Choose Camco 02583 only if your heater approves its 4500W, 240V rating, flange, gasket and clearance. For 5500W, consider Camco 02933 only after confirming the same fit requirements.
If approved: Camco 02583, 4500W at 240V$12.85 at AmazonPrice as of Nov 22, 2026, 9:30 AM EST
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product.
Power comparison, not a product score. The correct wattage follows the heater’s rating plate and approved parts list.
What each replacement is for
Best for approved 4500W low-density fits
Camco 02583: 4500W low watt density element
Product photo: Amazon
Camco 4500W 240V Screw-in Foldback Water Heater Element | Low Watt Density (02583)
Low watt density spreads heat over more sheath area
Foldback screw-in construction
Cons
13-inch minimum tank diameter in Camco’s catalog
Not an approved 5500W substitution by default
Heater-specific parts approval still required
025834500W240VLow watt density13 in. minimum tank diameter
Buy it if
Your heater calls for an approved 4500W, 240V screw-in replacement and its internal dimensions accept this foldback shape.
Skip it if
The heater requires 5500W, a different voltage, a flange mount or a part with different clearance.
Camco 02583 is the 4500W option here for a heater that accepts its low watt density foldback design. The Amazon title identifies 4500W and 240V, and Camco’s catalog lists the same model. That is the starting point for selection. Your heater’s approved parts list still has to agree.
Low watt density describes the heat spread along the element sheath. Camco’s troubleshooting manual explains that more surface area carries the same total wattage. At the same voltage, this part therefore has the heating power of a 4500W element. Its density label does not give it 5500W recovery.
The catalog’s 13-inch figure is minimum tank diameter. It does not mean the element is 13 inches long. On a compact tank, have the replacement checked against the actual internal clearance and the heater maker’s instructions. An outside jacket measurement alone does not establish the space inside the tank.
Choose this part after confirming the original requirement, rather than reading an old element as proof. A previous repair could have used the wrong wattage. Rheem’s replacement bulletin requires the replacement’s wattage, voltage, flange and gasket type to match. A. O. Smith also directs owners to the heater’s data plate.
If the existing heater has started running out of hot water sooner than before, a higher wattage is not the first repair decision. A. O. Smith lists a bad lower element and low supply voltage among possible causes. Have the cause checked before ordering a different element or changing the circuit.
My call: keep this on the shortlist when the approved replacement is 4500W at 240V and the low-density foldback fits. For an already approved 5500W heater, compare the 02933 and 02363 instead. Their wattage is different even though all three are screw-in replacements. A shared mounting style does not settle compatibility.
Best for approved 5500W ultra-low-density fits
Camco 02933: 5500W ultra-low watt density element
Product photo: Amazon
Camco 02932/02933 5500W 240V Screw-In Lime Life Foldback Water Heater Element - Ultra Low Watt Density
No model-specific heater cross-reference established here
029335500W240VUltra-low watt density15 in. minimum tank diameter
Buy it if
Your heater approves a 5500W, 240V element with this mounting, shape and internal clearance.
Skip it if
The heater is rated for a 4500W replacement or the tank cannot accept this foldback. Ask the maker about its approved part.
Camco 02933 is the ultra-low watt density option for an approved 5500W, 240V replacement. Amazon’s title shows 02932/02933, while the maker’s catalog identifies the 02933 element. Confirm the ordered model and packaging before fitting it. The paired listing numbers do not authorize another wattage.
The Lime Life name is separate from the wattage. Camco describes lower watt density as spreading the same power over more surface area. Compared with another 5500W element at rated voltage, this part does not gain extra heating power from its density label. It remains a 5500W choice.
Camco’s catalog specifies a 15-inch minimum tank diameter for this foldback. That is a clearance requirement, not its element length. Compare it with the 02363’s documented 11-inch minimum tank diameter before assuming the two fit the same space. The heater maker must also approve the replacement’s mounting and geometry.
The larger electrical input is useful when the complete heater is designed for it. Rheem’s electrical table lists 22.9 amps for a 5500W element operating at 240V. Its 4500W row lists 18.8 amps. That current difference belongs in an electrician’s assessment if you are proposing a change to the heater.
A 30A breaker does not make the 02933 an approved replacement for a 4500W part. The heater’s wiring and controls remain part of the equipment decision. Camco’s troubleshooting manual tells readers to match replacement voltage and wattage and stay within the nameplate rating. Read that instruction before looking at recovery gains.
My call: compare this with the 02363 only after 5500W is confirmed as the approved rating. The choice between them is then about density and physical fit. If 4500W is what the heater requires, return to a matching 4500W part. A faster calculation does not change the approved replacement specification.
Best for approved 5500W fits; 11-inch minimum tank diameter
Camco 02363: 5500W high watt density element
Product photo: Amazon
Camco 02362/02363 5500W 240V Screw-In Foldback Water Heater Element - High Watt Density
11-inch minimum tank diameter does not prove all other clearances
Still needs the exact heater’s parts approval
023635500W240VHigh watt density11-inch minimum tank diameter
Buy it if
The heater approves this 5500W, 240V foldback and its internal clearance meets the part’s requirements.
Skip it if
The heater needs a different rating, mounting or approved part. Do not choose it solely because its minimum tank diameter is smaller.
Camco 02363 is the high watt density 5500W option. The Amazon title pairs 02362/02363 and describes a 240V screw-in foldback. Camco’s catalog has a 02363 row with the same rated input. Match the ordered model to the documentation and your heater’s parts list before treating it as a fit.
Its useful distinction beside the 02933 is the documented minimum tank diameter. Camco lists an 11-inch minimum tank diameter for the 02363 and a 15-inch minimum for the 02933. If the larger foldback cannot fit, the 02363 may be a candidate. It still needs approval for the actual heater, including its mounting and other internal obstructions.
Both 5500W choices provide the same nominal heating power at 240V. The high-density label means that power is concentrated on less sheath surface than a lower-density design. It does not mean a higher total wattage. The recovery calculation should therefore use 5500W for either, rather than awarding this one a speed advantage.
The 11-inch minimum tank diameter should not be compared directly with a seller’s element-length measurement. Minimum tank diameter and flange-to-tip length answer different questions. Keep those measurements in separate columns when checking a replacement. The outside tank jacket is also different from the internal space available to the heating loop.
If your original heater requires 4500W, this part is outside the ordinary matching-replacement decision. Camco’s manual says to match the replacement’s voltage and wattage. Have a qualified technician identify the right part if the plate cannot be read. An available screw-in hole is not evidence that the heater can accept 5500W.
My call: choose between this and the 02933 on confirmed fit and the maker’s density guidance after settling the 5500W rating. Keep the same safety sequence for either part. The tank must be full and air purged before power returns. A smaller foldback still fails if it is energized without the required water coverage.
4500 and 5500 watts side by side
Figures below assume rated 240V input. Compatibility wins over a faster recovery number.
Camco catalog 72001, pages 6–7. Minimum tank diameter is not element length. All three still need the heater maker’s approval; the table does not establish model-specific compatibility.
How many minutes does 5500W save?
Choose the amount of water actually heated and its temperature rise. These are ideal estimates, not measured tank recovery times.
Water heated
Temperature rise
Calculated energy
4500W
5500W
Minutes saved
20 gal
70°F
3.388 kWh
45.2 min
37.0 min
8.2 min
20 gal
90°F
4.356 kWh
58.1 min
47.5 min
10.6 min
40 gal
70°F
6.776 kWh
90.3 min
73.9 min
16.4 min
40 gal
90°F
8.712 kWh
116.2 min
95.0 min
21.1 min
50 gal
70°F
8.470 kWh
112.9 min
92.4 min
20.5 min
50 gal
90°F
10.890 kWh
145.2 min
118.8 min
26.4 min
Shorter bar means less time. Calculated from Rheem TSB 1306. Constant rated power, no draw and no heat loss are assumed.
For 40 gallons heated through 70°F, 5500W saves about 16.4 ideal minutes. That can matter when comparing two complete heaters that are each designed for their listed wattage. It does not mean replacing a failed 4500W element with a 5500W part is approved.
Temperature rise means outlet temperature minus starting water temperature. A 70°F rise could describe heating from 50°F to 120°F. It is not the thermostat setting by itself. A 90°F rise requires more heat for the same gallons, so both wattages take longer in that row.
The gallon column describes water heated through that full rise. It is not a promise about every gallon in a nominal 40-gallon tank after a shower. Tank stratification, thermostat operation and incoming water change the starting conditions. A complete heater’s published performance is the better comparison for an actual household draw.
We used GPH = watts ÷ (2.42 × temperature rise), from Rheem TSB 1306. Minutes are gallons divided by that rate, multiplied by 60. Energy is power multiplied by time. Each display rounds after calculation; savings use the unrounded times.
5500 ÷ 4500 = 1.222: about 22.2% more power. For the same water volume and temperature rise, 4500 ÷ 5500 = 0.818: about 18.2% less ideal time. The different percentages use different starting quantities.
The chart assumes the element receives its rated voltage throughout heating. A 240V element operating on 208V will not produce its full 240V wattage. Verify the supply and the heater’s voltage rating before using these minutes to judge a slow-recovery problem.
Do not use the six rows as a shower-duration chart. They omit heat loss and water drawn during recovery. They also do not measure how hot and cold water mix at a fixture. Their job is narrower: show the time difference between 4.5 and 5.5 kW for the same defined amount of heat.
Why a 30A breaker does not prove compatibility
The heater, branch circuit and replacement shape all need separate checks. A visible breaker number answers only part of that decision.
Check
What settles it
What does not settle it
Heater approval
Exact model, rating plate and approved replacement instructions
The old element or a seller’s universal-fit claim
Electrical capacity
Electrician’s check against the heater manual and local code
A 30A number on a breaker alone
Physical fit
Mounting, gasket and internal clearance
The fact that both parts screw in
Rheem TSB 1305 lists 18.8A for 4500W and 22.9A for 5500W at 240V. Its single-phase wiring table recommends 25A protection for 4500W and 30A for 5500W, with 10 AWG copper in those rows. The bulletin also requires checking local electrical codes.
Those are maker-table recommendations, not a universal instruction to install a particular breaker or wire. The table references a 75°C copper ampacity basis. Your electrician must check the actual conductors, terminations and heater requirements under the code adopted where the heater is installed.
An existing 4500W heater may already be connected to a 30A circuit. That observation does not settle whether the heater’s controls, internal wiring and approved configuration permit 5500W. Start with the heater maker’s answer, then have any proposed electrical changes assessed. Replacing a breaker does not change the appliance’s rating.
If the breaker trips, stop treating wattage as the repair. Have the fault identified before restoring service or changing equipment. Do not fit a larger breaker to keep a problem circuit running. A licensed electrician handles circuit suitability; a qualified heater technician identifies the approved replacement and checks the heater itself.
For service, Rheem TSB 1310 requires disconnecting power and verifying absence of voltage. If you cannot safely perform that check, leave the covers in place and call a qualified professional. A non-contact tester alone is not proof that conductors are safe to touch.
Does 5500W use more electricity?
It draws more power while energized. Heating the same water through the same rise requires the same ideal heat input.
Same task: 40 gal, 70°F rise
4500W
5500W
Power while the element is on
4.5 kW
5.5 kW
Ideal run time
90.3 min
73.9 min
Calculated heating energy
6.776 kWh
6.776 kWh
Prediction of your bill?
No
No
The 5500W element uses 1 kW more power while it is on, but finishes the ideal task sooner. In the 40-gallon, 70°F example, both require 6.776 kWh of calculated heating energy. That follows from the same water volume and temperature rise, rather than a claim that both complete heaters have identical efficiency.
A household bill includes conditions the table leaves out. Tank heat loss, incoming temperature, hot-water use and controls affect real energy consumption. A wattage label alone does not establish an annual bill or an energy saving. Compare complete heaters using their published energy information and the same household assumptions.
My call: choose 5500W in a new heater for a justified recovery requirement, after confirming the electrical installation can support that model. Do not buy it on a promise of lower electricity use. For an element repair, match the approved replacement rating and address the failed component.
Why two elements do not double the wattage
Rheem TSB 1315 describes a non-simultaneous arrangement. It is an operating sequence, not a wiring conversion to perform.
Cold-tank stage
Upper element
Lower element
Upper section needs heat
On under upper thermostat control
Off
Upper section reaches its setting
Off
Control passes to lower thermostat
Lower section needs heat
Off
On under lower thermostat control
Both sections satisfied
Off
Off
In this non-simultaneous configuration, the upper thermostat gives the upper element priority on a cold tank. When the upper section reaches its setting, control transfers to the lower thermostat. Rheem says only one element heats at a time in the arrangement it describes.
Two 4500W elements therefore do not automatically mean a 9000W running load. The wiring configuration decides whether the elements can run together. A heater specifically configured for simultaneous operation needs its own instructions and electrical assessment. Do not carry the non-simultaneous assumption across every heater model.
A lower-element failure can reduce available hot water even when the upper element still works. A. O. Smith lists a bad lower heating element as a cause of insufficient hot water. That is a reason to diagnose a changed symptom before deciding the original 4500W specification was too small.
Upper and lower wattages must each follow the exact heater’s approved configuration. Do not mix 4500W and 5500W merely because they take turns. Have a technician use the model’s rating information, wiring diagram and parts list when the two installed elements do not match or the repair history is unknown.
Watt density is a separate choice
Settle voltage and approved wattage first. Then compare how the element spreads that power over its surface.
Choice
Total rated heat
What changes
4500W low density
4500W at rated voltage
Heat per unit of sheath area
5500W ultra-low density
5500W at rated voltage
Heat distribution and physical shape
5500W high density
5500W at rated voltage
Heat concentration and physical shape
Camco’s troubleshooting manual explains watt density as the concentration of heat at the element surface. A lower-density element has more surface area for a given wattage. Its total rated power stays the same. Compare two approved 5500W parts on fit and density, rather than treating one density label as faster recovery.
The 02583 and 02933 are not a clean test of density alone because their wattages differ. The 02583 is 4500W low density; the 02933 is 5500W ultra-low density. The 02363 and 02933 share 5500W, so their density and clearance differences are easier to separate from total input.
Camco discusses lower-density elements for water with high lime content, but that does not establish a service-life promise for your heater. Water conditions and maintenance still matter. A density label does not prove an element will last a certain number of years or avoid every mineral deposit.
Do not let dry-fire resistance claims change the refill sequence. A. O. Smith requires a completely full tank and an air purge before restoring power. Follow the exact heater manual after any replacement. If you cannot confirm the tank is full, keep the electricity off and have the installation checked.
Check voltage and physical fit before ordering
Photograph the accessible rating plate and record the model before shopping. Leave electrical covers closed unless you are qualified to service the heater.
Read or check
Why it matters
Take this to the supplier or technician
Heater model and serial
Identifies the correct parts information
Clear plate photograph
Voltage and wattage for each position
Defines approved electrical input
Upper and lower ratings, if different
Mounting and gasket type
Determines how the element seals
Exact approved part reference
Minimum internal clearance
Prevents a foldback from contacting obstructions
Heater maker’s replacement guidance
Rheem TSB 1310 requires the flange, gasket type, wattage and voltage to match. A screw-in element and a four-bolt flange are different mounts. Even when two parts share a mount, the tank must accommodate the replacement’s shape. A part that starts threading into an opening is not a completed compatibility check.
A. O. Smith’s care guide says to use the data plate for the correct voltage and wattage. If the label is unreadable, ask the heater maker or a qualified technician to identify the approved replacement from the model and serial number. Do not choose a part from tank capacity alone.
Supply voltage changes the result too. Rheem TSB 1317 lists a 4500W/240V element at 3380W on 208V, and a 5500W/240V element at 4130W on 208V. Those are its published dual-rating figures. They should not be read as a general authorization to run any heater on either voltage.
The reverse voltage substitution needs particular care: a part designed for a lower voltage can exceed its intended output on a higher supply. Have an electrician confirm the actual supply when it is uncertain. Our 240V vs 208V element guide explains the voltage question separately.
Where documents differ
What is printed
How to use it
Camco 02933 and 02363 at 208V versus Rheem 5500W figures
Documents give different values; the reason is not established. Use the exact heater and part documentation
Camco 02583 at 208V versus Rheem 4500W figure
Camco catalog: 3500W; Rheem 1317: 3380W
Use Camco’s part-specific documentation for 02583; do not silently substitute a generic value
Camco catalog diameter versus a seller length
13, 15 and 11 inches are minimum tank diameters
Do not relabel them as flange-to-tip lengths
Paired Amazon titles
02932/02933 and 02362/02363
Confirm the actual 02933 or 02363 ordered; no conflicting wattage is shown
No wattage or density disagreement was found between the Amazon listing titles and the Camco catalog entries used here. Confirm the exact heater model’s approved parts list and internal clearance before ordering.
When each wattage is the right choice
Approved replacement is 4500W
Keep 4500W and match voltage, mount, gasket and clearance. Compare the 02583 only if your heater maker approves that replacement.
Approved replacement is 5500W
Compare the 02933 and 02363 on density and the documented 15-inch versus 11-inch minimum tank diameter. Confirm all other fit requirements.
Buying a complete heater
Compare the exact heaters’ recovery and household capacity. A 5500W model can justify its faster input when the installation supports it.
Plate or repair history is unclear
Use the model and serial number to obtain the maker’s approved replacement information. Do not assume the installed element was correct.
Trip, burned wiring or a recall match
Stop using affected equipment and have the fault or recall remedy addressed. A larger element or breaker does not repair the cause.
If a previously satisfactory 4500W heater now runs short, start with diagnosis. The lower element, thermostat and supply voltage are checks in A. O. Smith’s troubleshooting guidance. A matching repair may restore the original performance. It should not be sold as a reason to change the heater’s wattage.
If the original heater has never met the household’s hot-water demand, compare complete replacement models. The minutes-saved chart shows one part of that decision. It does not account for the heater’s stored usable hot water or the timing of several draws. Keep capacity and recovery as separate questions.
For a technician’s visit, bring the model and serial photograph, the symptom and when it changed. Ask for the approved replacement part number and whether the circuit matches that heater. That produces a checkable decision rather than a guess based on the breaker handle or a seller’s broad compatibility list.
What safe replacement involves
This is a planning sequence for qualified service. Use the exact heater manual for the work, and call a qualified person if electrical isolation or draining is uncertain.
1
Disconnect and prove power is off
Rheem 1310 requires disconnecting electrical power and checking for absence of voltage before service. A qualified person uses an appropriate meter and safe verification procedure. Keep others from restoring the supply.
2
Cool and drain as the manual requires
A. O. Smith’s care guide calls for running hot water until it is cool before draining. Route the discharge safely and follow its water shutoff sequence. Hot water can scald; do not open an element on a hot, pressurized tank.
3
Confirm and fit the approved replacement
Match voltage, wattage, mounting and gasket. Rheem 1310 says to drain below the element being replaced. Use the heater’s actual instructions for draining, seals and tightening; do not borrow a torque or sealant rule from another model.
4
Refill and purge before restoring power
A. O. Smith 100341465 calls for the drain closed, cold supply open and a hot faucet flowing fully for at least three minutes. That is its procedure; follow your own heater manual. Check for leaks while power remains off.
5
Restore wiring and protective covers
After a leak-free fill, the A. O. Smith guide restores element wires, protective cover, insulation, access panel and junction-box cover before power. Keep power off if a leak persists or the safe condition cannot be confirmed.
A dry element can be damaged when electricity returns before water covers it. The refill step belongs before energizing, even if the replacement has a dry-fire resistance claim. Do not use a short power-on check to find out whether the repair works while the tank is still filling.
CPSC domain searches found no matching element recall; not an exhaustive clearance
Check the exact brand and model again before repair
Certain Rheem Performance Platinum electric heaters
CPSC recall 16-177 concerns an overheating control panel
Compare exact model and serial with the official notice; stop use and request the remedy if affected
The Rheem recall is about specified heaters, not every replacement element or every Rheem electric tank. CPSC identifies affected Performance Platinum units by model and serial conditions. Check the official notice if your heater may match. An element replacement does not remedy an affected control panel.
Searches for the three Camco models found no matching CPSC element notice in the results inspected. That is a dated search result, not a guarantee that every listing or heater is free of a recall. The exact heater’s model and serial remain part of the service check.
Questions people ask
Can I replace a 4500-watt element with a 5500-watt element?
Only if the exact heater’s approved configuration permits that part and a qualified electrician confirms the installation. Camco tells readers to match voltage and wattage and never exceed the nameplate. A 30A breaker or matching screw thread alone does not authorize an increase.
Can I replace a 5500-watt element with a 4500-watt element?
Do not assume lower wattage is automatically an approved replacement. Rheem 1310 calls for matching wattage and voltage as well as mounting and gasket. Get the maker’s approval for any alternate configuration. If approved, 4500W heats the same ideal task more slowly than 5500W.
How much faster does a 5500-watt element heat water?
At rated input, it has 22.2% more power and takes about 18.2% less ideal time for the same water volume and temperature rise. Heating 40 gallons through 70°F calculates to 90.3 minutes at 4500W and 73.9 at 5500W. Actual tank recovery depends on operating conditions.
Does a 5500-watt water heater use more electricity?
It draws more power while the element is energized. For the same water volume and temperature rise, the ideal heat input is the same and the 5500W element runs for less time. Wattage alone cannot predict annual electricity use or compare complete-heater efficiency.
How many amps do 4500W and 5500W elements draw?
At 240V, Rheem 1305 lists 18.8A for 4500W and 22.9A for 5500W. These figures apply to those wattages at that voltage. A 240V-rated element on 208V produces less power and draws a different current.
Can both wattages use a 30-amp circuit?
The actual heater manual and local electrical requirements decide. Rheem 1305 recommends 25A protection for 4500W and 30A for 5500W at 240V in its single-phase table. An existing 30A circuit does not authorize changing a 4500W heater to 5500W. Have an electrician assess it.
Do both water heater elements run at once?
In the non-simultaneous arrangement described by Rheem 1315, only one heats at a time. The upper thermostat first heats the upper section and then transfers control to the lower thermostat. Heaters specifically configured for simultaneous operation require their own wiring and electrical checks.
Can the upper and lower elements have different wattages?
Use the exact heater’s approved upper and lower specifications. Do not mix ratings solely because the elements operate in sequence. If the installed parts disagree or the repair history is unknown, have a qualified technician check the rating information, wiring diagram and approved parts list.
Does low watt density mean slower heating?
No. At the same rated wattage and voltage, lower density distributes the same total power over more surface area. A 5500W ultra-low-density element and a 5500W high-density element therefore have the same nominal power. Density, shape and heater approval still affect which part to choose.
Will a 5500-watt element produce 5500 watts on 208V?
A 5500W element rated at 240V produces less on 208V. Rheem 1317 lists 4130W for its dual-rated example; its formula bulletin gives about 4131W. An element specifically rated 5500W at 208V is different. Confirm both the supply and the heater’s approved rating.
How we pick and why trust us
Why trust PlumbingPicks
Isaac Daniels, licensed journeyman plumber in Georgia, is the named author. We read the heater makers’ replacement and electrical guidance, compared it with Camco’s model information and checked the Amazon offer records. The advice centers on approved fit and safe service.
How we pick
We compare documented voltage, wattage, density and clearance. These are research-based part selections, not measured field recovery results. Wattage and voltage aren’t in the spec score, because the heater’s rating plate sets them; the score only compares elements that already match it.
The heating-time table is calculated from Rheem 1306. It assumes constant rated input, no heat loss and no water draw. Amazon offers were read October 20, 2026 and again October 22, 2026, 2:33 AM EDT: the 02583 and 02933 from Amazon.com, the 02363 from American Tool Supply, all new and in stock. Live availability can change. Displayed prices rely on the site’s current Amazon data feed.
The spec score, check by check
The three Camco elements get the same three checks, read from Camco’s catalog and its Amazon listings on Oct 22, 2026, then averaged to one decimal. Every pick has to reach 7.0.
Wattage isn’t in the score. Your heater’s rating plate decides between 4500W and 5500W first; the score only compares elements that already match it. The 02363 scores lowest for its high watt density, yet it’s the one that fits an 11 in. tank.
Check (weight)
How it’s scored
Watt density (⅓)
10 = ultra-low (ULWD); 9 = low (LWD); 6 = high (HWD). lower density spreads the heat over more sheath, and Camco says it reduces lime buildup in hard water
Smallest tank it fits (⅓)
10 = an 11 in. minimum tank diameter; 9 = 13 in.; 8 = 15 in. (Camco’s catalog and listings)
Seller (⅓)
10 = sold by Amazon.com; 8 = sold by a third-party seller
Total
Average of the checks, to one decimal
Pick
Watt density
Smallest tank it fits
Seller
Score
Camco 02583, 4500W LWD
9
9
10
9.3
Camco 02933, 5500W ULWD
10
8
10
9.3
Camco 02363, 5500W HWD
6
10
8
8.0
Check
Selection rule
Limit
Approved input
Match exact heater guidance and rating
No blanket wattage substitutions
Physical fit
Match mount, seal and clearance
Minimum tank diameter alone is incomplete
Seller offer
Genuine named model, New, in stock
Low-stock 02923 excluded
Recovery estimate
Rheem 1306 formula, same volume and rise
Not a first-hour or field test
Scoring
No product scores
Compatibility cannot be averaged into a score
Sources
Rheem Technical Service Bulletin 1305, Heating Element Properties: electrical and recovery tables, page 1; single-phase breaker and copper-wire recommendations, page 2. Read October 20, 2026.
Rheem Technical Service Bulletin 1306, Statement of down-rating electrical heating elements, page 1: voltage and recovery formulas. Read October 20, 2026.
Rheem Technical Service Bulletin 1310, How to Replace an Electrical Heating Element, page 1: matching requirements, disconnection, voltage verification, draining and refill. Read October 20, 2026.
Rheem Technical Service Bulletin 1315, Non Simultaneous Operation, Double Element Water Heaters, page 1. Read October 20, 2026.
Rheem Technical Service Bulletin 1317, Dual Voltage Rating on Residential Electric Water Heaters, page 1. Read October 20, 2026.
A. O. Smith Residential Electric Water Heater Use and Care Guide 100341465: troubleshooting; element replacement, pages 21–22. A. O. Smith service handbook 321547-000, page 22: verify no power with an AC voltmeter. Klein NCVT3P instructions: no indication does not establish absence of voltage. Read October 20, 2026.
Camco Plumbing and Hardware catalog 72001, 2021, pages 6–7: 02583, 02933 and 02363 ratings, density and minimum tank diameter. Ratings and minimum tank diameters vary by model; match the heater’s approved parts list.
Camco Water Heater Troubleshooting Manual 70040: Choosing the Correct Heating Element, printed page 4; higher-wattage replacement question, printed page 14. Read October 20, 2026.
Amazon offer reads October 20, 2026, approximately 11:42 EDT; search read 11:50 EDT. Exact titles, ASINs, condition and stock. Product image URLs for all three elements read October 20, 2026, at 12:40 EDT. Offers and listing text re-read October 22, 2026, 2:33 AM EDT.
CPSC recall database searches for Camco water heater elements and models 02583, 02933 and 02363, October 20, 2026. CPSC recall 16-177, May 26, 2016, Rheem Performance Platinum water heaters.