What actually limits the pressure in a copper line
People pick Type K for strength. The chart shows how much strength each piece of a ¾ in. line has, from the Copper Development Association’s 2026 handbook.
Rated working pressure at 100°F for ¾ in. tube and for soldered joints from ⅛ to 1 in. Sources: CDA Copper Tube Handbook (2026), Tables 14.3a, 14.3b and 14.4a. The 160 psi line is IPC 2024 section 605.3 for buried water service; the 80 psi line is section 604.8, above which a house needs a pressure-reducing valve.
Every bar is far past what a house sees. Code caps the pressure inside a building at 80 psi; above that, IPC section 604.8 calls for a pressure-reducing valve. Even Type L soft at ¾ in. is rated 582 psi, more than seven times that.
The weak link moves with how you join it. CDA’s handbook says “the lower of the ratings (tube, fitting or joint) will govern.” A line joined with Alloy E solder is rated 710 psi at the joint, below Type L hard tube’s 1,002.
Brazing changes the math too. The heat softens hard tube, so CDA says to use the annealed rating for any brazed or welded line. Brazed ¾ in. Type L drops from 1,002 to 582 psi; Type K drops from 1,466 to 852.
So the wall doesn’t buy you anything a pressure gauge can see in a house. What it buys is more metal to lose before a pinhole: to soil, to a shovel, to grit in the water. That’s why K lives underground and L lives in the walls.
Tube for the trench: water service lines
Best for a buried ¾ in. water service
ICS ¾ in. Type K soft, 60 ft
ICS Industries ¾ in. nominal (⅞ in. OD) Type K soft copper tube, 60 ft coil
Takes flare, compression, solder or press fittings
Cons
About 38 lb for the coil, against 27 lb in Type L
10% less bore area than Type L at ¾ in.
Soft coil has no green print; read the stamp
Sold by a third-party seller, not Amazon.com
¾ in. nominal0.875 in. OD0.745 in. ID0.065 in. wall0.641 lb/ft60 ft coil
Buy it if
You’re running a new ¾ in. water service from the meter or curb stop to the house, under 60 ft, and your water utility accepts or asks for Type K.
Skip it if
The run is indoors. Type L does that job lighter and with more bore; see the VENTRAL ½ in. Type L for branch lines.
ICS Industries makes this 60 ft coil of ¾ in. nominal Type K copper, annealed to the soft temper. It was new and in stock from COPPERTUBINGSALES, a third-party seller, on Oct 21 and once more on Oct 22, 2026. The listing names ASTM B88, the standard for copper water tube, and NSF 61 for drinking water.
Nominal ¾ in. copper measures ⅞ in. outside. That’s true for K, L and M alike, which is why the same fittings fit all three. The difference is inside. CDA’s Table 14.2a gives Type K at ¾ in. a 0.065 in. wall and a 0.745 in. bore.
Type K is the thickest of the three common types. At ¾ in., its wall is 44% thicker than Type L’s 0.045 in. That extra copper is what you’re paying for, and underground is where it earns its keep.
The coil is the other half of the reason. A 60 ft coil can run from the meter to the house wall with no joint buried in the trench. CDA’s own handbook lists soft coils of 60 and 100 ft for Type K from ¼ to 1 in.
Soft tube also handles a freeze better than hard tube. In CDA’s testing, water in ½ in. soft tube froze six times before the tube burst, and 2 in. tube eleven times. CDA calls that a safety factor for underground services and still says not to let lines freeze.
The rating is 852 psi at 100°F in this soft temper, from CDA’s Table 14.3a. Code asks 160 psi of buried service pipe, under IPC section 605.3. CDA’s tested burst average for ¾ in. Type K soft is 4,200 psi.
Weight runs 0.641 lb per foot, so the full coil is about 38 lb of copper. The same coil in Type L would be about 27 lb. More copper per foot is also why K costs more; the live price is on the button.
I’ve used this coil. Unroll it along the trench rather than pulling loops off the side, or it kinks. One point on markings: CDA says hard tube carries a colored print, green for K, but soft coil only has the incised stamp. Read the stamp on the coil before it goes in the ground.
Best for long ½ in. pulls with no joints
Mueller ½ in. Type L soft, 100 ft
Mueller Industries GIDS-12L100 ½ in. Type L soft copper tube, 100 ft
½ in. is under the ¾ in. code minimum for a water service
About 28 lb, a lot to handle in a crawl space
Soft tube sags; it needs more support than hard
Sold by a third-party seller, not Amazon.com
½ in. nominal0.625 in. OD0.545 in. ID0.040 in. wall0.285 lb/ft100 ft coil
Buy it if
You need a long ½ in. run with no joints, such as a line to a detached building’s single fixture, an ice maker loop or a pull through a crawl space.
Skip it if
It’s the main water service. IPC section 603.1 sets ¾ in. as the smallest water service pipe; use the ¾ in. Type K coil.
The GIDS-12L100 is Mueller Industries’ 100 ft coil of ½ in. Type L copper in the soft temper. It was new and in stock from Megamart USA, a third-party seller, on Oct 21 and once more on Oct 22, 2026. The listing gives brand Mueller and the exact model number.
Half-inch Type L measures 0.625 in. outside with a 0.040 in. wall and a 0.545 in. bore, from CDA’s Table 14.2b. Type K at the same size has a 0.049 in. wall and a 0.527 in. bore. On ½ in. tube, the gap between the two is smaller than at ¾ in.
Soft Type L at ½ in. is rated 722 psi at 100°F. That’s about nine times the 80 psi a house is held to under IPC 604.8. CDA’s tested burst average for ½ in. Type L soft is 3,885 psi.
CDA’s own minimum recommendation for buried water services is Type L soft where coils are handier, or Type M hard in straight lengths. Code allows K, L and M underground as long as the pipe is rated 160 psi. So Type L soft is a legitimate service tube in places that allow it.
The catch with this coil is size. IPC section 603.1 says a water service pipe can’t be smaller than ¾ in., so this ½ in. coil isn’t a whole-house service. It’s for the long branch runs where one coil saves you a dozen sweat joints.
Weight is 0.285 lb per foot, about 28 lb for the coil, and it holds about 1.2 gallons of water when full. Soft tube bends by hand, but it also sags between hangers. Support it more often than you would hard tube, and use a bender for tight turns so it doesn’t kink.
Joining is wide open. CDA lists flare and compression fittings for soft tube, along with solder and brazing. Viega’s ProPress guide allows soft tube in sizes from ½ to 1¼ in. Ream every cut end; IPC section 605.13.6 requires cut ends reamed to the full bore.
I’ve used this coil. My call: when a run is long and a joint inside a wall would worry you, a single soft coil is the cleaner job. Mark the stamp side up as you pull, so the next person can read Type L on it.
Tube for the house and for repairs
Best for ½ in. branch lines indoors
VENTRAL ½ in. Type L hard, 5 ft
VENTRAL ½ in. nominal (0.625 in. OD) Type L hard copper pipe, 5 ft
The standard indoor tube in the size most fixtures use
Rated 1,242 psi at 100°F in the hard temper
6.9% more bore area than ½ in. Type K
5 ft fits in a car, unlike a 20 ft stick
Listing names Type L, 0.625 in. OD and hard temper
Cons
Only 5 ft per piece; long runs need couplings
Thinner wall than K for buried work
Sold by a third-party seller, not Amazon.com
½ in. nominal0.625 in. OD0.545 in. ID0.040 in. wall0.285 lb/ft5 ft straight
Buy it if
Your job is ½ in. supply piping indoors, new or repair: the branches that feed sinks, toilets, a water heater or a washer box.
Skip it if
The tube is going in the ground. Use Type K, like the ¾ in. Type K coil, or ask your water utility what it requires.
VENTRAL, a US pipe fabricator, cuts this hard-temper ½ in. Type L tube to 60 in. lengths. The listing puts the outside size at 0.625 in., the true OD of ½ in. nominal copper. VELOCITY/VENTRAL, a third-party seller, had it new and in stock on Oct 21 and again on Oct 22, 2026.
Type L is the everyday supply tube inside a house. It has the same 0.625 in. outside size as Type K at ½ in., so every ½ in. sweat, press and push fitting fits both. The difference is a 0.040 in. wall against K’s 0.049 in.
That thinner wall gives a slightly bigger bore. CDA’s tables put ½ in. Type L at 0.233 sq in. of bore area against 0.218 for Type K. At 3 GPM, CDA’s friction table works out to 6.2 psi lost per 100 ft in Type L and 7.4 in Type K.
In the hard temper, ½ in. Type L is rated 1,242 psi at 100°F. Solder it with 95-5 and the joint, rated 1,090 psi, sets the limit instead of the tube. Braze it and the rating drops to the soft figure, 722 psi, because the heat softens the copper.
Five feet is a handy length. The standard straight length in CDA’s Table 14.1 is 20 ft, which doesn’t fit in most cars. For a repair under one sink or a short reroute, one or two 5 ft pieces usually cover it.
Hard tube carries a colored print along its length, blue for Type L. That print, plus the incised stamp with the type, maker and country, is how you’ll know what’s in your walls years from now.
Cut it square with a tubing cutter and ream the burr out. IPC section 605.13.6 requires cut ends reamed to the full bore for soldered joints, and press-fit makers ask for the same. A burr left inside costs flow and can start erosion at the fitting.
I’ve used this tube on branch lines. My call: for indoor water lines, Type L is the right weight. Type K indoors is extra copper for no gain you’d see at the tap, and Type M’s thinner wall leaves less copper to lose to a pinhole.
Best for patching an existing K service
ICS ¾ in. Type K hard, 5 ft
ICS Industries ¾ in. nominal (⅞ in. OD) Type K hard copper tube, 5 ft
¾ in. nominal0.875 in. OD0.745 in. ID0.065 in. wall0.641 lb/ft5 ft straight
Buy it if
You’re cutting out a damaged section of an existing ¾ in. Type K service, a riser at the meter or a run through a slab, and want the same wall as the rest.
Skip it if
You’re running a whole new service. A 60 ft soft coil puts fewer joints in the ground.
This is a 5 ft straight length of ¾ in. nominal Type K copper in the hard, drawn temper, made by ICS Industries. It was new and in stock from COPPERTUBINGSALES on Oct 21 and once more on Oct 22, 2026. The listing names ASTM B88 and C12200 copper, which CDA says is the copper customarily used for water tube.
It has the same 0.875 in. outside and 0.065 in. wall as the soft coil above. The difference is temper. Hard tube is stiff and straight, and CDA rates ¾ in. Type K hard at 1,466 psi at 100°F, against 852 psi soft.
Five feet is a repair length. The usual job is a leak at the meter or curb stop, a section a shovel or a root found, or a riser coming up through a slab. You cut out the bad section and splice this in with two couplings.
Matching the type matters on a repair. A Type L patch in a Type K line works under pressure, but it’s the thinner spot in the run. If the old line lasted decades in that soil, use the same wall it was built with.
Watch the joint method. If you braze, CDA says to use the annealed rating, because the heat softens the tube near the joint. That’s still 852 psi for ¾ in. Type K, more than five times code’s 160 psi minimum for service pipe.
Service repairs are often in a wet hole. Solder won’t take on a line that’s still dripping. Viega’s ProPress fittings press onto B88 Types K, L and M, and our guide to pressing a wet line covers what press makers allow when the water won’t fully stop.
Hard tube carries a green print for Type K, plus the incised stamp. Cut it with a tubing cutter, not a hacksaw, and ream the inside edge before it goes into a fitting.
I’ve used this tube for patches. My call: keep a short length of K hard on the truck for service repairs. For anything longer than one splice, a soft coil and fewer buried joints is the better job.
Type K and Type L side by side
Figures are for ¾ in. nominal, the smallest water service code allows, from CDA’s 2026 handbook. Scroll sideways on a phone.
Check
Type K
Type L
Ahead
Outside diameter
0.875 in.
0.875 in.
Even
Wall
0.065 in.
0.045 in.
K
Inside diameter
0.745 in.
0.785 in.
L
Bore area
0.436 sq in.
0.484 sq in.
L
Weight per foot
0.641 lb
0.455 lb
L
Rated, hard, 100°F
1,466 psi
1,002 psi
K
Rated, soft or brazed, 100°F
852 psi
582 psi
K
Tested burst, hard
9,300 psi
5,900 psi
K
Friction loss at 5 GPM, per 100 ft
3.5 psi
2.7 psi
L
Printed color on hard tube
Green
Blue
Even
Coils available
60 and 100 ft, ¼ to 1 in.
60 and 100 ft, ¼ to 1 in.
Even
Allowed for buried service under IPC 2024
Yes
Yes
Even
Same fittings
Yes
Yes
Even
“Ahead” means ahead on that one check, not overall. Weight and bore favor Type L; wall and ratings favor Type K. Burst figures are CDA’s averages from three certified tests per size.
How much thicker Type K is, size by size
Same outside size, so the extra wall comes out of the bore. Drawn to scale at ¾ in.
¾ in. Type K and Type L in cross section, to scale. Both are 0.875 in. outside. Source: CDA Copper Tube Handbook (2026), Tables 14.2a and 14.2b.
Size
K wall
L wall
K thicker by
K bore
L bore
K weight
L weight
⅜ in.
0.049 in.
0.035 in.
40%
0.402 in.
0.430 in.
0.269 lb/ft
0.198 lb/ft
½ in.
0.049 in.
0.040 in.
23%
0.527 in.
0.545 in.
0.344 lb/ft
0.285 lb/ft
¾ in.
0.065 in.
0.045 in.
44%
0.745 in.
0.785 in.
0.641 lb/ft
0.455 lb/ft
1 in.
0.065 in.
0.050 in.
30%
0.995 in.
1.025 in.
0.839 lb/ft
0.655 lb/ft
1¼ in.
0.065 in.
0.055 in.
18%
1.245 in.
1.265 in.
1.04 lb/ft
0.884 lb/ft
1½ in.
0.072 in.
0.060 in.
20%
1.481 in.
1.505 in.
1.36 lb/ft
1.14 lb/ft
2 in.
0.083 in.
0.070 in.
19%
1.959 in.
1.985 in.
2.06 lb/ft
1.75 lb/ft
The gap is biggest at ¾ in. and 1 in., the two common water service sizes. At ¾ in., Type K carries 41% more copper per foot than Type L. At ½ in. it’s 21% more.
The bore loss is small in practice. At ¾ in., K’s bore area is 0.436 sq in. against L’s 0.484, about 10% less. That shows up as a little more friction, covered further down.
Pressure ratings for every common size
Rated working pressure at 100°F, from CDA’s Tables 14.3a and 14.3b. Use the soft column for coils and for any hard tube you braze. Scroll sideways on a phone.
Size
K hard
L hard
K soft or brazed
L soft or brazed
½ in.
1,534 psi
1,242 psi
891 psi
722 psi
¾ in.
1,466 psi
1,002 psi
852 psi
582 psi
1 in.
1,126 psi
850 psi
655 psi
494 psi
1¼ in.
914 psi
755 psi
532 psi
439 psi
1½ in.
850 psi
702 psi
494 psi
408 psi
2 in.
747 psi
625 psi
435 psi
364 psi
Ratings drop as the tube gets bigger, because a wider tube puts more force on the same wall. Even 2 in. Type L brazed is rated 364 psi, more than double code’s 160 psi floor for buried service.
Heat lowers them a little. Soft Type L at ¾ in. drops from 582 psi at 100°F to 495 at 150°F. CDA’s hard ratings hold steady to 250°F.
Size
K hard
L hard
K soft
L soft
½ in.
9,840 psi
7,765 psi
4,535 psi
3,885 psi
¾ in.
9,300 psi
5,900 psi
4,200 psi
2,935 psi
1 in.
7,200 psi
5,115 psi
3,415 psi
2,650 psi
Tested burst pressures at room temperature, CDA Table 14.5: the average of three certified tests per type and size, each within 5% of the average. Working ratings are set far below these on purpose.
Joints are often the weaker link
CDA puts it plainly: in soldered systems, “the rated strength of the joint often governs design.” Here are its ratings for ⅛ to 1 in. joints at 100°F.
Joint
Rated at 100°F
Below ¾ in. Type L hard (1,002 psi)?
Notes
95-5 tin-antimony solder
1,090 psi
No
Lead-free; common for water lines
Alloy HB solder
1,035 psi
No
Lead-free
Alloy E solder
710 psi
Yes
Lead-free
50-50 tin-lead solder
200 psi
Yes
Banned on drinking water lines since 1986
Brazed (1100°F and up)
Tube’s soft rating
Yes, 582 psi
Heat anneals the tube
The takeaway for K vs L: if you solder with a common lead-free solder, a Type L line and a Type K line end up rated by their joints, not their walls. The extra wall of K doesn’t make the line any stronger at the fittings.
A smaller bore means a little more friction. CDA’s Table 14.6 gives the loss per foot; here it is per 100 ft at everyday flows.
Pressure lost to friction over 100 ft of straight tube. Source: CDA Copper Tube Handbook (2026), Table 14.6, Hazen-Williams formula with C = 150; we checked each figure against the formula. Flows kept under 5 ft per second, CDA’s recommended range.
At ¾ in. and 5 GPM, 100 ft of Type K loses 3.5 psi and Type L loses 2.7. That’s under 1 psi of difference over a long service line, against the 80 psi code allows inside a house.
The gap grows with flow. Push a ¾ in. line hard and Type K’s smaller bore costs more. If a service run is long and your street pressure is already low, the fix is a bigger size, not a thinner wall. Our low water pressure guide covers the other causes first.
Where code and the copper industry put each type
Since Jan 1, 2026, Georgia’s plumbing code is the 2024 IPC with state amendments. Its rules on copper tube type are short, and looser than most people expect.
Use
IPC 2024 (Georgia) allows
CDA’s minimum recommendation
What we’d use
Buried water service
K, L or M; rated 160 psi or more
M hard in straight lengths, or L soft in coils
K soft coil
Water lines inside the house
K, L or M
M
L hard
Hot water lines
Rated 100 psi at 180°F or more
M
L hard
Hydronic and radiant heat
Not covered by this chapter
L
L
Water service size
¾ in. minimum
Not stated
¾ in. or 1 in.
Code’s own table lists copper tube “Type K, WK, L, WL, M or WM” for both water service and distribution. The real test for buried pipe is section 605.3: a working pressure rating of at least 160 psi at 73.4°F. Every K, L and M size clears that.
CDA says its recommendations are minimums and that codes govern. Your water utility may also set a rule for the line between its meter and your house, so call it before you dig.
So why run K underground at all? Soil, rocks and backfill wear on a wall from the outside, and the line is hard to reach once it’s buried. Extra wall is cheap insurance on the one run you don’t want to dig up twice.
Inside, the tube sits in still air, where the wall rarely wears from outside. There, L’s lighter weight and bigger bore win, and M is cheaper still where code and your water allow. Our Type L vs Type M guide covers that choice.
How to tell Type K from Type L
Outside, they’re the same size. Start with the easiest check at the top.
Check
Type K
Type L
Works on
Printed color stripe
Green
Blue
Hard tube only
Incised stamp
“K”, maker, country
“L”, maker, country
Hard and soft
Bore at ¾ in., with calipers
0.745 in.
0.785 in.
A cut end
Wall at ¾ in., with calipers
0.065 in.
0.045 in.
A cut end
Bore at ½ in., with calipers
0.527 in.
0.545 in.
A cut end
Wall at ½ in., with calipers
0.049 in.
0.040 in.
A cut end
Per CDA’s handbook, every K, L and M tube carries an incised stamp with its type, the maker’s name or mark and the country of origin. Hard tube adds a printed line in its type’s color. Old print wears off and soft coils never had it, so look for the stamp.
No stamp left? Measure a cut end. At ¾ in., Type K’s wall is 0.020 in. thicker than Type L’s, easy to read on cheap digital calipers. Don’t confuse blue-printed ACR refrigeration tube with Type L; ACR is sized by its actual outside diameter.
Two tools for either type
K and L cut and ream the same way. Both tools were new, in stock and sold by Amazon.com on Oct 21 and once more on Oct 22, 2026.
Best for cutting ¼ to 1⅛ in. OD tube in tight spots
The RIDGID 101 is a close-quarters cutter for ¼ to 1⅛ in. outside diameter, which covers ¾ in. nominal at ⅞ in. OD. The 227S reams ½ to 2 in. tube inside and out. I’ve used both. A thicker wall leaves a bigger burr, so ream every cut on Type K.
What is the difference between Type K and Type L copper?
Wall thickness. Both have the same outside diameter and take the same fittings, but Type K’s wall is thicker: 0.065 in. against 0.045 in. at ¾ in. That gives K higher pressure ratings and more metal to wear through, and gives L a bigger bore and less weight.
Is Type K copper the thickest?
Of the common water tube types, yes. Type K is thicker than Type L, which is thicker than Type M. CDA’s handbook states it directly: Type K walls are thicker than Type L, and L thicker than M, at any size.
Is Type K copper expensive?
It costs more than Type L because it uses more copper: about 41% more per foot at ¾ in., by CDA’s weight tables. The buttons above carry Amazon’s live price; no price on this page is typed by hand.
How do you tell if copper is Type K?
Look for a green printed stripe on hard tube, or an incised “K” stamp on any tube. Without markings, measure a cut end. At ¾ in., Type K has a 0.065 in. wall and a 0.745 in. bore.
Can Type L copper be buried underground?
Under the 2024 IPC, yes, as long as it’s rated 160 psi or more, which every size is. CDA’s minimum recommendation for buried service is Type L soft in coils or Type M hard in straight lengths. Your water utility may require Type K, so ask first.
Is Type M copper better than Type L?
No. Type M has a thinner wall than L, so it’s lighter and cheaper but has less metal to lose. Code allows M for water lines, and CDA recommends it as a minimum for distribution. See our Type L vs Type M guide for when it makes sense.
Do Type K and Type L use the same fittings?
Yes. Each nominal size has the same outside diameter in K, L and M, so the same sweat, press and compression fittings fit all three. Viega’s ProPress guide covers B88 Types K, L and M.
What size copper should a water service be?
IPC section 603.1 sets ¾ in. as the smallest water service pipe. Longer runs and bigger houses often need 1 in. Your plumber sizes it from the fixture count and street pressure.
What color is Type K copper?
Hard Type K is printed in green, Type L in blue, Type M in red and DWV in yellow, per CDA’s Table 14.1. Soft coils carry only the incised stamp.
How we compared them
Why trust us
Written by Isaac Daniels, a licensed journeyman plumber in Georgia (license #JP507711), who has used every tube and tool on this page. Wall, bore, weight, pressure and burst figures come from the Copper Development Association’s 2026 Copper Tube Handbook; code from Georgia’s plumbing code; seller and stock from Amazon’s Creators API.
How we compare
Only figures CDA, the IPC, Viega and the Amazon listings publish, read Oct 21, 2026.
The spec score checks wall thickness for the size, CDA’s rated pressure and how many joints the length saves. Size, temper and where the tube is going still decide which one you buy.
Percentages and coil weights are our arithmetic from CDA’s tables.
Every link goes to a listing that was new, in stock and holding the buy box when we checked.
The spec score, check by check
All four tubes get three checks taken from CDA’s 2026 handbook tables and the listed length, averaged to one decimal. Every pick has to reach 7.0.
Read the score as a spec summary, not a buying order. A meter-pit repair still takes the Type K length, and a branch line to a sink still takes ½ in. Type L. Soft coils score lower on pressure because annealing lowers the rating, not because they’re a worse buy for a trench.
Check (weight)
How it’s scored
Wall for its size (⅓)
10 = Type K, the thickest wall CDA lists at each size; 9 = Type L
Rated pressure (⅓)
10 = rated 1,000 psi or higher at 100°F in CDA’s tables; 9 = rated 700 to 999 psi; 8 = rated below 700 psi
Joints saved per run (⅓)
10 = a coil of 50 ft or more, so a run needs no joints; 8 = a 5 ft length
Total
Average of the checks, to one decimal
Pick
Wall for its size
Rated pressure
Joints saved per run
Score
ICS ¾ in. Type K soft, 60 ft
10
9
10
9.7
Mueller ½ in. Type L soft, 100 ft
9
9
10
9.3
VENTRAL ½ in. Type L hard, 5 ft
9
10
8
9.0
ICS ¾ in. Type K hard, 5 ft
10
10
8
9.3
Sources
Copper Development Association, The Copper Tube Handbook, Publication A4015-26/24 (2026): Table 14.1 (types, colors, lengths, coils), Tables 14.2a and 14.2b (Type K and L dimensions and weights), Tables 14.3a and 14.3b (rated working pressures), Table 14.4a (soldered and brazed joint ratings), Table 14.5 (burst pressures), Table 14.6 (friction loss), minimum recommendations by application, freezing tests and identification rules. Read Oct 21, 2026.
International Plumbing Code 2024 (ICC), Chapter 6: sections 603.1, 604.8, 605.3, 605.4 and 605.13.6, and Tables 605.3 and 605.4, read on codes.iccsafe.org, Oct 21, 2026. Georgia DCA, Georgia State Amendments to the IPC (2024 Edition), effective Jan 1, 2026: 605.13.6 revised (flux to NSF 61; ream to full bore kept), Tables 605.3 and 605.4 unchanged.
Viega ProPress installation manual IM-PP and product guide PG-PP: tube types and tempers allowed for ProPress fittings. Read Oct 21, 2026.
Amazon listings for the ICS Industries Type K coil and hard length, Mueller GIDS-12L100, RIDGID 101 and RIDGID 227S (seller, condition, stock, brand and model): read through the Creators API, Oct 21, 2026, 1:10 PM. VENTRAL ½ in. Type L hard: read Oct 21, 2026, 2:12 PM. All six again Oct 22, 2026, 1:41 AM.