is 12 months, and you ship the valve back
34-ZW1017XL2PEX1C3/4 in.95–131°F outlet145 psi18 gpm at 45 psi drop [5] [12]

Buy it if

Your heater is piped in PEX, your tank sits at 140°F, and you want a valve that holds 120°F at that setting. [5] [14]

Skip it if

Your house pressure runs high without a reducing valve, or you want one valve to cover a tub. Pick the HG110-D.

The Zurn ZW1017XL is the pick for a PEX job at the heater. This kit, 34-ZW1017XL2PEX1C, comes with two PEX barb tailpieces and one copper sweat tailpiece, plus union nuts. Amazon’s listing says inlet strainers and check valves are included, and it’s sold by Amazon.

It has the smallest approach of the three. Zurn asks for 20°F between the hot supply and the setting, where Cash Acme asks for 27°F. That means a tank at 140°F can hold a steady 120°F outlet. With the HG110-D, you’d want 147°F. If you don’t want to run the tank hotter, that’s the reason to buy the Zurn. [5] [2] [14] [1]

Zurn publishes the tightest accuracy of the picks, ±4°F, and the highest flow, 18 gpm at a 45 psi pressure drop. The outlet adjusts from 95 to 131°F. The hot supply can run from 120 up to 195°F. The body is low-lead cast bronze, and the checks and guide tube are NORYL plastic. [5]

Zurn is blunt about where it belongs. The ZW1017XL is a point-of-source valve. Zurn says it should never be installed at the point of use where someone could change it, and that it must be used with an ASSE 1070 device at the fixture. Plan on a separate valve at the tub. [5]

Two limits matter to my choice. It’s rated to 145 psi of inlet pressure, where the Cash Acme valves take 230 psi, and Zurn caps the pressure difference between the hot and cold inlets at 15 psi. Zurn’s warranty runs 12 months from purchase, and you return the valve freight prepaid for repair or replacement. [5] [1] [6]

Zurn’s sheet adds two setup tips I follow. Put a shutoff and a thermometer on the tempered line. Mount the valve below the heater’s hot outlet line, so a clogged screen can’t send full-hot water through. To set it, pop off the green cap and turn the flats with a wrench; clockwise lowers the temperature.

All three valves side by side

PickPhotoBest forListingsOutlet rangeApproachMax pressureShort pros / consBuy
Cash Acme HG110-DCash Acme HG110-DHeater that feeds a tub1017, 1069, 1070 [1]85–130°F [1]27°F [2]230 psi [1]Covers a tub / Needs 147°F tank [14]Check it on Amazon
Cash Acme HG110-HXCash Acme HG110-HXSweat copper, unions1017 [3]85–176°F [3]27°F (installation instructions) [4]230 psi [3]Three unions / Listing errorsCheck it on Amazon
Zurn ZW1017XLZurn ZW1017XLPEX at the heater1017 [5]95–131°F [5]20°F [5]145 psi [5]Holds 120°F at 140°F / 12-month warranty [5] [14] [6]Check it on Amazon

How hot to set the tank with a mixing valve

The valve lets you store water hotter than you’d ever want at a tap. The maker’s approach tells you how much hotter.

Cash Acme HG110-D147°FCaleffi 521 (left out)147°FZurn ZW1017XL140°FCash Acme HG110-D147°FCaleffi 521 (left out)147°FZurn ZW1017XL140°F
The outlet setting plus each maker’s published approach: 27°F for Cash Acme, 20°F for Zurn. Cash Acme’s HG110-HX installation instructions also require 27°F of approach.

Why go hotter at all? Caleffi’s sheet gives the two numbers that drive it. Stored water should be at least 140°F to keep Legionella down. Mixed water above 120°F burns fast: partial burns in about 30 seconds at 130°F, and about 5 seconds at 140°F. Caleffi says the time can drop by half or more for children and older adults. [7]

So the tank runs hot and the valve brings the tap water down. Cash Acme ships its valves set with a 150°F hot supply. With a 147°F to 150°F tank, the HG110-D has its full 27°F of headroom at a 120°F setting. [2] [14] [1]

Hotter storage costs a little more in standby heat, but you get more 120°F water per tank, as the setting checker shows. A 50-gallon tank at 150°F, mixed with 55°F water, stretches to about 73 gallons at 120°F before pipe losses. [14]

Set the tank at 140°F or more if

You’re adding a mixing valve and want Legionella control plus more hot water per tank.

Check the approach if

Your tank sits at 140°F and you pick a Cash Acme valve. It wants 147°F for a steady 120°F. [2] [14]

Don’t raise the tank without a valve

A tank at 140°F with no mixing valve sends scald-temperature water to every tap. [7]

Where a mixing valve goes and how it’s piped

A heat-source valve sits on the water heater’s hot outlet, with a cold branch run to it.

When to call a plumber: I would have a qualified plumber size, install and commission this safety valve, especially with hotter storage, recirculation or a tub. Do not raise a heater setting until the mixing and fixture protection have been verified with a thermometer.

  1. 1
    Shut off the heater and the water

    Turn the heater off or to pilot, close the cold supply, and open a hot tap to drop the pressure.

  2. 2
    Flush the lines before the valve goes in

    Cash Acme calls poor flushing the most common cause of trouble. Zurn says flush both lines completely first.

  3. 3
    Run hot to H and cold to C

    Hot from the heater outlet goes to H, a cold branch goes to C, and the mixed port feeds the house.

  4. 4
    Keep heat and extra sealant off the valve

    Sweat tailpieces off the body. Cash Acme warns that heat damages the internals and too much thread sealant can make it fail.

  5. 5
    Mount it below the hot outlet line

    Zurn says this keeps a clogged screen from sending full-hot water through. Add a shutoff and thermometer on the mixed line.

  6. 6
    Set it with a thermometer at a tap

    Run the nearest fixture, read the temperature, adjust, then lock or cap the valve. Set 120°F or less where a tub is fed. [8]

Want the dishwasher to get full-hot water? Cash Acme’s diagram tees the dishwasher off the hot line before the valve. Check your dishwasher’s manual first; many heat their own water now.

On a recirculating system, the return piping changes. Caleffi’s sheet shows a bypass valve and a return valve that set how much warm return water flows back to the tank. For pumps, see hot water recirculating pumps.

Hotter storage means more expansion too. If your system has a check valve or reducing valve at the meter, it needs an expansion tank.

Do you need a mixing valve on a tankless heater?

Usually not for Legionella, because a tankless heater doesn’t store water. People still add one when the heater is set high for a hydronic coil or a commercial load. Caleffi warns that its 5231 series, the version it designs for water heaters with storage, may deliver fluctuating mixed temperatures on an instantaneous heater. [7]

Low flow is the other issue. Cash Acme lists a 0.5 gpm minimum for the HG110-D, and Zurn lists 0.5 gpm. A tankless heater has its own minimum flow to fire. Check both numbers before you put a valve in front of one. [1] [5]

Comparing heaters first? See tankless water heater brands.

Under-sink and point-of-use mixing valves

A small ASSE 1070 valve under one sink or at one tub is a different product from the heater valves above. [11]

Pick a point-of-use valve if

You only need to limit one fixture, like a lavatory in a public restroom or a single tub.

Pick a heat-source valve if

You want the whole house tempered and the tank stored hot for Legionella control.

Check the listing if

A small valve is sold for under a sink. It should say ASSE 1070 for that job. [11]

Two genuine ones on Amazon: the Cash Acme HG145, 3/8 in. compression (see it on Amazon), with built-in checks, and the Watts USG-B-M2 Under Sink Guardian (see it on Amazon), with a tamper-resistant locking nut and built-in checks. I keep them separate because they do a different job from the heater valves. [12] [11]

Watts USG-B-M2 0204141 point-of-use mixing valve
Watts USG-B-M2 0204141. Product photo from Amazon. Sold by Maintak at the November 15 check.

$121.88 [13]

Price as of Nov 15, 2026, 5:30 AM EST

Cash Acme HG145 24524 point-of-use mixing valve
Cash Acme HG145 24524. Product photo from Amazon. Sold by Amazon.com at the November 15 check.

$73.19 [13]

Price as of Nov 15, 2026, 5:30 AM EST

Mixing valve problems and what causes them

Cash Acme calls its valve a safety valve and says to check it at least once a year. [2] Zurn requires annual inspection. [6]

What you seeLikely cause (Cash Acme’s list)Fix
Can’t reach the temperature you wantSupply temperatures out of range, hot and cold reversed, blocked strainersCheck the tank setting, swap the lines, clean the screens
Temperature drifts over timeBlocked strainers or swinging supply pressuresClean the strainers; add pressure-reducing valves
Full hot or full cold at the tapValve set wrong, lines reversed, or water crossing between inletsReset it; clean or replace the check valves
No flow from the valveHot or cold supply off, or blocked strainersRestore the supply and recheck the setting
Hot water shows up in the cold lineFouled check valvesClean the checks
Valve is noisyWater moving too fast, or a valve too small for the flowLower the pressure; check the sizing

Cash Acme says to check the temperature each year at the same tap used when it was set. If it’s more than 5°F off, work down the list above. Seasonal changes in cold water temperature can move the outlet a little, so a small winter drift is normal. [2]

Hard water is the usual enemy. Scale builds on the strainers and the piston. Caleffi makes its sliding parts from an anti-scale plastic for that reason. On any valve, clean the inlet screens at the yearly check.

How I compare the specifications

I compare ASSE application, included check valves, warranty terms, pressure limits and whether the listing matches the exact connection type. I do not compare headline flow figures as if they were measured at the same pressure drop. My choice starts with the installation, then the manufacturer’s limits.

Valves I checked and left out

ValveWhat held it backWhat it does well
Honeywell AM101-US-1LFNo ASSE 1070 listing on Resideo’s sheet; 150 psi maximum pressure [10] [8]Cv 3.9, the highest flow factor in this comparison [10] [7]
Caleffi MixCal 521509ANo inlet checks (the AC version has them); Caleffi’s warranty excludes products not bought from Caleffi±3°F tolerance and a 200 psi rating [7]
Watts LFMMVOnly a few left from third-party sellers at my readCommon at supply houses
Cash Acme HG160, HG145; Zurn ZW1070XL; Watts USGPoint-of-use valves, a different jobASSE 1070 at one fixture [15] [11]

Thermostatic mixing valve questions

What is a thermostatic mixing valve?

It’s a valve that blends hot and cold water to one set temperature and holds it as supply pressures and temperatures change. At a water heater, it lets the tank store hot water while the taps get about 120°F. [1]

What is the purpose of a mixing valve on a water heater?

Two things: you can store water at 140°F or more, which Caleffi says keeps Legionella down, and the house still gets safer water near 120°F. It also stretches each tank, because cold water makes up part of every gallon. [7]

What is the difference between a mixing valve and a thermostatic mixing valve?

A plain mixing valve holds a fixed blend. A thermostatic one has an element that senses the mixed water and corrects itself, so the temperature holds when someone flushes a toilet or the tank cools.

Where is a thermostatic mixing valve located?

A heat-source valve sits on or near the water heater, on the hot outlet with a cold branch run to it. A point-of-use valve sits under a sink or before a tub. Zurn says to mount its heater valve below the hot outlet line.

What temperature should a mixing valve be set to?

120°F or less for a house, and the IPC caps tubs at 120°F and bidets at 110°F. Set it with a thermometer at a tap. Cash Acme ships its valves set and locked at 120°F. [8] [2]

Do I need a mixing valve for a tub?

The IPC says a tub must have, or be supplied by, an ASSE 1070 device set to 120°F or less. A valve listed only to ASSE 1017 at the heater doesn’t meet that alone. The Cash Acme HG110-D is listed to both. [8] [1]

How hot does the water heater need to be with a mixing valve?

At least the setting plus the maker’s approach: 27°F for Cash Acme, 20°F for Zurn. For a 120°F outlet, that’s 147°F or 140°F. The setting checker on this page works it out. [2] [5] [14]

How often should a thermostatic mixing valve be checked?

At least once a year. Cash Acme calls it a safety valve and says to recheck the temperature at the same tap used to set it. Zurn requires annual inspection, testing and cleaning.

How I pick and why you can trust it

I compared three water-heater valve families and checked six Amazon listings, including the two point-of-use alternatives. I use the Cash Acme and Zurn specification and installation sheets for connection sizes, outlet ranges, pressure limits and commissioning requirements.

Why trust me

I’m Isaac Daniels, a licensed journeyman plumber in Georgia. I choose these valves by pipe connection, manufacturer specifications and whether the installation also supplies a tub. I check the exact model and connection before choosing a valve.

How I pick

  • I compare the application and published limits before choosing a valve.
  • Listings, ranges, pressures and warranties from each maker’s sheet, checked against the Amazon listing.
  • Every pick is new, genuine and in stock, sold by Amazon at my read.
  • I compare the application and published limits before choosing a valve.
  • Code limits come from the 2024 IPC; your local code may differ.
  • Use the Amazon button for the current price and availability.

Sources

  1. Cash Acme, HG110-D specification sheet (Rev 2.0), cashacme.com. Saved text: evidence/d-spec.txt. Official source
  2. Cash Acme, HG110-D installation instructions IS291 Rev C, cashacme.com. Saved text: evidence/d-install.txt. Official source
  3. Cash Acme, HG110-HX specification sheet (Rev 2.0), cashacme.com. Saved text: evidence/hx-spec.txt. Official source
  4. Cash Acme, HG110-HX installation instructions I0469 Rev A, cashacme.com. Saved text: evidence/hx-install.txt. Official source
  5. Zurn Wilkins, ZW1017XL specification sheet (Rev K), zurn.com. Saved text: evidence/zurn-spec.txt. Official source
  6. Zurn Wilkins, ZW1017XL installation and warranty sheet ISZW1017XL (Rev F), zurn.com. Saved text: evidence/zurn-install.txt. Official source
  7. Caleffi, MixCal 521 series technical brochure 01050/23.1 NA, caleffi.com. Saved text: evidence/caleffi.txt. Official source
  8. IPC fixture temperature limits, from Ohio Administrative Code 4101:3-4-01 (Ohio Plumbing Code) and Municipal Code of Chicago 18-29-424.3 and 18-29-424.5. Saved excerpts: evidence/ipc-fixture-limits.txt. Official source
  9. Georgia Department of Community Affairs, current state minimum standard codes (International Plumbing Code, 2024 Edition, with Georgia Amendments). Saved text: evidence/georgia-dca-codes.txt. Official source
  10. Resideo (Honeywell Home), AM101-US-1LF product data. Saved text: evidence/honeywell-am101-lf.txt. Official source
  11. Watts, LFUSG-B-M2 engineering specification ES-LFUSG-B-M2. Saved text: evidence/watts-usg.txt. Official source
  12. Amazon listing features and offers for the six valves on this page, read on Amazon on November 15, 2026.
  13. Amazon prices from the price feed generated November 15, 2026, 5:30 AM EST. Saved record: evidence/prices-feed.json.
  14. Mixing math worked from the maker approach figures in sources 2, 4 and 5 and the setting checker defaults on this page. Saved record: evidence/calculations.txt.
  15. Cash Acme, HG145 specification sheet, cashacme.com. Saved text: evidence/hg145-spec.txt. Official source

Related guides