How to find your drain cleanout

I check drain cleanout locations near the drain stack, outside-wall exit and sewer route first. Here is where to look, when to leave the cap closed, and which plug fits.

As an Amazon Associate I earn from qualifying purchases. How this site earns

Updated November 15, 2026 · How I chose

Sioux Chief 878-20 white slotted cleanout plug
Sioux Chief 878-20, for a confirmed matching 2 in. fitting. Photo from the Amazon listing.

The short answer

Check near the basement drain stack, the drain’s outside-wall exit and the sewer route toward the property line.[5][6] A cap is a clue, not proof. Leave it closed during a backup; match the fitting before replacing its plug.

2, 3 or 4 in. threaded plug: match the confirmed fitting[2][3] · Find your next step

Find your next step

[2][3]

This finder cannot identify a buried pipe or replace an in-person fitting check.

Where to look for a sewer cleanout

Start with visible pipe and records. A cleanout search should not begin with a shovel or a loosened cap.

Follow the evidence Basement / utility areaVisible drain and closed capRecord the wall exit Outside wallLook for a riser or boxConfirm sanitary drainage Property line / alleyCompare with lateral recordsAsk the utility about access Sewer connectionRoute may differ from sketchNo cap visible? Arrange locating Dashed line = search sequence.It does not locate a buried pipe.Keep caps closed during a backup.
Illustrative search route, not a surveyed pipe layout. Minneapolis identifies basement and outside-wall locations; Anne Arundel County identifies property-line cleanouts. Your sewer may run toward a rear alley or a septic system instead.
Basement or accessible utility area

Look for a capped opening on or near the large drain stack and the drain route through the outside wall.[5] Compare visible pipe markings with the inspection record.

Outside the foundation

Look along the likely drain exit for a capped riser or access box. Move loose leaves aside by hand without opening or altering the fitting.

Along the sewer route

Check visible access boxes toward the street, alley or recorded lateral connection. A property-line cleanout is a local arrangement, not a feature guaranteed at every house.[6]

Nothing visible

Ask the sewer utility for lateral records and a plumber for locating help. A missing visible cap does not prove that the buried line has no access.[5][6]

The City of Minneapolis describes a sewer cleanout as a capped access pipe to the private sewer lateral.[5] Its guidance puts the search in the basement and near exterior walls, including behind shrubs.[5] That is a useful starting pattern for a home with a basement, rather than a promise about every floor plan.

In a slab house, begin outside where the building drain is likely to leave the footprint. Use an existing drawing or inspection record to narrow that area. Do not assume the pipe exits directly behind the nearest toilet; a visible bathroom wall does not show the buried route.

Anne Arundel County describes another common arrangement: a cleanout near the property line.[6] Its local cap-height requirement is specific to that county.[6] Keep a raised cap intact until you know your own utility’s rules; cutting it flush for the mower can change a required installation.[6]

Finding an access box is useful even when its lid gives no clear identification. Photograph the closed box, its markings and the surrounding location. Compare those with the utility record. Avoid removing an unknown lid, especially one belonging to electrical, gas or utility equipment.

My call: find and photograph the access while the drains work. Save that location with the utility’s contact details and your earlier service reports so it is easy to find when you need help.

Is it a cleanout, a cover or another fitting?

Cover and plug differ Trim cover Finished surface Plug Drain fitting Schematic only; parts vary.
A trim cover provides access to the plug; the plug closes the drainage opening. This is a schematic distinction, not a drawing of the Sioux Chief product. IPC 2021 section 708.1.11.1 addresses purpose-made trim covers.[1]
A plug in an identified drain fitting

A raised head, recessed square or slot can be the tool interface.[1] Match the opening to the drain route and fitting marks before calling it the main sewer access.

A round floor or wall plate

It may hide the actual cleanout plug. Replacing a decorative plate does not replace the closure behind it.[1]

A wing nut and rubber seal

It may be a mechanical test plug. Identify its model and instructions rather than treating it as a threaded replacement cap.

A chamber or large utility lid

Do not enter it or work below the opening. Sewer and septic spaces can expose a person to hazardous atmospheres; use qualified help.[11]

A small branch cleanout and a main-line cleanout can both have slotted plastic plugs. The slot alone does not identify which drains the fitting serves. Trace only the pipe you can see and use plans for the concealed section. Record uncertainty instead of guessing from cap color.

A cover screw is another clue, but it is not a pipe-size measurement. The Sioux Chief 878-20 has a threaded brass insert according to the maker’s product page. Its insert is a separate feature from the plug’s outside threads, which fit the drainage opening.[2]

Leave a grating over a floor drain in place during this search. A floor drain receives water, while a cleanout provides service access through a closure. If the opening is unfamiliar, a picture of its surroundings is more useful than taking it apart to find out.

How to approach opening a cleanout safely

A blocked line is a stop condition. Do not remove its cap to release sewage or test whether the line is full.

  1. Stop water use if drains are backing up

    Stop flushing and using connected sinks, showers and laundry. Tell everyone in the building. If wastewater continues to rise, contact the sewer utility and a licensed plumber; closing a fixture faucet does not isolate a backed-up sewer.

  2. Keep the fitting closed while you assess the site

    Do not loosen a cap that is leaking, bulging or associated with standing wastewater. Stay clear of its face and keep children and pets away. Do not use the opening as a pressure-release point.

  3. Confirm the fitting and instructions for routine access

    For a freely draining line, identify the plug, fitting and removal method first. Arrange a plumber if you cannot verify them. There is no universal tool or tightening torque for all plastic, brass and cast-iron cleanouts.

  4. Prepare for splash exposure

    CDC recommends goggles, a protective face mask or splash-proof face shield, liquid-repellent coveralls, waterproof gloves and rubber boots for sewage-handling work.[8] Cover cuts and arrange handwashing.[8] PPE does not make a backed-up cap safe to open.

  5. Let a professional handle resistance or uncertainty

    If the cap will not move with its specified tool and procedure, stop. Do not add heat, strike the fitting, cut the plug or improvise a longer handle. A seized closure can turn an access job into a pipe repair.

  6. Restore the correct closure after service

    Follow the exact plug and fitting instructions for reinstallation and sealing. Confirm the closure is secure and there is no leakage before returning the area to normal use. Do not leave a temporary test device in place without approval for that use.

Chemical drain cleaner is present

Tell the plumber the product name and when it was added before any access work. Avoid splashes and do not mix cleaners; Drano’s precautions warn of hazardous fumes or a violent reaction.[10] Follow the product label’s exposure and emergency directions if a splash occurs.[10]

Sewage near electrical equipment

Stay out of the wet area and keep others away. CDC says not to enter standing water to reach the main power switch.[9] Call an electrician to turn off power when access is wet; do not reach through water to unplug equipment.[9]

Strong gas odor or an enclosed pit

Leave the area and arrange qualified assessment. Do not put your face into the opening or rely on an open window to make a sewer space safe.[11]

For a homeowner, finding the cleanout and giving the plumber a clear route to it can be the whole useful job. A capped access point does not have to be opened to photograph it or note its position. Keep a basement path clear without moving electrical equipment into a damp area.

If sewage is already escaping, keep people out of the affected area. The utility may need to check the public sewer as well as the plumber’s check of the private lateral. Tell both parties which fixtures are affected and when the overflow started, without removing another cap.

Before operating a powered drain machine, match the cable to the drain and follow the exact machine’s instructions for setup and safe use. My drain-cleaning-machine guide explains equipment choices. A machine purchase does not establish that a blocked cleanout is safe to open.

Threaded plugs for a confirmed fitting

The 2, 3 and 4 in. plugs below are fit-specific options.[2][3] Finding a cleanout tells you where it is, not its size, so match the fitting before you pick one.

PlugKey specsPick it ifSkip it if
Sioux Chief 878-20, 2 in. threaded plug878-20, 2 in. MIP thread, White, Slotted head, Polypropylene per maker, 1/4-20 brass insert[2]The existing fitting is confirmed to accept the 2 in. threaded 878-20, and its sealing and installation instructions are available.[2]You need a 3 or 4 in. main-line plug, an expansion test plug, a cover plate alone, or a closure for damaged threads.[3]
Sioux Chief 878-30, 3 in. threaded plug878-30, 3 in., White, Slotted head, Polypropylene per maker, 1/4-20 brass insert[3]The existing fitting is confirmed to take a 3 in. threaded plug, and its threads are sound.[3]The fitting isn’t a confirmed 3 in. threaded opening, the threads are damaged, or you need a test plug or cover plate.[3]
Sioux Chief 878-40, 4 in. threaded plug878-40, 4 in., White, Slotted head, Polypropylene per maker, 1/4-20 brass insert[3]The existing fitting is confirmed to take a 4 in. threaded plug, and its threads are sound.[3]The fitting isn’t a confirmed 4 in. threaded opening, the threads are damaged, or you need a test plug or cover plate.[3]

Sioux Chief 878-20 for a 2 in. cleanout[2]

Three sizes of one Sioux Chief plug: the fitting decides, so none of the three is scored. All three were new and in stock on November 15, 2026.[2][3]

Sioux Chief 878-20 white 2 inch slotted cleanout plug
Sioux Chief 878-20, 2 in. threaded plug. Product photo: Amazon.

The 878-20 belongs on the shortlist only after the opening has been identified as a matching 2 inch threaded cleanout.[2] That makes it a branch-fitting option here, rather than a default purchase for the main sewer access you have just found beside the house. Confirm the old part and fitting before choosing it.

Sioux Chief lists this exact model as a white, slotted plug in reinforced polypropylene with a threaded brass insert.[2] The maker says the material won’t seize up on ABS or PVC and is chemical-resistant.[2] That matters on a closure that may sit untouched until a drain needs service.

The brass insert is relevant if the assembly uses a cover fastener. Sioux Chief lists it as a 1/4-20 thread.[2] That does not make this a brass pipe plug, and it does not establish that an existing cover screw will fit. Check the assembly’s own part information before transferring a screw or cover.

Where it does well

  • Maker identifies 878-20 as a 2 in. white slotted plug[2]
  • Threaded brass insert, 1/4-20 per Sioux Chief[2]
  • Maker says its polypropylene won’t seize on ABS or PVC[2]

What to watch

  • Needs compatible thread sealant or tape, per Sioux Chief[4]
  • Does not cover every main-line cleanout size
  • Thread and fitting match still need confirmation

Sioux Chief specifies a 2 inch MIP thread for size code 20 in this series.[4] The series is for PVC/ABS or cast iron drain, waste and vent systems.[4] That does not confirm the size or condition of an unknown fitting. Save the old plug and its markings; have an uncertain match identified before replacement.

A slotted head also changes what must be accessible when the closure needs service. Keep room for the specified removal tool and avoid covering the access with permanent flooring.[1] The correct plug can still leave a poor installation if nobody can reach its head without dismantling a cabinet.

My call: use the 878-20 for a verified matching threaded fitting with intact threads.[2] Skip it when the opening requires a rubber expansion seal or a different nominal size. A plug that starts crooked or needs force to engage is a reason to stop and recheck the fit.

The maker specifies compatible thread-sealing compound or tape, installation into female threads, and no overtightening.[4] Check sealant compatibility with the fitting material before use. A leak at the closure needs a fit and condition check; extra force can damage the connection instead of correcting the cause.

Sioux Chief’s spec sheet covers the white 878-20 and the black 879-20 together.[4] In both numbers, size code 20 means a 2 inch MIP thread, and both come with a brass insert.[4] If a supply house hands you the black one, the fit check is the same. The Amazon title names 878-20 and polypropylene, matching the maker.

Sioux Chief 878-30 for a 3 in. cleanout[3]

Sioux Chief 878-30 white 3 inch slotted cleanout plug
Sioux Chief 878-30, 3 in. threaded plug. Product photo: Amazon.

The 878-30 is the same Sioux Chief plug in a 3 in. size, for a cleanout you’ve confirmed takes a 3 in. threaded plug.[3] Sioux Chief lists it as white, slotted and polypropylene, with a 1/4-20 threaded brass insert.[3] The 878-30PK on this listing is the packaged version Sioux Chief lists right beside the 878-30.[3]

Size it from the fitting, not from a guess at the pipe. Read the markings on the old plug or the fitting body and match that nominal size. A plug that starts crooked or won’t thread in by hand is the wrong size or is meeting damaged threads; stop there.

The 2021 IPC, section 708.1.7, allows plastic cleanout plugs that meet the plastic fitting standards and lists a countersunk slot head among the accepted head styles.[1] It limits copper-alloy plugs to metal piping.[1] Sioux Chief’s spec sheet says this series suits PVC, ABS or cast iron drain, waste and vent systems.[4]

Where it does well

  • Maker identifies 878-30 as a 3 in. white slotted plug[3]
  • Threaded brass insert, 1/4-20 per Sioux Chief[3]
  • Maker says it won’t seize on ABS or PVC[3]

What to watch

  • Packaged 878-30PK on this listing[3]
  • Thread and fitting match still need confirmation
  • Listing says PVC; maker says polypropylene[3]

The listing title calls it a “recessed PVC” plug.[3] Sioux Chief’s own page says reinforced polypropylene, which it says won’t seize on ABS or PVC and resists chemicals.[3] I go by the maker; check that the package says 878-30 before you install it.

If a trim cover screws into the plug, the IPC wants a plug made with a blind threaded hole for that screw.[1] This plug’s brass insert is a 1/4-20 thread, so confirm your cover screw matches before you count on it.[3]

Install it the way the spec sheet says: compatible thread sealant or tape, into female threads, and no overtightening.[4] A plug that still weeps after a snug fit needs its threads checked, not more force.

My call: I’ve used Sioux Chief’s 878 plugs, and on a sound 3 in. threaded cleanout this is the plug I’d put back.[3]

Sioux Chief 878-40 for a 4 in. cleanout[3]

Sioux Chief 878-40 white 4 inch slotted cleanout plug
Sioux Chief 878-40, 4 in. threaded plug. Product photo: Amazon.

The 878-40 is the 4 in. size of the same series, for a cleanout you’ve confirmed takes a 4 in. threaded plug.[3] Sioux Chief lists it as white, slotted and polypropylene with a 1/4-20 brass insert, and also makes it in black (879-40) and without the insert (878-040).[3]

A bigger plug doesn’t change the room you need around it. The 2021 IPC asks for at least 18 in. of working clearance in front of cleanouts on pipe 6 in. or smaller, so a 4 in. cleanout behind a water heater or deep in a crawlspace still needs that space to be useful.[1][3]

The listing’s spec lines say PVC. Sioux Chief says polypropylene, and its spec sheet says glass-fiber reinforced. I go by the maker; check that the package says 878-40.

Where it does well

  • Maker identifies 878-40 as a 4 in. white slotted plug[3]
  • Threaded brass insert, 1/4-20 per Sioux Chief[3]
  • Same series in black and no-insert versions[3]

What to watch

  • Black 879-40 and no-insert 878-040 are other part numbers[3]
  • Thread and fitting match still need confirmation
  • Listing says PVC; maker says polypropylene

The listing also suggests pairing these plugs with FIP adapters to make your own cleanouts. That’s a new fitting on the drain, not a plug swap, and it falls under the code your building department enforces.

The open slots are there for installing and removing the plug, so keep the head reachable.[4] Don’t box it in behind flooring or a cabinet back where nobody can turn it.

Seal and tighten it as with the smaller sizes: compatible thread sealant or tape, into female threads, without overtightening.[4] If an old 4 in. plug won’t turn, stop before the fitting cracks and have it looked at.

If a finished floor or wall has a trim cover over a 4 in. cleanout, check its screw against the plug’s 1/4-20 brass insert. Sioux Chief’s 878-040 has no insert, so it gives a cover screw nothing to thread into; pick the 878-40 when a cover goes on.[3]

My call: I’ve used the 878-40, and for a sound 4 in. threaded cleanout on the main line it’s the plug I’d put in.[3]

Match the closure to the job

Part or deviceWhat it doesMain checkDecision
Sioux Chief 878-20 white 2 inch slotted cleanout plugSioux Chief 878-20Threaded closure for a matching 2 in. cleanout[2]2 in. MIP thread; fitting condition and instructions[4]Check it on Amazon
Sioux Chief 878-30 white 3 inch slotted cleanout plugSioux Chief 878-30Threaded closure for a matching 3 in. cleanout[3]3 in. size; fitting condition and instructions[3]Check it on Amazon
Sioux Chief 878-40 white 4 inch slotted cleanout plugSioux Chief 878-40Threaded closure for a matching 4 in. cleanout[3]4 in. size; fitting condition and instructions[3]Check it on Amazon
Trim cover or plateKeeps access through a finished surfaceIdentify the actual plug behind itA plate alone does not close the drain
Mechanical test plugSeals an opening for its documented test applicationExact model, backpressure and installation limitsPermanent use requires exact-device approval
Unknown or damaged fittingNeeds identification or repairCracked body, failed threads or missing markingsArrange identification or repair before replacement

Check the listing against the maker

ModelSupplied Amazon titleOfficial maker descriptionWhat I use
Sioux Chief 878-202" Slotted Polypro Flush Plug w/ Threaded Brass Insert {878-20}[2]2 in. white slotted polypropylene with 1/4-20 threaded brass insert[2]Title and maker agree; confirm model on the packaging before installation
Sioux Chief 878-30 (878-30PK)Sioux Chief Plug RECESSED PVC 3" MfrPartNo 878-30PK[3]3 in. white slotted polypropylene with 1/4-20 threaded brass insert[3]Maker’s polypropylene; confirm 878-30 on the package[3]
Sioux Chief 878-404" Slotted Polypro Flush Plug w/ Threaded Brass Insert {878-40}; spec lines say PVC[3]4 in. white slotted polypropylene with 1/4-20 threaded brass insert[3]Maker’s polypropylene; confirm 878-40 on the package[3]

The listing title is kept for identification. Material and insert details follow Sioux Chief’s 878-20 product page, read Oct 21, 2026. Check that the bag or label says 878-20 before installation.

Where code requires cleanout access

The figures below are a 2021 IPC reference.[1] The adopted edition, local amendments and utility standards decide what applies to your property.

Location or condition2021 IPC reference[1]Limit or requirement
Horizontal drains and building drains708.1.1[1]Cleanout intervals no more than 100 ft, with stated exceptions[1]
Building sewer smaller than 8 in.[1]708.1.2[1]Cleanout intervals no more than 100 ft[1]
Building drain / building sewer junction708.1.3[1]At junction or within 10 ft upstream along the pipe[1]
Horizontal direction change greater than 45 degrees[1]708.1.4[1]Cleanout at change; first may serve qualifying changes within 40 ft[1]
Working clearance, pipe 6 in. or smaller[1]708.1.10[1]At least 18 in. perpendicular to opening[1]
Working clearance, pipe 8 in. or larger[1]708.1.10[1]At least 36 in. perpendicular to opening[1]
Required access708.1.11[1]No concealed required cleanouts; below-grade access extended to grade[1]

Read the table as a reference for a particular code edition. A house built under an earlier adopted code, or located in a jurisdiction using another code family, needs a local check. Ask the building department which rule applies before calling a missing exterior cap a violation.

The junction distance is measured along the pipe upstream of the building-drain and building-sewer junction.[1] It is not a ten-foot search circle around every foundation. An old addition can also change what looks like the outside wall today. A drawing helps separate those two questions.

The code table describes required access. The search diagram describes places to investigate. Neither establishes the surveyed location, condition or legal compliance of an unseen pipe.

Use the location, evidence and next-action chart

Where you are lookingEvidence to collectNext action
Basement stack or drain exitPhoto of closed cap, visible pipe route and wall locationKeep access clear; compare with inspection records
Slab-house exterior wallCapped riser or labeled access box on a documented drain routeConfirm it serves sanitary drainage before opening
Property line or alley sideUtility lateral record plus a matching visible featureAsk utility which access points it maintains
Shrubs, soil or finished floorOld inspection photo or recorded access locationHave buried or concealed access located and corrected
No visible cleanout anywhereHouse plan, lateral record and earlier service reportArrange a locating assessment instead of random digging
Sewage visible at any capTime, affected fixtures and photo taken from a dry safe spotFollow the backup stop steps above

Keep a location note with a photograph taken from a fixed landmark, such as the basement stairs or a foundation corner. Use your own measurements when you make the note. A description like “near the front” becomes ambiguous after landscaping changes or when someone approaches from a side gate.

If a service report identifies more than one access, label each separately. Record which one is inside, which is at the property line and which route the technician confirmed. Do not label a fitting “two-way” merely because another capped riser stands beside it.

Before any excavation, contact 811 and follow your state’s notice and clearance process.[12] PHMSA advises contacting 811 before digging.[12] Ask the utility which facilities its locate covers; arranging a sewer-lateral assessment is a separate question from receiving utility markings.

For a shared building or rented home, give the property manager the location note. Water use elsewhere in the building can affect the drain while you are looking at it. That is another reason a resident should not treat a closed cap as a way to test whether the sewer is blocked.

Keep the cleanout usable after you find it

Keep a clear service route

Leave space to reach the closure and bring equipment to it. A closed storage cabinet can be moved before an emergency; permanent construction needs a planned access detail.

Preserve a required raised cap

Check utility rules before changing a yard riser. Anne Arundel County explains that its raised configuration helps locating and limits unwanted water and sediment entry.[6]

Use the specified floor assembly

A flush surface and an accessible closure need a suitable assembly. Do not bury the plug under flooring or assume a decorative plate is rated for vehicle loads.[1]

A landscaping project is a good time to mark the cleanout position on the plan. Keep irrigation, pavers and planting work from blocking access. If the height needs changing, have the proposed detail checked before any pipe is cut; a riser and its seal are parts of the drainage system.

A sewer-cleanout cap is not an overflow control. Leaving it loose to avoid an indoor backup creates another sewage opening and does not repair the obstruction. The next useful step is a diagnosis of the private lateral and, when appropriate, the public system.

If the same drain keeps blocking, locating the access is only the start. Save the findings from the service visit, including any confirmed defect. My guide to recurring main-drain clogs covers the follow-up questions, while the sewer-inspection-camera guide explains the equipment category.

Questions about drain cleanout locations

Where is my sewer cleanout most likely to be?

Start near the basement drain stack and the drain’s exterior-wall exit, then check the recorded sewer route toward the property line.[5][6] Basement and yard arrangements vary. Utility records and earlier inspection reports can narrow the search without opening the cap.

Does every house have an outside cleanout?

Do not assume it does. Minneapolis notes that access near the outside wall may be inside or outside.[5] A cap may also be hidden by soil or finished surfaces. Ask for locating help if records and a visual search do not identify it.

How far from the house should a cleanout be?

There is no single yard distance to use for every house. The 2021 IPC junction rule allows access at the building-drain and building-sewer junction or within 10 feet upstream along the pipe.[1] That does not mean every cap stands ten feet outside the foundation.

Can I open a cleanout during a sewer backup?

Leave it closed. Stop water use and arrange help from the sewer utility and a licensed plumber. Removing a closure can expose you to sewage; use a dry safe location to report the symptoms instead of using the cap to release the blockage.

Is a floor cover the same thing as a cleanout plug?

A trim cover can conceal the actual plug beneath it.[1] The plug closes the drainage opening; the cover provides finished access. Identify both parts before buying a replacement, and do not assume a cover plate alone will stop leakage or gas.

Can a mechanical test plug replace a threaded cap?

Only use a device for the application its exact instructions and local approval allow. A test plug is not automatically approved as a permanent closure. Match the original fitting’s closure, and have damaged threads or an uncertain assembly assessed.

What if the cleanout is buried?

Ask the utility for lateral records and arrange a plumber’s locating assessment. Do not excavate blindly or cut a cap down before checking local requirements. After locating it, have the access detail corrected so it remains reachable.

Will the Sioux Chief 878-20 fit my main cleanout?[2]

Only if the fitting is confirmed to accept that exact 2 inch threaded plug. It is not a universal main-line cap. Sioux Chief lists it as a 2 in. MIP plug in reinforced polypropylene; check the model on the packaging before installation.[2][4]

Why trust this guide and how I choose

Why trust this guide

Isaac Daniels is the named author and a licensed journeyman plumber in Georgia. I separate the 2021 IPC reference from local utility examples, and distinguish a visible search clue from a confirmed pipe location.[1]

How I choose

I compare the maker’s exact model with the Amazon offer, then check what job the part actually fits.

The 878-20, 878-30 and 878-40 are conditional fit choices: the size has to match the fitting. I re-read all three offers through the Amazon on November 15, 2026; all three were new and in stock.[2][3] I use official sources for the technical statements and do not turn a stock listing into a performance score.

On November 15, 2026, CPSC’s recall search returned no recalls for Sioux Chief.

Selection checkRule used here
IdentityExact brand and model must match maker information
FitKnown fitting size and connection before replacement
UseThreaded closure separated from test equipment and trim cover
OfferNew, in-stock Amazon offer for each size checked Oct 22, 2026
PriceAmazon price display only; check Amazon when no current price is available
ScoringNo numerical score for a fit-specific closure

Sources

Official documents and offer record

  • International Code Council, 2021 International Plumbing Code, chapter 7, section 708, including 708.1.7 (plug materials and heads) and 708.1.10 (clearance); official indexed chapter text read Oct 20, 2026. Reference edition only; local adoption must be checked. Read source
  • Sioux Chief, 878-20 product page: 2 in. white slotted polypropylene cleanout plug with threaded brass insert, 1/4-20 insert thread; reinforced polypropylene will not seize up on ABS or PVC. Read Oct 21, 2026. Read source
  • Sioux Chief, 878-30 and 878-40 product pages: 3 and 4 in. white slotted polypropylene plugs with 1/4-20 threaded brass insert; 878-30PK packaged version; 879-40 black and 878-040 no-insert versions. Read November 15, 2026. Read source
  • Sioux Chief, 878 & 879 Series slotted cleanout plug specification, 3-18 revision. Size code 20: 2 in. MIP thread; PVC/ABS or cast iron DWV use; compatible thread sealant or tape; install into female threads without overtightening. Read Oct 20, 2026. Read source
  • City of Minneapolis, Sewer cleanouts, updated April 17, 2023; read Oct 20, 2026. Basement, exterior-wall and hidden-access guidance. Read source
  • Anne Arundel County Department of Public Works, Sewer Cleanouts; read Oct 20, 2026. Property-line location, records and local raised-cap requirements. Read source
  • Lake County Special Districts, Sewer Lateral Cleanout FAQ; official indexed text read Oct 20, 2026. Lateral records and locating assistance.
  • CDC, Protecting Workers Handling Human Waste, April 22, 2024. Splash PPE, handwashing and exposure precautions. Read source
  • CDC, What to Do to Protect Yourself From Electrical Hazards, reviewed Aug 26, 2026. Wet electrical equipment and standing-water precautions; read Oct 20, 2026. Read source
  • SC Johnson, Drano Kitchen Gel, precautions. Splash exposure and hazards from mixing cleaners; read Oct 20, 2026. Safety source only.
  • OSHA, Sewer System Entry, appendix E to 29 CFR 1910.146. Hazardous atmospheres and sewer-entry precautions. Read source
  • PHMSA, Call Before You Dig! Contact 811 before excavation and follow the applicable notice process. Read source
  • Amazon offers, November 15, 2026: 878-20, 878-30PK and 878-40; all new and in stock. CPSC recall search (saferproducts.gov), same day: Sioux Chief 0. Read source