Details ↓What an AAV can replace, and the vent it can’t.
As an Amazon Associate I earn from qualifying purchases.
An air admittance valve (AAV) lets air in but never out. It can replace a sink or bathroom vent, but code still wants one open vent to the outdoors (IPC 918.7). Match the valve to the pipe and fixture load first.
Only the Oatey Sure-Vent is linked; the Studor parts are reference notes. Ratings come from the makers’ own sheets, not the listings. The wall box for an in-wall valve has its own section further down.
Reference (not linked)
Details ↓
Reference (not linked)
Details ↓Reference (not linked)
Details ↓Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product.
Both let air into the drain when water pulls a vacuum. Only the open pipe lets pressure back out.
Water running down a drain drags air with it. If no air can get in behind it, the drain pulls water out of the nearest trap, and an empty trap lets sewer gas into the room. A vent is the air supply that stops that.
An open vent pipe and an AAV both handle that suction. Studor’s manual says its membrane lifts on even a small vacuum and drops shut by gravity once the pressure evens out. There are no springs in it.
Pressure is the other half. Pressure from the sewer or a septic tank pushing back up the pipe needs a way out. An open vent lets it go over the roof. An AAV can’t: Studor says pressure makes it seal even tighter, and Oatey says its valves aren’t designed to relieve it.
That’s why IPC 918.7 keeps at least one stack vent or vent stack open to the outdoors in every plumbing system. Studor goes a step further: one open vent for every building drainage system, so a building with two sewer tie-ins needs two.
Studor 20341 Mini-Vent air admittance valve, 1½ to 2 in., PVC adapter
Reference (not linked): This one isn’t linked. The details here are for reference only.
The 20341 is Studor’s Mini-Vent with a PVC adapter, made by IPS Corporation in Collierville, Tennessee. The listing title gives the model, the 1½ to 2 in. connection and the 160 DFU rating.
Studor rates it at 160 drainage fixture units (DFU) on a horizontal branch and 24 DFU on a stack. A DFU is code’s measure of how much a fixture drains: 1 for a bathroom sink, 2 for a tub and 3 for a 1.6 gpf toilet, from IPC Table 709.1.
The drain size caps the load before the valve does. Studor’s branch table limits a Mini-Vent to 3 DFU on a 1½ in. branch, 6 on 2 in., 20 on 3 in. and 160 on 4 in. On most house jobs, the pipe is the real limit, not the 160 on the label.
Inside is a silicone membrane on an ABS body. Studor’s manual says it lifts on a small vacuum, drops back by gravity and seals tighter when the pipe pushes back. That last part is why one open vent per building still has to carry pressure out.
It’s certified to ASSE 1051 for branch use and ASSE 1050 for stacks, and Studor lists ICC-ES report PMG-1025. Studor rates it for −40 to 150°F, with screens inside and outside to keep insects off the membrane.
Studor’s thread rule is strict. Its spec sheet says primer, solvent cement or pipe dope on the threads voids the warranty, so use tape. The install sheet says to hand-tighten only, fit it after the drain test and stand it within 15° of plumb.
The warranty is the long one. Studor’s manual calls it a limited lifetime, meaning the life of the drainage system it’s fitted to, and it covers shipping on the replacement. Labor isn’t covered.
Air admittance valve, 1½ to 2 in., PVC Sch. 40 adapter

Prices and availability are accurate as of the time shown and may change.
Your parts list is all Oatey, or you want the choice of tape or pipe joint compound, for a sink or bath branch on one floor.
You want the longer warranty. The Studor Mini-Vent has the same rating and covers the life of the drainage system.
The 39016 is Oatey’s Sure-Vent for 1½ to 2 in. pipe, with a PVC Schedule 40 adapter. Oatey is a Cleveland maker of drain and vent supplies. The linked listing is a single valve; a 2-pack is a separate option on the listing.
Oatey’s submittal sheet LCS1501c rates this family at 160 DFU on a branch and 24 on a stack, the same as the Studor Mini-Vent. The stepped adapter takes 1½ or 2 in. vent pipe. Oatey lists ASSE 1050 and 1051, ICC ESR-1664 and NSF 14.
The Amazon listing gets the rating wrong. Its bullets say it’s rated 20 DFU and fits vent pipe up to 3 in. Oatey’s own product page and submittal say 160 branch and 24 stack on 1½ to 2 in. pipe. Go by Oatey; 20 DFU is the rating of its smaller 1½ in. valves.
Oatey publishes more about how its valve opens than Studor does. The submittal says its Sweet Spot membrane opens at −0.01 psi and seals at 0 psi and above, and that every valve is tested at ¼ in. and 30 in. of water column.
Its install rules match the 2024 IPC: fixtures on the same floor, a horizontal branch, at least 4 in. above that branch, 6 in. above insulation and within 15° of vertical. Oatey also says the branch must join the stack within four branch intervals of the top.
On threads, Oatey is looser than Studor. Its sheet says to use approved pipe joint compound or thread seal tape. Tape is the safe habit for both brands, so a later swap to a Studor valve doesn’t void anything.
The warranty is the weak spot. Oatey’s limited warranty runs one year from the date of sale, and a claim has to be in writing within 30 days of finding the problem or 13 months from the sale, whichever comes first. Sure-Vent isn’t on Oatey’s list of longer-warranty products.
My call: it does the same job as the Mini-Vent on a sink or bath branch. Pick it when an all-Oatey parts list or the choice of tape or compound matters more to you than the warranty.
Studor 20391 AAV Tee with Redi-Vent, 1½ in. tubular connection
Reference (not linked): This one isn’t linked. The details here are for reference only.
The 20391 is a Studor Redi-Vent valve on a polypropylene tee for 1½ in. tubular drains, the slip-nut kind under most sinks. IPS sells the tee alone as part 40800. This one is the valve and tee together.
Studor’s sheet says it vents up to 20 DFU on a horizontal branch. Its branch caps match the Redi-Vent’s: 3 DFU on 1½ in., 6 on 2 in. and 20 on 3 or 4 in. A kitchen sink is 2 DFU in IPC Table 709.1, even with a disposer and dishwasher, so one sink fits with room to spare.
Studor’s sheet still wants the valve at least 4 in. above the horizontal branch or fixture drain it vents, the same as IPC 918.4. In a shallow cabinet or under a low vanity, measure that height before you buy.
The cabinet is a fine home for it. Studor’s manual says locating the valve in a sink or vanity cabinet is acceptable, because the cabinet lets air reach it and you can get to it. Don’t wall it in behind a false back.
It has the same membrane and the same rules as the Mini-Vent: no springs, shut by gravity, tighter under pressure. Fit it after the drain test, upright within 15° of plumb, with tape and no pipe dope on the threads.
Studor’s sheet calls this valve an alternative to running a vent through the roof or a side wall, for individual, common, circuit, loop and island fixture vents. The warranty is Studor’s limited lifetime, and it’s rated from −40 to 150°F.
It fits best on a sink with no vent pipe nearby: an island, a basement bar sink, or a remodel that moved the sink away from the wall. Where your code allows an AAV there, this is the least new pipe you can add.
Studor 20302 Maxi-Vent air admittance valve, 3 or 4 in.
Reference (not linked): This one isn’t linked. The details here are for reference only.
The 20302 is Studor’s Maxi-Vent for 3 and 4 in. pipe. The Amazon listing sits in the Studor store, and its photo shows the Studor Maxi-Vent and IPS Corporation label.
The listing’s back-end details are messy. They name the maker as Alfi and the model as GIDDS-301050, and one bullet types ASSE 1050 as 10510. The title, the store and the label on the valve all say Studor 20302, so check the label when the box arrives.
It’s a stack-type valve. Studor’s manual rates it at 500 DFU on a 4 in. stack and 72 DFU on a 3 in. stack. On a horizontal branch, it’s 20 DFU on 3 in. and 160 on 4 in., the same caps as the Mini-Vent.
Code puts two limits on any stack valve. IPC 918.3.2 bars it from a stack with more than six branch intervals, and 918.4 puts it at least 6 in. above the flood level rim of the highest fixture it serves. Studor’s own rules say the same.
The joint is simple. On 4 in. pipe, the valve’s rubber gasket pushes onto the pipe. On 3 in. pipe, you take the connector off and use a no-hub coupling. Studor’s install sheet says not to solvent-cement the Maxi-Vent to the pipe.
The one rule it can’t beat is IPC 918.7: every plumbing system keeps at least one stack vent or vent stack open to the outdoors. So the Maxi-Vent caps a second stack, and the main stack still goes through the roof.
Fit it after the drain test, cut the pipe square and stand the valve within 15° of plumb, with air around it and a way to reach it. In an attic, keep it at least 6 in. above the insulation.
| Studor 20380 | What Studor and the listing say |
|---|---|
| Size | 6⅝ in. wide, 8 in. high |
| Pipe | 1½ or 2 in. ABS or PVC |
| In the box | Box, mounting flange, snap-on grille and a gasketed test cap |
| Valve | Sold separately: Mini-Vent, Tec-Vent or Redi-Vent, per the listing |
| Listings | UPC and ICC, per Studor |
| Fits | The vent riser lands inside a finished wall, such as behind a pedestal sink or in a laundry wall, and the valve has to stay reachable with air around it. |
| Not needed | The valve sits in an open sink cabinet. Studor says a cabinet already counts, so the AAV Tee or Mini-Vent can go there with no box. |
The 20380 is Studor’s recessed box and grille, the part that lets an AAV sit inside a wall and still meet code. The valve isn’t included; the listing names the Mini-Vent, Tec-Vent and Redi-Vent as the valves it takes.
Code is the reason it exists. IPC 918.5 says every AAV needs access and a spot where air can get in. A valve sealed behind drywall fails both. Studor’s manual says to use its recess box and grille for any in-wall installation.
The box and its mounting flange are one piece, so Studor says no extra framing is needed in the stud bay. It connects to 1½ or 2 in. ABS or PVC vent pipe.
A test cap with a rubber gasket is built in. That matters because IPC 918.2 says AAVs go in after the drain, waste and vent test. You test with the cap in place, then thread the valve on at finish.
| Where the box does well | What to watch |
|---|---|
| One-piece box and flange; no extra framing | Box only; the valve is sold separately |
| Built-in test cap with gasket for the drain test | Takes Studor’s small valves only, per the listing |
| Snap-on grille lets air in and keeps access | The grille shows on the finished wall |
| Takes 1½ or 2 in. ABS or PVC | Doesn’t change the 4 in. height rule |
The grille snaps on over the opening, and it’s what lets air reach the valve. Don’t paint it shut or hang a mirror over it. If air can’t get in, the valve can’t open.
Height still counts. Set the box so the valve sits at least 4 in. above the branch or fixture drain it vents, under IPC 918.4. A box mounted below the sink’s drain line puts the valve too low.
Studor lists UPC and ICC listings for the box itself. The valve inside carries the DFU rating and the warranty, so choose the valve by its rating first, then use this box to hide it.
When a remodel puts a sink on a wall with no cabinet, the box keeps the AAV reachable and out of sight. Plan the stud bay for it before the drywall goes up.
Reference (not linked): this box isn’t linked here. A box isn’t a valve, so it isn’t compared with the four above.
Code sections are from the 2024 IPC, Georgia’s plumbing code since Jan 1, 2026. Scroll sideways on a phone.
| Check | Air admittance valve | Open vent pipe |
|---|---|---|
| Lets air in on suction | Yes | Yes |
| Lets pressure out | No, seals tighter | Yes |
| Goes through the roof or a wall | No | Yes, with flashing |
| Can be the building’s only vent | No (918.7) | Yes |
| Moving parts | One membrane | None |
| Must stay reachable | Yes (918.5) | No |
| Fitted before or after the drain test | After (918.2) | Part of the test |
| Clearance from windows and air intakes | Can’t be used just to cut it (918.8) | 10 ft sideways or 3 ft above (903.5) |
| Cold-climate rule | −40 to 150°F per Studor | 3 in. minimum through the roof where design temperature is 0°F or below (903.2) |
| Warranty | Studor: life of the system; Oatey: 1 year | Pipe and fittings, by maker |
Neither is better at everything. The open vent wins on pressure and has nothing to wear out. The AAV wins where a new roof penetration or a long vent run is the hard part.
Ratings from Studor’s and Oatey’s own sheets. Scroll sideways on a phone.
| Part | Job | Pipe | Branch rating | Stack rating | Thread sealant | Warranty |
|---|---|---|---|---|---|---|
| Studor Mini-Vent 20341 | Sinks, bathrooms, laundry | 1½ or 2 in. | 160 DFU | 24 DFU | Tape only | Life of the system |
| Oatey Sure-Vent 39016 | Sinks, bathrooms | 1½ or 2 in. | 160 DFU | 24 DFU | Tape or compound | 1 year |
| Studor AAV Tee 20391 | Tubular sink drains | 1½ in. tubular | 20 DFU | n/a (branch only) | Tape only | Life of the system |
| Studor Maxi-Vent 20302 | Second stack | 3 or 4 in. | 160 DFU (4 in.) | 500 DFU (4 in.) | None; gasket or coupling | Life of the system |
| Studor 20380 box | Valve inside a wall | 1½ or 2 in. | Valve’s | n/a | n/a | n/a |
Every height and position rule from code and both makers, in one drawing.
| Rule | IPC 2024 | IRC 2024 | Studor | Oatey |
|---|---|---|---|---|
| 4 in. above the branch or fixture drain | 918.4 | P3114.4 | Yes | Yes |
| Stack valve 6 in. above the highest flood rim | 918.4 | P3114.4 | Yes | Not in its sheet |
| 6 in. above insulation | 918.4, anywhere | P3114.4, attics | Yes, attics | Yes |
| Upright, within 15° of plumb | Not stated | Not stated | Yes | Yes |
| Reachable, with air getting in | 918.5 | P3114.5 | Yes | Not in its sheet |
| Fitted after the drain test | 918.2 | P3114.2 | Yes | Not in its sheet |
| Same floor, horizontal branch | 918.3.1 | P3114.3 | Yes | Yes |
| Thread sealant | Not stated | Not stated | Tape only | Tape or compound |
The 4 in. and 6 in. figures are minimums in both the IPC and IRC. Higher is fine, as long as the valve stays reachable and the vent stays within its length limit.
The 15° rule is the makers’, not code’s. Studor’s membrane closes by gravity, so both Studor and Oatey want the valve close to plumb.
“Within the maximum developed length permitted for the vent” is the line people skip in 918.4. An AAV ends a vent; it doesn’t stretch one. The vent pipe from the trap to the valve still has to meet the same length limits as any other vent, which our trap arm length guide lays out by pipe size.
Add the fixture units on the branch from IPC Table 709.1, then check the cap for that pipe size. Scroll sideways on a phone.
| Job on one branch | Fixture units | Branch size | Studor cap at that size | Valve that covers it |
|---|---|---|---|---|
| Bathroom sink | 1 | 1½ in. | 3 | Mini-Vent, Sure-Vent or AAV Tee |
| Kitchen sink with disposer and dishwasher | 2 | 1½ in. | 3 | Mini-Vent, Sure-Vent or AAV Tee |
| Sink and 5.7 gpm shower | 1 + 2 = 3 | 1½ in. | 3, at the limit | Mini-Vent or Sure-Vent |
| Washing machine | 2 | 3 in. drain, 2 in. standpipe | 20 | Mini-Vent (Studor’s washer rule) |
| Full bath: toilet, sink, tub | 3 + 1 + 2 = 6 | 3 in. | 20 | Mini-Vent or Sure-Vent |
| Two full baths back to back | 12 | 3 in. | 20 | Mini-Vent or Sure-Vent |
| Two baths, kitchen and laundry | 16 | 3 in. | 20 | Mini-Vent or Sure-Vent |
| Same, on a 4 in. branch | 16 | 4 in. | 160 | Mini-Vent or Sure-Vent |
| Second stack in a two-story house | Stack load | 3 or 4 in. stack | 72 or 500 | Maxi-Vent |
Fixture units are IPC 2024 Table 709.1: lavatory 1, kitchen sink 2, shower up to 5.7 gpm 2, bathtub 2, residential washer 2, 1.6 gpf toilet 3. Branch caps are Studor’s tables for the Mini-Vent; Oatey’s submittal doesn’t give caps by branch size. Your drain must also be sized to code on its own.
The pattern is clear in the table. On a 1½ in. branch, the 3 DFU cap fills up fast, so a sink and a shower on one small branch is as far as it goes. On a 3 in. branch, one Mini-Vent covers a couple of bathrooms.
Washers get their own rule. Studor’s install sheet says that when a Mini-Vent vents a washing machine, the standpipe must be at least 2 in. and the horizontal drain at least 3 in. Our washing machine standpipe guide covers the standpipe height rules.
Which code you’re under depends on your state and city. Georgia uses the 2024 IPC with state amendments, and those amendments don’t touch section 918.
| Code | Where it’s used | AAVs | Key sections |
|---|---|---|---|
| IPC 2024 | Georgia since Jan 1, 2026, and other places that adopt it | Allowed, with limits | 918.1 to 918.8 |
| IRC 2024 | Houses where the IRC plumbing chapters are adopted; Georgia leaves them out | Allowed, with limits | P3114.1 to P3114.8 |
| UPC 2024 | Places that adopt the Uniform Plumbing Code | No section on them | Studor cites 301.2, alternate materials and methods |
The IPC and IRC rules are nearly the same: branch and individual valves to ASSE 1051, stack valves to ASSE 1050, same-floor fixtures only, 4 in. and 6 in. heights, access, and one open vent per system.
The IPC adds a ban in plenums and chemical waste systems, a relief vent for branches more than four intervals down, and the six-interval limit on stack valves.
The 2024 UPC is different. I searched IAPMO’s free 2024 UPC text for “air admittance” and got no hits, so it has no section on them at all. Studor lists UPC section 301.2, the alternate materials and methods route, which means your building department decides case by case.
Whatever the book says, your local inspector has the last word, and a city can amend its code. Call before you buy.
From IPC 2024 section 918 and the makers’ sheets. Any one of these rules out a valve.
IPC 918.7: at least one stack vent or vent stack goes outdoors in every system.
IPC 918.8. Studor and Oatey sheets agree.
Not on nonneutralized special waste unless the valve meets ASSE 1049 and the other 918.8 tests.
Only where an engineer designed the vent system (918.8). Oatey and Studor also want local approval first.
918.8 bars an AAV on an outdoor vent terminal just to get closer to an air intake.
918.3.2 for stack valves. Branch valves more than four intervals down need a relief vent (918.3.1).
918.3.1: branch valves vent only same-floor fixtures on a horizontal branch.
918.5 needs access and air. Use a recess box and grille.
Sewage pits come up often. As a sealed ejector pit fills, the rising water pushes air out of it, and that’s pressure an AAV can’t release. Code allows a valve there only with an engineered design. Our sewage ejector pump guide covers how those pits are vented.
Four places the documents don’t match, and which one to follow.
| Topic | One source says | The other says | Follow |
|---|---|---|---|
| Thread sealant | Oatey: pipe joint compound or thread seal tape | Studor: tape only; pipe dope voids the warranty | Tape, on both brands |
| Warranty | Oatey: 1 year from sale; claim within 30 days of finding it or 13 months | Studor: life of the original drainage system, shipping included | Know which one you bought |
| Oatey 39016 rating | Amazon listing: 20 DFU, vent pipe up to 3 in. | Oatey sheet and product page: 160 branch, 24 stack, 1½ to 2 in. | Oatey’s sheet |
| Maxi-Vent maker | Amazon listing details: Alfi, model GIDDS-301050 | Title, store and photo: Studor 20302 | The valve’s label |
| How long they last | A store blog: 500,000 uses, 20 to 30 years, no source | Studor and Oatey sheets I read: no years figure | The warranty terms |
The sealant rule is the one that costs money. Studor puts the warranty on the line over pipe dope, so tape is the habit to build. Our Teflon tape vs pipe dope guide covers which threads take which. Tape both brands and you never have to remember which valve you’re holding.
An AAV isn’t the only answer for an island or a sink far from a wall. Code has other vents that never wear out.
| Option | How it works | Code | Fits when |
|---|---|---|---|
| Island fixture vent | Vent rises above the drain outlet, then drops and runs to a vent that goes outdoors | IPC 916 | Island sinks and lavatories; the floor is open |
| Wet vent | One fixture’s drain doubles as another fixture’s vent | IPC 912 | Up to two bathroom groups on one floor |
| Individual vent through the roof | Its own pipe up and out | IPC 903 | The wall or attic is open |
| AAV | Valve at the top of the vent pipe, indoors | IPC 918 | None of the above is practical |
An island fixture vent under IPC 916 is limited to sinks and lavatories, though a kitchen sink with a disposer or dishwasher qualifies. The vent has to rise above the fixture’s drain outlet first, and the part below the flood rim is built like drain pipe, with cleanouts (916.3).
Wet venting is often the cleanest fix in a bathroom. Our wet vent guide covers how one pipe can drain one fixture and vent another.
AAV. A Mini-Vent on a riser, or the AAV Tee on tubular parts.
AAV on the branch if code allows; check the 3 in. branch cap of 20 DFU.
Maxi-Vent, if the stack has six branch intervals or fewer.
Open vent through the roof. Code keeps one open in every system.
Open vent, unless an engineer designs it otherwise.
| Question | If yes | If no |
|---|---|---|
| Is this the only vent in the building? | Open vent; an AAV can’t be the only one | Keep going |
| Is the fixture on a different floor from the valve? | Open vent for that fixture. A branch AAV vents only same-floor fixtures (918.3.1); a relief vent doesn’t change that | Keep going |
| Can you reach the valve spot, with air around it? | Keep going | Add a recess box, or vent through the roof |
| Is it 4 in. or more above the branch drain? | Keep going | Raise the riser |
| Is the fixture load under the cap for that pipe size? | AAV works; pick from the table above | Bigger branch or an open vent |
Gurgling or a slow drain after an AAV goes in usually points back to that table. Our toilet gurgling guide walks through venting problems, and the S-trap vs P-trap guide explains why an unvented trap loses its seal.
It lets air in but can’t let pressure out, so one open vent still has to go outdoors. It has a membrane that can wear, it must stay reachable, and some codes don’t recognize it. Oatey’s warranty is 1 year; Studor’s covers the life of the drainage system.
For individual, branch and circuit vents, yes, under IPC 918.3, and for stack vents with a stack-type valve. But not for every vent: IPC 918.7 says at least one stack vent or vent stack in each system goes to the open air.
Under IPC 918.8: in supply or return air plenums, on nonneutralized chemical waste, on sumps or tanks without an engineered vent design, and on outdoor terminals just to cut clearance to an air intake. They also can’t vent fixtures on another floor.
At least 4 in. above the branch or fixture drain it vents, 6 in. above the highest flood rim for a stack valve, and 6 in. above insulation. Keep it upright within 15°, reachable, with air getting in. Fit it after the drain test.
Yes, with Studor’s Mini-Vent, if the standpipe is at least 2 in. and the horizontal drain at least 3 in. That’s Studor’s own rule for washers. A residential washer is 2 fixture units in IPC Table 709.1.
Yes, where your code allows AAVs. A 1.6 gpf toilet is 3 fixture units, and Studor rates the Mini-Vent for bathroom groups on a 3 in. branch up to 20 units. The valve still needs to sit 4 in. above the branch and stay reachable.
Yes. Studor’s manual says locating the valve in a sink or vanity cabinet is acceptable, because air can reach it and you can get to it. Keep it 4 in. above the drain it vents.
They have the same 160 branch and 24 stack rating at 1½ to 2 in. Studor’s warranty covers the life of the drainage system; Oatey’s is 1 year. Studor wants tape only on the threads.
Yes, with limits. Georgia’s plumbing code since Jan 1, 2026 is the 2024 IPC with state amendments, and those amendments don’t change section 918. Your local inspector still has the final say.
Yes. IPC 918.5 and IRC P3114.5 both require access and a spot where air can get in. Inside a wall, that means a recess box with a grille, like the Studor 20380.
Neither maker’s sheet I read gives a years figure. Studor’s warranty runs for the life of the original drainage system. Oatey’s runs 1 year from the date of sale.
It’s a common nickname for an air admittance valve. The code term is air admittance valve, and the same IPC 918 rules apply whatever it’s called.
Written by Isaac Daniels, a licensed journeyman plumber in Georgia (license #JP507711). Code text comes from the 2024 IPC and IRC; ratings and rules from Studor’s and Oatey’s own sheets.