SharkBite vs ProPress

SharkBite vs ProPress comes down to the pipe and the repair. I’d press a permanent copper run with Viega ProPress; I’d choose SharkBite Max for a mixed-pipe repair without a press tool.

As an Amazon Associate I earn from qualifying purchases. How this site earns

Updated November 15, 2026 · Warranty conditions and repair guidance clarified.

Copper water supply, shutoff valves and a pressure regulator inside an open wall
An open wall shows why pipe access and room for tools matter. This is a job photo, not a photo of the listed picks.

The short answer

I’d choose ProPress for permanent copper work when the correct press tool fits. SharkBite Max joins compatible mixed pipe without that tool. Both need careful pipe preparation and testing. [1] [4]

Copper to copper
Viega 78047, with compatible ProPress tooling. [4] [8]
Copper to PEX or CPVC
SharkBite Max UR008A, sized for the pipe. [1] [4]
One repair, no press tool
Max avoids buying a press tool. Cut, deburr and mark first. [1] [4]
Find the joint that fits

Find your joint

I start with pipe material, tool access and where the joint will sit.

Choose the pipe, tool access and location above.

This finder cannot replace a pipe inspection, pressure test or local-code check. Use a plumber for unknown pipe or a concealed repair you cannot inspect, and an electrician for bonding.

The parts and tools compared

I compare one fitting from each system, the RP 115 press-tool bundle and a depth gauge. They do different jobs: the fittings join the pipe, the press tool closes ProPress joints, and the gauge marks SharkBite depth. [1] [4] [5] [6]

Viega ProPress half inch copper coupling with stop and green Smart Connect dot
Photo from the Amazon listing.
Best for copper you’ll close in

Viega ProPress ½ in. coupling with stop (78047), 5-pack

Check Viega 78047 on Amazon

Seller: The Portland Group. New offer checked November 15, 2026. Check price on Amazon. This is a third-party seller.

Buy it if: You are joining sound copper and have compatible ProPress jaws and room to use them. [4] [8]

Skip it for plastic pipe or a joint you need to disconnect. This fitting needs a press tool. [4]

The Amazon offer is a five-pack. Viega’s catalog lists a quantity of 10 for part 78047; I keep those pack descriptions separate. Confirm the listing pack count before ordering. [8] [12]

SharkBite Max half inch brass push-to-connect coupling
Photo from the Amazon listing.
Best for a fast repair on mixed pipe

SharkBite Max ½ in. push coupling (UR008A)

Check SharkBite UR008A on Amazon

Seller: Amazon.com. New offer checked November 15, 2026. Check price on Amazon.

Buy it if: You need a compatible mixed-pipe connection without a press tool. [1] [2]

Skip it on galvanized tube or for a joint within a slab. Prep and full insertion still matter. [1]

RIDGID RP 115 mini press tool kit with case, battery and jaws
Photo from the Amazon listing.
Best for ½ and ¾ in. ProPress repairs

RIDGID RP 115 kit 72553 with 223S reamer 29983

Check RIDGID RP 115 bundle on Amazon

Seller: Amazon.com. New offer checked November 15, 2026. Check price on Amazon.

Buy it if: Your copper repairs use the included half-inch and three-quarter-inch ProPress jaws. [5] [7]

Skip it for larger copper joints. The listed bundle adds a 223S reamer; it is separate from the RP 115 tool. [5] [12]

SharkBite UR702A depth gauge and deburring tool for half to one inch pipe
Photo from the Amazon listing.
Best for marking SharkBite depth

SharkBite depth gauge and deburr tool (UR702A)

Check SharkBite UR702A on Amazon

Seller: Amazon.com. New offer checked November 15, 2026. Check price on Amazon.

Buy it if: You need the Max insertion mark for half-inch, three-quarter-inch or one-inch pipe. [6] [11]

Skip it for larger pipe. This deburrs the outside; ProPress also requires the inside edge to be deburred. [4] [6]

ToolKey specsPick it ifSkip it if
Viega ProPress ½ in. coupling with stop (78047), 5-packThis fitting: ½ in. press × press with stop, copper body, EPDM seal, part 78047. System figures and warranty conditions appear below. [8] [4]You’re joining copper and the wall, ceiling or ground is about to close over it. You want a joint that stays put and passes bonding through. [8] [4]You’re joining PEX, CPVC or HDPE, or you need to connect two different pipe types. ProPress fittings are for copper tube. [8] [4]
SharkBite Max ½ in. push coupling (UR008A)This fitting: ½ in. coupling, DZR brass body and EPDM O-ring. RWC calls the catalog item UR008; the Amazon listing is UR008A. [1] [2]You need water back on fast, the line is still wet, or you’re joining PEX to copper or CPVC. No press tool, no torch. [1] [2]The pipe is galvanized, the joint would sit inside a slab, or you’re planning a whole copper run you’ll close in. RWC’s own guide rules out the first two. [1] [2]
RIDGID RP 115 mini press tool kitRIDGID 72553, 12V Li-ion, ½ and ¾ in. jaws, 210° swivel, Case included; this bundle adds the 223S reamer (29983), ¼ to 1 ¼ in. [5] [12] [13]Most of your copper is ½ and ¾ in. water line, and you want press joints on repairs without hauling a full-size tool. [5] [7]You press 1 in. and up often. My press tool guide covers the RIDGID RP 251 and RP 351 and Milwaukee’s M12 and M18 tools. [5] [7]
SharkBite depth gauge and deburr tool (UR702A)UR702A depth gauge for ½, ¾ and 1 in. pipe, with Max and first-generation marks and an outside deburring wheel. [6] [11]You install SharkBite Max at ½, ¾ or 1 in. and want the depth mark right every time. That mark is how you know the pipe reached the stop. [6] [11]Your pipe is 1 ¼ to 2 in. RWC sells a separate gauge for those sizes. And for ProPress, use a reamer that cleans the inside too. [6] [11]

Pressure and heat each one is rated for

Push and press are different kinds of joint, so the trade-offs below matter more than any one number. These are the two numbers people ask about, straight from each maker’s documents. [1] [2] [4]

SharkBite Max on copper, pressure400 psiProPress system, operating pressure300 psiSharkBite Max, top temperature200°FProPress EPDM seal, top temperature250°FSharkBite Max on copper, pressure400 psiProPress system, operating pressure300 psiSharkBite Max, top temperature200°FProPress EPDM seal, top temperature250°F
Sources: SharkBite Max installation guide and spec sheet; Viega ProPress installation manual IM-PP.

Side-by-side, check by check

Every row comes from RWC’s or Viega’s own manuals, spec sheets, product pages or warranty. The last column says which comes out ahead, where one does. On a phone, each row stacks with its column labels. [1] [2] [3] [4]

CheckSharkBite MaxViega ProPressAhead
Pipe it joinsPEX, copper, CPVC, PE-RT, HDPE SDR-9, any mix [1] [2]Copper tube only (B88, B75) [4]SharkBite [1] [2] [3] [4]
Sizes½–2 in. [1] [2]½–4 in. [4]ProPress [1] [2] [3] [4]
Soft copperWarranty names hard drawn K, L, M [3]½–1 ¼ in. allowed [4]ProPress [1] [2] [3] [4]
Tool to make the jointNone [1] [2]Press tool and jaws [4]SharkBite [1] [2] [3] [4]
Wet lineYes, test right away [1] [2]Yes, wet or dry [4]Even [1] [2] [3] [4]
Pressure rating400 psi on copper [1] [2]300 psi operating [4]SharkBite [1] [2] [3] [4]
Top temperature200°F [1] [2]250°F (EPDM) [4]ProPress [1] [2] [3] [4]
Drinking waterMaker lists: NSF 61 and 372 [1] [2]Maker lists: NSF 61 and 372 [4]Even [1] [2] [3] [4]
Behind the wallMaker lists: Yes, no access panel (ASSE 1061) [1] [2]Yes, concealed spaces [4]Even [1] [2] [3] [4]
BuriedYes, with silicone wrap [1] [2]Yes, with local approval [4]Even [1] [2] [3] [4]
Electrical bondingNot continuous; add a jumper [1] [2]Continuous (UPC 1211.15) [4]ProPress [1] [2] [3] [4]
Taking it apartClip, tongs or pro tool [1] [2]Can’t; it’s non-detachable [4]SharkBite [1] [2] [3] [4]
Space between fittings1 in. for removal [1] [2]0 in. at ½–1 in. [4]ProPress [1] [2] [3] [4]
Finding a missed jointDepth mark within 0.005 in. [1] [2]Smart Connect leaks at low pressure [4]ProPress [1] [2] [3] [4]
Pipe in the fitting, ½ in.1 in. [1] [2]¾ in. [4]ProPress [1] [2] [3] [4]
Galvanized pipeNot allowed [1] [2]Copper only; dielectric union to steel [4]Neither [1] [2] [3] [4]
Warranty25 years [3]50 years [4]ProPress [1] [2] [3] [4]

Sources for each row are listed at the bottom of the page. “Ahead” means ahead on that one check, not overall. A 400 psi rating doesn’t make SharkBite the better joint for a wall you’re closing in, and a 50-year warranty doesn’t help if the pipe is PEX. [1] [2] [3] [4]

Which pipe each one joins

This is the first question, because it settles a lot of jobs before anything else matters. [1] [2] [3] [4]

PipeStandard RWC namesSharkBite MaxViega ProPress
Copper, hardASTM B88 K, L, M [1] [2]Yes [1] [2]Yes, ½–4 in. [4]
Copper, softASTM B88 [1] [2]Warranty table names hard drawn [1] [3]Yes, ½–1 ¼ in. [4]
PEX, 1 in. and underASTM F876, CSA B137.5 [1] [2]Yes, no liner [1] [2]Not a ProPress pipe [4]
PEX, 1 ¼ in. and upASTM F876, CSA B137.5 [1] [2]Yes, with a tube liner [1] [2]Not a ProPress pipe [4]
CPVCASTM D2846, CSA B137.6 [1] [2]Yes [1] [2]Not a ProPress pipe [4]
PE-RTASTM F2769 [1] [2]Yes [1] [2]Not a ProPress pipe [4]
HDPE SDR-9ASTM D2737 [1] [2]Yes, with a stiffener [1] [2]Not a ProPress pipe [4]
Galvanized steelNone [1] [2]Not allowed [1] [2]Not a ProPress pipe [4]

From RWC’s SharkBite Max installation guide, Max spec sheet and limited warranty, and Viega’s ProPress manual IM-PP. RWC says HDPE needs a tube stiffener sold by the HDPE maker. Viega makes a separate stainless ProPress line for 316 stainless tube. [1] [2] [3] [4]

If the job joins two pipe types, SharkBite is the only one of the two that does it in one fitting. A PEX branch off a copper line, or a CPVC repair tied into copper, is exactly what RWC built Max for. [1] [2] [3] [4]

If the pipe is copper on both sides, the choice opens up, and the rest of this page is about that case. If you’re on galvanized, neither belongs on the pipe itself. RWC rules SharkBite out, and Viega’s steel system is MegaPress, which my MegaPress vs ProPress guide covers. [1] [2] [3] [4]

How much pipe and room each joint needs

I put the pipe depths and tool clearances together so you can check both before buying. Repairs fail on two things: not enough pipe in the fitting, and not enough room around it. Here are both, size by size, from the makers’ own tables. [1] [2] [4] [9]

SizeSharkBite Max depthSharkBite 1st gen depthProPress minimum depthProPress no-stop coupling, maxProPress jaw room, side A / B
½ in.1 in. [2]15/16 in. [9]¾ in. [4]⅞ in. [4]¾ in. / 1 ⅝ in. [4]
¾ in.1 ¼ in. [2]1 ⅛ in. [9]⅞ in. [4]1 ⅛ in. [4]⅞ in. / 2 ⅛ in. [4]
1 in.1 ½ in. [2]1-5/16 in. [9]⅞ in. [4]1 ⅛ in. [4]1 in. / 2 ½ in. [4]
1 ¼ in.1 ⅞ in. [2]1 ⅞ in. [9]1 in. [4]1-3/16 in. [4]1 ⅛ in. / 2 ⅞ in. [4]
1 ½ in.2-1/16 in. [2]2-1/16 in. [9]1-7/16 in. [4]1-9/16 in. [4]1 ¾ in. / 3 ½ in. [4]
2 in.2-3/16 in. [2]2-3/16 in. [9]1-9/16 in. [4]1 ¾ in. [4]2 in. / 4 ⅜ in. [4]

SharkBite depths: RWC’s current Max sheet for Max, and the older piping-guide chart for first-generation fittings. ProPress depths and jaw room: Viega IM-PP Tables 19, 1 and 4. Jaw room is Viega’s Table 4 for standard jaws; A and B are the two minimum clearances its diagram shows around the fitting. [1] [2] [4] [9]

SharkBite Max, ½ in.1 in.ProPress, ½ in.¾ in.SharkBite Max, ¾ in.1 ¼ in.ProPress, ¾ in.⅞ in.SharkBite Max, ½ in.1 in.ProPress, ½ in.¾ in.SharkBite Max, ¾ in.1 ¼ in.ProPress, ¾ in.⅞ in.
Insertion depths from RWC and Viega.

Two things jump out. SharkBite Max takes more pipe than ProPress at every size, about a quarter inch more at ½ in. and three eighths more at ¾ in. On a short stub out of a wall, that can decide it. [1] [2] [4] [9]

The other is spacing. RWC says to leave at least 1 in. between Max fittings so a clip can get in later. Viega allows zero between ProPress fittings at ½ to 1 in., but the jaws need the room in the last column to close. [1] [2] [4] [9]

The depth change also catches people with old habits. If you learned on first-generation SharkBite, your ½ in. mark was 15/16 in. Max wants 1 in. RWC says to measure and mark the new depth before you install, and a gauge made for Max does it for you. [1] [2] [4] [9]

For a ProPress repair in a tight bay, look at a no-stop coupling. Viega gives a minimum and a maximum depth for those, and says to mark both with a line joining the two marks. [1] [2] [4] [9]

Which joint for which repair

I start with the repair rather than the brand. This table sorts it by the job instead, using only what each maker allows. [1] [2] [4]

Your jobUseWhy, from the makers
Burst ½ in. copper, water still drippingSharkBite Max [1] [2] [4]RWC says Max goes on wet lines and can be tested right away [1] [2] [4]
PEX branch off a copper lineSharkBite Max [1] [2] [4]One coupling joins PEX to copper; ProPress is copper only [1] [2] [4]
New copper run, wall closing next weekProPress [1] [2] [4]Non-detachable joint, Smart Connect test, 50-year warranty [1] [2] [4]
Copper water line that’s part of the bonding pathProPress [1] [2] [4]Press keeps electrical continuity; Max needs a jumper [1] [2] [4]
Copper joint next to a fresh solder jointEither, with distance [1] [2] [4]Max: solder first. ProPress: Viega’s distance table [1] [2] [4]
Buried copper or PEX serviceEither, by code [1] [2] [4]Max: silicone wrap. ProPress: local approval for underground [1] [2] [4]
Joint inside a concrete slabNo Max joint in the slab [1] [2] [4]RWC calls for continuous PEX. Viega requires corrosion protection and local approval for its application. [1] [2] [4]
Galvanized steelNeither [1] [2] [4]RWC rules Max out; ProPress is for copper [1] [2] [4]
Temporary cap during a remodelSharkBite Max [1] [2] [4]Comes off with a clip; RWC says disconnect only once [1] [2] [4]
Above 2 in. through 4 in. copperProPress [1] [2] [4]Max stops at 2 in.; ProPress covers copper through 4 in. [1] [2] [4]
You own no press tool and need one jointSharkBite Max [1] [2] [4]No tool to make the joint [1] [2] [4]

My call from RWC’s and Viega’s documents. I’ve installed ProPress, so that side is also my own experience. The SharkBite side comes from RWC’s manual, spec sheet, warranty and product pages. [1] [2] [4]

I’d choose between the first three rows by pipe type and tool access. With the supply shut off and pressure relieved, a wet line can still take Max. I’d press sound copper before closing the wall when the jaws fit. [1] [2] [4]

The slab row is the one people miss. RWC’s guide says not to allow joints within a slab at all, and to run continuous PEX and check for leaks before the pour. [1] [2] [4]

Taking a joint apart and reusing it

Shut off the water and relieve pressure before disconnecting a fitting. For hot water, let the line cool. [16]

This is where the two systems differ most. SharkBite is built to come off. ProPress is built not to. [1] [4] [10]

  1. Fit the clip

    Put the SharkBite disconnect clip around the pipe, unbranded face against the release collar. With tongs, the logo end goes around the pipe. [1] [4] [10]

  2. Push and twist

    Push the clip against the collar and pull the pipe with a twisting motion. Tongs: squeeze with one hand, twist and pull. [1] [4] [10]

  3. Inspect

    Check the fitting and pipe end for damage, debris and marks. If the pipe is marked, cut it back and use new pipe. [1] [4] [10]

  4. Before any reuse

    RWC’s five checks: use a clip or tongs, inspect the fitting, clean pipe with no scratches or burrs, mark the depth, and pressure test. [1] [4] [10]

QuestionSharkBite MaxViega ProPress
Can it come off?Yes, with a clip, tongs or pro tool [1] [4] [10]No; a pressed joint is non-detachable [1] [4] [10]
Can you reuse it?Meant to be permanent; reuse only after RWC’s five checks [1] [4] [10]No; cut it out and use a new fitting [1] [4] [10]
Can it rotate after install?Yes, per RWC [1] [4] [10]With a tool; repress past 5 degrees [1] [4] [10]
What RWC says about repeat removalDisconnect once; more can loosen the joint [1] [4] [10]Not applicable [1] [4] [10]

RWC’s leak article is blunt on the last row. It says Max is designed for permanent connections, not repeated connection and disconnection, and recommends disconnecting a fitting only once. [1] [4] [10]

RWC’s guide frames removal as the fix for a fitting installed incorrectly. It isn’t a union, so don’t plan on taking it apart again and again. For the full removal steps, see how to remove a SharkBite fitting. [1] [4] [10]

Behind walls, underground and in concrete

Both makers allow concealed and buried joints. Their conditions are different, and that’s where inspections go sideways. [1] [3] [4]

LocationSharkBite MaxViega ProPress
Behind drywallAllowed without access panels, per ASSE 1061 [1] [2]Approved for concealed spaces; protect from puncture [4]
Buried in soilWrap each fitting in silicone tape at least 0.020 in. thick [1] [2]Approved; local code and the inspector’s OK first [4]
Corrosive or contaminated soilNot suitable; RWC lists examples [1] [2]Use Viega’s corrosion-protection guidance and the local authority’s requirements [4]
BackfillNo rocks, debris or sharp objects [1] [2]Per local code [4]
Inside a concrete slabNo joints in the slab [1] [2]Check local approval and corrosion protection [4]
Exposed to freezingProtect from freezing; RWC excludes freeze damage from warranty [1] [2]Protect from freezing; the seal temperature rating is not freeze protection [4]

RWC’s wrap rule is specific. Overlap the tape 1 in. past each end of the fitting and ¼ to ½ in. across it, pull it tight as you remove the film, and cover the fitting completely. The tape bonds to itself in minutes and cures in a few hours. [1] [3] [4]

RWC’s list of contaminated soil includes old service station sites, high nitrogen from animal waste or fertilizer, pH below 6 or above 8, landfill runoff and solvents. On a site like that, keep brass fittings out of the ground. [1] [3] [4]

Soldering or brazing near each joint

Both seals are rubber, so a torch near either joint is a problem. Viega gives distances. RWC gives an order of work. [1] [4]

Tube sizeSolder near an existing ProPress jointBraze near an existing ProPress jointPress near an existing solder jointPress near an existing braze joint
¾ in.2 ¼ in. [4]6 ¾ in. [4]¼ in. [4]1 ½ in. [4]
1 in.3 in. [4]9 in. [4]7/16 in. [4]2 in. [4]
1 ¼ in.3 ¾ in. [4]11 ¼ in. [4]7/16 in. [4]2 ½ in. [4]
1 ½ in.4 ½ in. [4]13 ½ in. [4]⅝ in. [4]3 in. [4]
2 in.6 in. [4]18 in. [4]¾ in. [4]4 in. [4]

From Viega IM-PP Tables 17 and 18. Viega’s rule behind the table: 3 tube diameters when soldering and 9 when brazing near a ProPress joint. At ½ in., pressing near an existing solder joint needs ¼ in. and near a braze joint 1 in. [1] [4]

RWC doesn’t publish a distance for SharkBite Max. Its guide says to make all solder joints first, then the SharkBite connections, and to keep flame away from the fitting because it can heat the pipe. [1] [4]

Viega’s ways to keep a press joint cool: a cold wet rag, a weld blanket, prefabbing the solder joints first, or heat sink gel or spray. If you’re comparing torch work too, see ProPress vs soldering. [1] [4]

Electrical bonding on a copper line

This one isn’t about leaks. It’s about whether the pipe stays one continuous conductor. [1] [4]

ProPress on copper

Viega says the press gives continuous metal-to-metal contact and meets UPC Section 1211.15 and IFGC Section 310. An electrician still tests the bonding. [1] [4]

SharkBite Max on copper

RWC says Max fittings are not electrically continuous. Install a copper jumper cable across the fitting to keep the line grounded. [1] [4]

Skipping the jumper

If the copper line is part of the bonding path, a push fitting without a jumper can break it. Viega’s manual warns an unbonded system can be a shock hazard. [1] [4]

PEX or CPVC with SharkBite

Plastic pipe isn’t a conductor, so the jumper question is about copper runs only. [1] [4]

If you’re cutting a SharkBite into an old copper water line, check where the bonding clamp sits before you cut. A jumper across the new fitting is cheap and RWC calls for it. Bonding itself is an electrician’s sign-off, which Viega’s manual also says plainly. [1] [4]

How to test each joint before you close the wall

TestSharkBite MaxViega ProPress
First checkDepth mark within 0.005 in. of the release collar [1] [2]Smart Connect: unpressed fittings leak at low pressure [4]
Water test rangeTurn the water on and inspect, per RWC [1] [2]15 to 85 psi to find unpressed fittings [4]
Air test rangeNot given in the Max guide [1] [2]½ to 45 psi with leak-detect solution [4]
Full pressure testPer code; ratings 400 psi on copper [1] [2]Up to 600 psi water or 200 psi air after Smart Connect [4]
When you can testRight away, per RWC [1] [2]Right after pressing [4]

Smart Connect is ProPress’s best feature for anyone closing walls. An unpressed fitting leaks inside those low ranges, so one quick test finds the joint you missed. Viega is clear that it doesn’t replace the code’s pressure test. [1] [4]

SharkBite’s check happens before the water comes on: the depth mark. If the mark sits more than 0.005 in. from the collar, the pipe didn’t reach the stop. Push it home before you test. [1] [4]

These are maker test ranges, not a DIY compressed-air procedure. Use a qualified plumber for pressure testing, follow the fitting and pipe instructions, and keep people clear of a pressurized system. Have an electrician verify bonding before a copper line is cut. [1] [4]

Why each joint fails, from the makers

Both makers publish what goes wrong. The lists overlap more than the arguments online suggest. [1] [4] [10]

SharkBite: pipe not fully inserted

RWC’s first cause. Mark the depth and push to the mark. [1] [4] [10]

SharkBite: pipe not prepared

Cut square, deburr and clean. RWC names its depth and deburr tool for this. [1] [4] [10]

SharkBite: pipe pulling on the joint

Support the pipe so it can’t drag on the fitting. RWC points to pipe supports. [1] [4] [10]

SharkBite: too many disconnections

RWC says disconnect only once, or the joint may loosen. [1] [4] [10]

ProPress: wrong insertion depth

Viega says improper depth can leave an improper seal. Mark it and keep the mark visible. [1] [4] [10]

ProPress: skipped deburring

Viega says burrs can damage or twist the seal and shorten the system’s life. [1] [4] [10]

ProPress: wrong jaws or mixed rings

Use jaws made for the fitting. Don’t mix actuators and rings from different makers. [1] [4] [10]

ProPress: rotated after pressing

Past five degrees, Viega says to repress the fitting. [1] [4] [10]

Notice the common thread. Both lists start with depth and prep, not with the fitting. A push joint gives you no second step to catch a bad depth, so the mark matters more. A press joint gives you Smart Connect, which catches an unpressed fitting but not a bad cut. [1] [4] [10]

If you already have a leaking push fitting, my guide to a SharkBite fitting leaking walks through the causes one by one. [1] [4] [10]

Warranty, and what it asks of you

SharkBite Max (RWC)Viega ProPress copper
Fitting warranty25 years [3]50 years, residential and commercial [4]
Pipe it must be used withHard drawn copper K, L, M; PEX F876; CPVC D2846 [3]ASTM B88 or B75 copper [4]
Property damageConditional real-property coverage for an eligible System, up to 10 years; licensed professional installation required [3]Remedies only if all warranty conditions are met [4]
Mixing brandsIntegrated System coverage excludes mixed critical joints; condition 6 permits compliant other-brand pipe with possible coverage limits [3]Use only jaws and rings made for the fitting [4]
ProofProof of purchase, or date of manufacture [3]Per Viega’s limited warranty [4]

On paper ProPress doubles SharkBite’s term. The fine print matters more. RWC’s current warranty, for installs after May 1, 2026, describes conditional real-property coverage for an eligible System within the first 10 years after purchase or project completion, whichever is shorter, with licensed professional installation. [3] [4]

RWC’s integrated System coverage excludes mixed brands at critical connection points. Its condition 6 also allows other-brand pipe and fittings meeting the named standards and third-party certification, with possible limits to term and coverage. I would check both clauses for the planned combination. [3] [4]

RWC lists a separate 5-year term for brass push fittings on HDPE. The 25-year copper, PEX and CPVC row does not establish the same term for every compatible pipe. I would confirm PE-RT coverage with RWC before relying on it. [3]

The tools each joint needs

StepSharkBite MaxViega ProPress
CutRotary tube cutter on copper, shears on plastic [1] [4] [5] [6]Cut square; no flame cutters, grease or oil [1] [4] [5] [6]
DeburrSharkBite depth and deburr tool [1] [4] [5] [6]Inside and outside, to the insertion depth [1] [4] [5] [6]
MarkPermanent marker at the depth from the gauge [1] [4] [5] [6]Marker; keep the mark visible after pressing [1] [4] [5] [6]
Make the jointYour hands, with a slight twist [1] [4] [5] [6]Press tool with ProPress jaws or rings [1] [4] [5] [6]
RemoveDisconnect clip, tongs or pro tool [1] [4] [5] [6]Cut it out [1] [4] [5] [6]
BurySharkBite silicone wrap [1] [4] [5] [6]Per local code [1] [4] [5] [6]

I’ve used the RIDGID 152 tubing cutter and the 227S reamer, and that pair covers the cut and deburr steps for either system on copper. Viega also says to cut at least 4 in. from the vise jaws, so the press area isn’t marked. [1] [4] [5] [6] [15]

For press tools beyond the RP 115, my press tool guide compares the options, and RIDGID ProPress jaws covers which jaw fits which tool. For deburring, see the best deburring tool for copper pipe. [1] [4] [5] [6]

Using both on one job

Plenty of jobs end up with both. Here’s what each maker’s documents allow. [1] [2] [4] [10]

SharkBite to tie PEX into a pressed copper run

Max joins PEX to copper in one fitting. Keep the copper side clean, deburred and marked to Max’s depth. [1] [2] [4] [10]

SharkBite as a temporary cap

Cap a line during a remodel, then remove it with a clip. RWC says to disconnect a fitting only once, and lists five checks before any reuse. [1] [2] [4] [10]

A push fitting in a bonded copper line

Add RWC’s copper jumper across the fitting so the line stays continuous. [1] [2] [4] [10]

Pressing near an old solder joint

Use Viega’s distance table, and check for leftover solder on the tube first. [1] [2] [4] [10]

SharkBite on galvanized

RWC says not to install Max, threaded or push, on galvanized tubing. [1] [2] [4] [10]

Any joint inside a slab

RWC says no SharkBite joints within a slab. Run continuous pipe. [1] [2] [4] [10]

How to choose in four questions

QuestionIf yesIf no
Is every pipe in the joint copper?Keep going [1] [2] [4]Max only for compatible pipe; neither directly on galvanized steel
Will a wall, ceiling or the ground close over it?ProPress, or Max per RWC’s rules [1] [2] [4]Either [1] [2] [4]
Do you own a press tool with the right jaws?ProPress [1] [2] [4]SharkBite Max, or buy the tool [1] [2] [4]
Is the copper part of the bonding path?ProPress, or Max with a jumper [1] [2] [4]Either [1] [2] [4]

If you answer yes to all four, I would press it. For mixed pipe, Max is an option only when both pipes meet RWC’s compatibility requirements. Galvanized steel needs a different transition. Everything between those cases is a judgment about time, tools and the location of the joint. [1] [2] [4]

My call as a plumber who’s installed ProPress: on copper I’m closing in, I press. SharkBite earns its place on wet lines, mixed pipe and temporary caps, which is exactly how RWC markets it for service and repair. [1] [2] [4]

Questions people ask

Why do plumbers say not to use SharkBite?

I can’t speak for every plumber, but RWC’s own leak article lists four causes: pipe not fully inserted, pipe not prepared, pipe pulling on the joint and too many disconnections. Its guide also says Max isn’t electrically continuous, needs 1 in. between fittings, and isn’t for galvanized pipe or joints in a slab. [1] [10]

Do professional plumbers use SharkBite?

RWC markets Max for service and repair and describes conditional property-damage coverage for an eligible System installed by a licensed professional plumbing contractor. My call: I use press on copper I’m closing in, and push fittings for wet lines and mixed pipe. [3] [1]

What are the downsides of using ProPress fittings?

From Viega’s manual: they’re for copper tube only, they need a press tool with jaws made for the fitting, the jaws need room around the pipe, a pressed joint can’t be taken apart, soft copper is limited to ½ to 1 ¼ in., and a fitting rotated past five degrees should be repressed. [4]

How long will SharkBite fittings last on copper?

RWC’s warranty gives brass push fittings a 25-year term with the named copper, PEX and CPVC pipes, subject to its conditions. That warranty term is not a promised service life. Correct install means a square cut, deburred pipe and the depth mark within 0.005 in. of the collar. [3] [1]

Is SharkBite rated higher than ProPress?

On paper, yes for pressure: RWC rates Max at 400 psi on copper, and Viega gives ProPress a 300 psi maximum operating pressure. ProPress’s EPDM seal is rated to 250°F against Max’s 200°F, and Viega allows a 600 psi water test after the Smart Connect check. [1] [4]

Can SharkBite go behind a wall?

Yes. RWC says Max is approved for behind-the-wall installs without access panels under ASSE 1061. Mark the depth, push to the stop, and test before you close the wall. [1] [2]

Can you bury a SharkBite fitting?

Yes, with conditions. RWC requires a self-fusing silicone tape at least 0.020 in. thick around brass Max fittings, clean backfill and soil that isn’t contaminated. It also says no joints inside a concrete slab. [1]

Can ProPress be used on PEX?

No. ProPress joins copper tube to ASTM B88 or B75, and Viega makes a separate ProPress line for stainless. For PEX, SharkBite Max joins it directly, with no tube liner at 1 in. and below. [1] [4]

Do you need a jumper wire with SharkBite on copper?

Yes. RWC’s guide says Max fittings aren’t electrically continuous and calls for a copper jumper cable when you connect a Max fitting to a copper system. A pressed ProPress joint keeps continuity, per Viega. [1] [4]

How I compared them

Why trust me

I’ve installed Viega ProPress, pressed copper with Milwaukee M12 and M18 and RIDGID RP tools, and used the RIDGID 152 cutter and 227S reamer. The SharkBite side comes from RWC’s manuals, spec sheet, warranty and product pages.

How I compare

  • I compare the current RWC and Viega manuals, fitting sheets and warranty terms, alongside RIDGID’s tool instructions.
  • The fittings, press tool and gauge are separate purchases with no shared score: they do different jobs, and a push joint and a press joint trade different things.
  • Where a document is unclear, I say so.
  • I checked the four named Amazon listings on November 15, 2026; each returned a New, in-stock offer. The Viega listing is sold by The Portland Group, while the other three are sold by Amazon.com.
  • I checked the CPSC records available since 2018 on November 15, 2026. No match identified these four picks; RIDGID name matches concerned framing nailers and wet/dry vacuums.

Sources

I checked the maker documents and Amazon offers on November 15, 2026. Certifications named here are the makers’ published listings, rather than independent directory verification.

  1. RWC SharkBite Max installation guide, July 2024
  2. RWC Max fitting sheet, Rev 2.0, October 13, 2026
  3. RWC limited warranty, installations after May 1, 2026
  4. Viega ProPress systems installation manual IM-PP 724607 1125, including limited warranty
  5. RIDGID RP 115 catalog sheet, kit 72553
  6. RWC Max depth and deburr tool instructions
  7. RIDGID RP 115 operator manual
  8. Viega coupling model 2915, part 78047
  9. RWC piping systems installation guide, first-generation depth chart
  10. RWC fitting-failure and repeat-disconnection guidance