Air admittance valve vs vent

What an AAV can replace, and the vent it can’t.

As an Amazon Associate I earn from qualifying purchases.

On this page
  1. The picks
  2. What an AAV can’t do
  3. Studor Mini-Vent
  4. Oatey Sure-Vent
  5. Studor AAV Tee
  6. Studor Maxi-Vent
  7. Wall box
  8. Side by side
  9. Compare the picks
  10. Where it has to sit
  11. Which valve fits the load
  12. What code allows
  13. Where they’re not allowed
  14. Where sources disagree
  15. Other legal vents
  16. How to choose
  17. Questions
  18. How I compared

Quick answer

An air admittance valve (AAV) lets air in but never out. It can replace a sink or bathroom vent, but code still wants one open vent to the outdoors (IPC 918.7). Match the valve to the pipe and fixture load first.

Reference (not linked): Studor Mini-Vent 20341See its details below.

Four valves for four venting jobs

Only the Oatey Sure-Vent is linked; the Studor parts are reference notes. Ratings come from the makers’ own sheets, not the listings. The wall box for an in-wall valve has its own section further down.

Studor Mini-Vent 20341

Reference (not linked)

Details ↓

Studor Maxi-Vent 20302

Reference (not linked)

Details ↓

What an open vent does that an AAV can’t

Both let air into the drain when water pulls a vacuum. Only the open pipe lets pressure back out.

Open vent through the roof Air in when water pulls a vacuum Air and pressure out when water pushes Air admittance valve Opens on suction, closes by gravity Pressure only seals it tighter: nothing gets out Every building still needs at least one open vent to the outdoors (IPC 918.7). Open vent through the roof Air in when water pulls a vacuum Air and pressure out when water pushes Air admittance valve Opens on suction, closes by gravity Pressure only seals it tighter: nothing gets out Every building still needs one open vent to the outdoors (IPC 918.7).
How each one moves air. Sources: Studor Engineered Products Manual, 10th ed. (membrane opens on vacuum, closes by gravity, seals tighter under pressure); Oatey submittal LCS1501c (“not designed to relieve positive pressure”); IPC 2024 section 918.7.

Water running down a drain drags air with it. If no air can get in behind it, the drain pulls water out of the nearest trap, and an empty trap lets sewer gas into the room. A vent is the air supply that stops that.

An open vent pipe and an AAV both handle that suction. Studor’s manual says its membrane lifts on even a small vacuum and drops shut by gravity once the pressure evens out. There are no springs in it.

Pressure is the other half. Pressure from the sewer or a septic tank pushing back up the pipe needs a way out. An open vent lets it go over the roof. An AAV can’t: Studor says pressure makes it seal even tighter, and Oatey says its valves aren’t designed to relieve it.

That’s why IPC 918.7 keeps at least one stack vent or vent stack open to the outdoors in every plumbing system. Studor goes a step further: one open vent for every building drainage system, so a building with two sewer tie-ins needs two.

Valves for sinks, bathrooms and laundry

Studor Mini-Vent 20341

Studor 20341 Mini-Vent air admittance valve, 1½ to 2 in., PVC adapter

Reference (not linked): This one isn’t linked. The details here are for reference only.

1½ or 2 in. vent160 DFU branch24 DFU stackASSE 1051 and 1050−40 to 150°FPVC adapter

The 20341 is Studor’s Mini-Vent with a PVC adapter, made by IPS Corporation in Collierville, Tennessee. The listing title gives the model, the 1½ to 2 in. connection and the 160 DFU rating.

Studor rates it at 160 drainage fixture units (DFU) on a horizontal branch and 24 DFU on a stack. A DFU is code’s measure of how much a fixture drains: 1 for a bathroom sink, 2 for a tub and 3 for a 1.6 gpf toilet, from IPC Table 709.1.

The drain size caps the load before the valve does. Studor’s branch table limits a Mini-Vent to 3 DFU on a 1½ in. branch, 6 on 2 in., 20 on 3 in. and 160 on 4 in. On most house jobs, the pipe is the real limit, not the 160 on the label.

Inside is a silicone membrane on an ABS body. Studor’s manual says it lifts on a small vacuum, drops back by gravity and seals tighter when the pipe pushes back. That last part is why one open vent per building still has to carry pressure out.

It’s certified to ASSE 1051 for branch use and ASSE 1050 for stacks, and Studor lists ICC-ES report PMG-1025. Studor rates it for −40 to 150°F, with screens inside and outside to keep insects off the membrane.

Studor’s thread rule is strict. Its spec sheet says primer, solvent cement or pipe dope on the threads voids the warranty, so use tape. The install sheet says to hand-tighten only, fit it after the drain test and stand it within 15° of plumb.

The warranty is the long one. Studor’s manual calls it a limited lifetime, meaning the life of the drainage system it’s fitted to, and it covers shipping on the replacement. Labor isn’t covered.

Best for sink and bath branches

Oatey Sure-Vent 39016

Air admittance valve, 1½ to 2 in., PVC Sch. 40 adapter

39016, 1½ or 2 in. PVC Sch. 40 adapter, single valve
$16.99
Check it on Amazon
in stock · price as of Nov 22, 2026, 9:30 AM EST

Pros

  • Same 160 branch and 24 stack DFU rating as the Mini-Vent
  • Oatey publishes its opening point: −0.01 psi
  • Every valve tested at ¼ in. and 30 in. of water, per Oatey
  • Oatey allows tape or pipe joint compound

Cons

  • Warranty is 1 year from the date of sale
  • Claims must be in writing within 30 days of finding the fault
  • Amazon listing says 20 DFU; Oatey’s own sheet says 160
  • Can’t let pressure out, like every AAV
1½ or 2 in. vent160 DFU branch24 DFU stackASSE 1051 and 1050ICC ESR-1664Part 39016

Buy it if

Your parts list is all Oatey, or you want the choice of tape or pipe joint compound, for a sink or bath branch on one floor.

Skip it if

You want the longer warranty. The Studor Mini-Vent has the same rating and covers the life of the drainage system.

The 39016 is Oatey’s Sure-Vent for 1½ to 2 in. pipe, with a PVC Schedule 40 adapter. Oatey is a Cleveland maker of drain and vent supplies. The linked listing is a single valve; a 2-pack is a separate option on the listing.

Oatey’s submittal sheet LCS1501c rates this family at 160 DFU on a branch and 24 on a stack, the same as the Studor Mini-Vent. The stepped adapter takes 1½ or 2 in. vent pipe. Oatey lists ASSE 1050 and 1051, ICC ESR-1664 and NSF 14.

The Amazon listing gets the rating wrong. Its bullets say it’s rated 20 DFU and fits vent pipe up to 3 in. Oatey’s own product page and submittal say 160 branch and 24 stack on 1½ to 2 in. pipe. Go by Oatey; 20 DFU is the rating of its smaller 1½ in. valves.

Oatey publishes more about how its valve opens than Studor does. The submittal says its Sweet Spot membrane opens at −0.01 psi and seals at 0 psi and above, and that every valve is tested at ¼ in. and 30 in. of water column.

Its install rules match the 2024 IPC: fixtures on the same floor, a horizontal branch, at least 4 in. above that branch, 6 in. above insulation and within 15° of vertical. Oatey also says the branch must join the stack within four branch intervals of the top.

On threads, Oatey is looser than Studor. Its sheet says to use approved pipe joint compound or thread seal tape. Tape is the safe habit for both brands, so a later swap to a Studor valve doesn’t void anything.

The warranty is the weak spot. Oatey’s limited warranty runs one year from the date of sale, and a claim has to be in writing within 30 days of finding the problem or 13 months from the sale, whichever comes first. Sure-Vent isn’t on Oatey’s list of longer-warranty products.

My call: it does the same job as the Mini-Vent on a sink or bath branch. Pick it when an all-Oatey parts list or the choice of tape or compound matters more to you than the warranty.

Studor AAV Tee 20391

Studor 20391 AAV Tee with Redi-Vent, 1½ in. tubular connection

Reference (not linked): This one isn’t linked. The details here are for reference only.

1½ in. tubular20 DFU branchPolypropylene teeASSE 1051−40 to 150°FTee alone: 40800

The 20391 is a Studor Redi-Vent valve on a polypropylene tee for 1½ in. tubular drains, the slip-nut kind under most sinks. IPS sells the tee alone as part 40800. This one is the valve and tee together.

Studor’s sheet says it vents up to 20 DFU on a horizontal branch. Its branch caps match the Redi-Vent’s: 3 DFU on 1½ in., 6 on 2 in. and 20 on 3 or 4 in. A kitchen sink is 2 DFU in IPC Table 709.1, even with a disposer and dishwasher, so one sink fits with room to spare.

Studor’s sheet still wants the valve at least 4 in. above the horizontal branch or fixture drain it vents, the same as IPC 918.4. In a shallow cabinet or under a low vanity, measure that height before you buy.

The cabinet is a fine home for it. Studor’s manual says locating the valve in a sink or vanity cabinet is acceptable, because the cabinet lets air reach it and you can get to it. Don’t wall it in behind a false back.

It has the same membrane and the same rules as the Mini-Vent: no springs, shut by gravity, tighter under pressure. Fit it after the drain test, upright within 15° of plumb, with tape and no pipe dope on the threads.

Studor’s sheet calls this valve an alternative to running a vent through the roof or a side wall, for individual, common, circuit, loop and island fixture vents. The warranty is Studor’s limited lifetime, and it’s rated from −40 to 150°F.

It fits best on a sink with no vent pipe nearby: an island, a basement bar sink, or a remodel that moved the sink away from the wall. Where your code allows an AAV there, this is the least new pipe you can add.

The stack valve

Studor Maxi-Vent 20302

Studor 20302 Maxi-Vent air admittance valve, 3 or 4 in.

Reference (not linked): This one isn’t linked. The details here are for reference only.

3 or 4 in. pipe500 DFU stack, 4 in.72 DFU stack, 3 in.160 DFU branch, 4 in.ASSE 10506 in. over flood rim

The 20302 is Studor’s Maxi-Vent for 3 and 4 in. pipe. The Amazon listing sits in the Studor store, and its photo shows the Studor Maxi-Vent and IPS Corporation label.

The listing’s back-end details are messy. They name the maker as Alfi and the model as GIDDS-301050, and one bullet types ASSE 1050 as 10510. The title, the store and the label on the valve all say Studor 20302, so check the label when the box arrives.

It’s a stack-type valve. Studor’s manual rates it at 500 DFU on a 4 in. stack and 72 DFU on a 3 in. stack. On a horizontal branch, it’s 20 DFU on 3 in. and 160 on 4 in., the same caps as the Mini-Vent.

Code puts two limits on any stack valve. IPC 918.3.2 bars it from a stack with more than six branch intervals, and 918.4 puts it at least 6 in. above the flood level rim of the highest fixture it serves. Studor’s own rules say the same.

The joint is simple. On 4 in. pipe, the valve’s rubber gasket pushes onto the pipe. On 3 in. pipe, you take the connector off and use a no-hub coupling. Studor’s install sheet says not to solvent-cement the Maxi-Vent to the pipe.

The one rule it can’t beat is IPC 918.7: every plumbing system keeps at least one stack vent or vent stack open to the outdoors. So the Maxi-Vent caps a second stack, and the main stack still goes through the roof.

Fit it after the drain test, cut the pipe square and stand the valve within 15° of plumb, with air around it and a way to reach it. In an attic, keep it at least 6 in. above the insulation.

The wall box for an in-wall valve

Studor 20380What Studor and the listing say
Size6⅝ in. wide, 8 in. high
Pipe1½ or 2 in. ABS or PVC
In the boxBox, mounting flange, snap-on grille and a gasketed test cap
ValveSold separately: Mini-Vent, Tec-Vent or Redi-Vent, per the listing
ListingsUPC and ICC, per Studor
FitsThe vent riser lands inside a finished wall, such as behind a pedestal sink or in a laundry wall, and the valve has to stay reachable with air around it.
Not neededThe valve sits in an open sink cabinet. Studor says a cabinet already counts, so the AAV Tee or Mini-Vent can go there with no box.

The 20380 is Studor’s recessed box and grille, the part that lets an AAV sit inside a wall and still meet code. The valve isn’t included; the listing names the Mini-Vent, Tec-Vent and Redi-Vent as the valves it takes.

Code is the reason it exists. IPC 918.5 says every AAV needs access and a spot where air can get in. A valve sealed behind drywall fails both. Studor’s manual says to use its recess box and grille for any in-wall installation.

The box and its mounting flange are one piece, so Studor says no extra framing is needed in the stud bay. It connects to 1½ or 2 in. ABS or PVC vent pipe.

A test cap with a rubber gasket is built in. That matters because IPC 918.2 says AAVs go in after the drain, waste and vent test. You test with the cap in place, then thread the valve on at finish.

Where the box does wellWhat to watch
One-piece box and flange; no extra framingBox only; the valve is sold separately
Built-in test cap with gasket for the drain testTakes Studor’s small valves only, per the listing
Snap-on grille lets air in and keeps accessThe grille shows on the finished wall
Takes 1½ or 2 in. ABS or PVCDoesn’t change the 4 in. height rule

The grille snaps on over the opening, and it’s what lets air reach the valve. Don’t paint it shut or hang a mirror over it. If air can’t get in, the valve can’t open.

Height still counts. Set the box so the valve sits at least 4 in. above the branch or fixture drain it vents, under IPC 918.4. A box mounted below the sink’s drain line puts the valve too low.

Studor lists UPC and ICC listings for the box itself. The valve inside carries the DFU rating and the warranty, so choose the valve by its rating first, then use this box to hide it.

When a remodel puts a sink on a wall with no cabinet, the box keeps the AAV reachable and out of sight. Plan the stud bay for it before the drywall goes up.

Reference (not linked): this box isn’t linked here. A box isn’t a valve, so it isn’t compared with the four above.

AAV and open vent side by side

Code sections are from the 2024 IPC, Georgia’s plumbing code since Jan 1, 2026. Scroll sideways on a phone.

CheckAir admittance valveOpen vent pipe
Lets air in on suctionYesYes
Lets pressure outNo, seals tighterYes
Goes through the roof or a wallNoYes, with flashing
Can be the building’s only ventNo (918.7)Yes
Moving partsOne membraneNone
Must stay reachableYes (918.5)No
Fitted before or after the drain testAfter (918.2)Part of the test
Clearance from windows and air intakesCan’t be used just to cut it (918.8)10 ft sideways or 3 ft above (903.5)
Cold-climate rule−40 to 150°F per Studor3 in. minimum through the roof where design temperature is 0°F or below (903.2)
WarrantyStudor: life of the system; Oatey: 1 yearPipe and fittings, by maker

Neither is better at everything. The open vent wins on pressure and has nothing to wear out. The AAV wins where a new roof penetration or a long vent run is the hard part.

The four valves and the wall box compared

Ratings from Studor’s and Oatey’s own sheets. Scroll sideways on a phone.

PartJobPipeBranch ratingStack ratingThread sealantWarranty
Studor Mini-Vent 20341Sinks, bathrooms, laundry1½ or 2 in.160 DFU24 DFUTape onlyLife of the system
Oatey Sure-Vent 39016Sinks, bathrooms1½ or 2 in.160 DFU24 DFUTape or compound1 year
Studor AAV Tee 20391Tubular sink drains1½ in. tubular20 DFUn/a (branch only)Tape onlyLife of the system
Studor Maxi-Vent 20302Second stack3 or 4 in.160 DFU (4 in.)500 DFU (4 in.)None; gasket or couplingLife of the system
Studor 20380 boxValve inside a wall1½ or 2 in.Valve’sn/an/an/a

Where an AAV has to sit

Every height and position rule from code and both makers, in one drawing.

Branch or single fixture Horizontal branch drain 4 in. min. Stack valve Flood rim, highest fixture 6 in. min. In an attic Insulation 6 in. min. Upright, within 15° of plumb Reachable, with air around it Fitted after the drain test Branch or single fixture Horizontal branch drain 4 in. min. Stack valve Flood rim, highest fixture 6 in. min. In an attic Insulation 6 in. min. Upright, within 15° of plumb Reachable, with air around it Fitted after the drain test
Minimum heights for an air admittance valve. Sources: IPC 2024 sections 918.2, 918.4 and 918.5; IRC 2024 P3114.4; Studor Engineered Products Manual installation criteria; Oatey submittal LCS1501c (15° of vertical).
RuleIPC 2024IRC 2024StudorOatey
4 in. above the branch or fixture drain918.4P3114.4YesYes
Stack valve 6 in. above the highest flood rim918.4P3114.4YesNot in its sheet
6 in. above insulation918.4, anywhereP3114.4, atticsYes, atticsYes
Upright, within 15° of plumbNot statedNot statedYesYes
Reachable, with air getting in918.5P3114.5YesNot in its sheet
Fitted after the drain test918.2P3114.2YesNot in its sheet
Same floor, horizontal branch918.3.1P3114.3YesYes
Thread sealantNot statedNot statedTape onlyTape or compound

The 4 in. and 6 in. figures are minimums in both the IPC and IRC. Higher is fine, as long as the valve stays reachable and the vent stays within its length limit.

The 15° rule is the makers’, not code’s. Studor’s membrane closes by gravity, so both Studor and Oatey want the valve close to plumb.

“Within the maximum developed length permitted for the vent” is the line people skip in 918.4. An AAV ends a vent; it doesn’t stretch one. The vent pipe from the trap to the valve still has to meet the same length limits as any other vent, which our trap arm length guide lays out by pipe size.

Which valve covers your fixtures

Add the fixture units on the branch from IPC Table 709.1, then check the cap for that pipe size. Scroll sideways on a phone.

Job on one branchFixture unitsBranch sizeStudor cap at that sizeValve that covers it
Bathroom sink11½ in.3Mini-Vent, Sure-Vent or AAV Tee
Kitchen sink with disposer and dishwasher21½ in.3Mini-Vent, Sure-Vent or AAV Tee
Sink and 5.7 gpm shower1 + 2 = 31½ in.3, at the limitMini-Vent or Sure-Vent
Washing machine23 in. drain, 2 in. standpipe20Mini-Vent (Studor’s washer rule)
Full bath: toilet, sink, tub3 + 1 + 2 = 63 in.20Mini-Vent or Sure-Vent
Two full baths back to back123 in.20Mini-Vent or Sure-Vent
Two baths, kitchen and laundry163 in.20Mini-Vent or Sure-Vent
Same, on a 4 in. branch164 in.160Mini-Vent or Sure-Vent
Second stack in a two-story houseStack load3 or 4 in. stack72 or 500Maxi-Vent

Fixture units are IPC 2024 Table 709.1: lavatory 1, kitchen sink 2, shower up to 5.7 gpm 2, bathtub 2, residential washer 2, 1.6 gpf toilet 3. Branch caps are Studor’s tables for the Mini-Vent; Oatey’s submittal doesn’t give caps by branch size. Your drain must also be sized to code on its own.

The pattern is clear in the table. On a 1½ in. branch, the 3 DFU cap fills up fast, so a sink and a shower on one small branch is as far as it goes. On a 3 in. branch, one Mini-Vent covers a couple of bathrooms.

Washers get their own rule. Studor’s install sheet says that when a Mini-Vent vents a washing machine, the standpipe must be at least 2 in. and the horizontal drain at least 3 in. Our washing machine standpipe guide covers the standpipe height rules.

What each plumbing code says about AAVs

Which code you’re under depends on your state and city. Georgia uses the 2024 IPC with state amendments, and those amendments don’t touch section 918.

CodeWhere it’s usedAAVsKey sections
IPC 2024Georgia since Jan 1, 2026, and other places that adopt itAllowed, with limits918.1 to 918.8
IRC 2024Houses where the IRC plumbing chapters are adopted; Georgia leaves them outAllowed, with limitsP3114.1 to P3114.8
UPC 2024Places that adopt the Uniform Plumbing CodeNo section on themStudor cites 301.2, alternate materials and methods

The IPC and IRC rules are nearly the same: branch and individual valves to ASSE 1051, stack valves to ASSE 1050, same-floor fixtures only, 4 in. and 6 in. heights, access, and one open vent per system.

The IPC adds a ban in plenums and chemical waste systems, a relief vent for branches more than four intervals down, and the six-interval limit on stack valves.

The 2024 UPC is different. I searched IAPMO’s free 2024 UPC text for “air admittance” and got no hits, so it has no section on them at all. Studor lists UPC section 301.2, the alternate materials and methods route, which means your building department decides case by case.

Whatever the book says, your local inspector has the last word, and a city can amend its code. Call before you buy.

Where an AAV isn’t allowed

From IPC 2024 section 918 and the makers’ sheets. Any one of these rules out a valve.

As the building’s only vent

IPC 918.7: at least one stack vent or vent stack goes outdoors in every system.

In supply or return air plenums

IPC 918.8. Studor and Oatey sheets agree.

On chemical waste lines

Not on nonneutralized special waste unless the valve meets ASSE 1049 and the other 918.8 tests.

On sumps, tanks and ejector pits

Only where an engineer designed the vent system (918.8). Oatey and Studor also want local approval first.

To dodge a window clearance

918.8 bars an AAV on an outdoor vent terminal just to get closer to an air intake.

On a stack over six branch intervals

918.3.2 for stack valves. Branch valves more than four intervals down need a relief vent (918.3.1).

For fixtures on another floor

918.3.1: branch valves vent only same-floor fixtures on a horizontal branch.

Sealed in a wall

918.5 needs access and air. Use a recess box and grille.

Sewage pits come up often. As a sealed ejector pit fills, the rising water pushes air out of it, and that’s pressure an AAV can’t release. Code allows a valve there only with an engineered design. Our sewage ejector pump guide covers how those pits are vented.

Where the makers and listings disagree

Four places the documents don’t match, and which one to follow.

TopicOne source saysThe other saysFollow
Thread sealantOatey: pipe joint compound or thread seal tapeStudor: tape only; pipe dope voids the warrantyTape, on both brands
WarrantyOatey: 1 year from sale; claim within 30 days of finding it or 13 monthsStudor: life of the original drainage system, shipping includedKnow which one you bought
Oatey 39016 ratingAmazon listing: 20 DFU, vent pipe up to 3 in.Oatey sheet and product page: 160 branch, 24 stack, 1½ to 2 in.Oatey’s sheet
Maxi-Vent makerAmazon listing details: Alfi, model GIDDS-301050Title, store and photo: Studor 20302The valve’s label
How long they lastA store blog: 500,000 uses, 20 to 30 years, no sourceStudor and Oatey sheets I read: no years figureThe warranty terms

The sealant rule is the one that costs money. Studor puts the warranty on the line over pipe dope, so tape is the habit to build. Our Teflon tape vs pipe dope guide covers which threads take which. Tape both brands and you never have to remember which valve you’re holding.

Other ways to vent a hard-to-reach fixture

An AAV isn’t the only answer for an island or a sink far from a wall. Code has other vents that never wear out.

OptionHow it worksCodeFits when
Island fixture ventVent rises above the drain outlet, then drops and runs to a vent that goes outdoorsIPC 916Island sinks and lavatories; the floor is open
Wet ventOne fixture’s drain doubles as another fixture’s ventIPC 912Up to two bathroom groups on one floor
Individual vent through the roofIts own pipe up and outIPC 903The wall or attic is open
AAVValve at the top of the vent pipe, indoorsIPC 918None of the above is practical

An island fixture vent under IPC 916 is limited to sinks and lavatories, though a kitchen sink with a disposer or dishwasher qualifies. The vent has to rise above the fixture’s drain outlet first, and the part below the flood rim is built like drain pipe, with cleanouts (916.3).

Wet venting is often the cleanest fix in a bathroom. Our wet vent guide covers how one pipe can drain one fixture and vent another.

Should you use an AAV or a vent pipe?

Sink or vanity, no vent nearby

AAV. A Mini-Vent on a riser, or the AAV Tee on tubular parts.

Bathroom on one floor

AAV on the branch if code allows; check the 3 in. branch cap of 20 DFU.

Second stack far from the main

Maxi-Vent, if the stack has six branch intervals or fewer.

The main stack

Open vent through the roof. Code keeps one open in every system.

Ejector pit or sump

Open vent, unless an engineer designs it otherwise.

QuestionIf yesIf no
Is this the only vent in the building?Open vent; an AAV can’t be the only oneKeep going
Is the fixture on a different floor from the valve?Open vent for that fixture. A branch AAV vents only same-floor fixtures (918.3.1); a relief vent doesn’t change thatKeep going
Can you reach the valve spot, with air around it?Keep goingAdd a recess box, or vent through the roof
Is it 4 in. or more above the branch drain?Keep goingRaise the riser
Is the fixture load under the cap for that pipe size?AAV works; pick from the table aboveBigger branch or an open vent

Gurgling or a slow drain after an AAV goes in usually points back to that table. Our toilet gurgling guide walks through venting problems, and the S-trap vs P-trap guide explains why an unvented trap loses its seal.

Questions people ask

What are the downsides of an air admittance valve?

It lets air in but can’t let pressure out, so one open vent still has to go outdoors. It has a membrane that can wear, it must stay reachable, and some codes don’t recognize it. Oatey’s warranty is 1 year; Studor’s covers the life of the drainage system.

Can I use an air admittance valve instead of a vent?

For individual, branch and circuit vents, yes, under IPC 918.3, and for stack vents with a stack-type valve. But not for every vent: IPC 918.7 says at least one stack vent or vent stack in each system goes to the open air.

Where are air admittance valves not allowed?

Under IPC 918.8: in supply or return air plenums, on nonneutralized chemical waste, on sumps or tanks without an engineered vent design, and on outdoor terminals just to cut clearance to an air intake. They also can’t vent fixtures on another floor.

Where should an air admittance valve be located?

At least 4 in. above the branch or fixture drain it vents, 6 in. above the highest flood rim for a stack valve, and 6 in. above insulation. Keep it upright within 15°, reachable, with air getting in. Fit it after the drain test.

Can you use an air admittance valve for a washing machine?

Yes, with Studor’s Mini-Vent, if the standpipe is at least 2 in. and the horizontal drain at least 3 in. That’s Studor’s own rule for washers. A residential washer is 2 fixture units in IPC Table 709.1.

Can a toilet be vented with an AAV?

Yes, where your code allows AAVs. A 1.6 gpf toilet is 3 fixture units, and Studor rates the Mini-Vent for bathroom groups on a 3 in. branch up to 20 units. The valve still needs to sit 4 in. above the branch and stay reachable.

Can an air admittance valve go under a sink?

Yes. Studor’s manual says locating the valve in a sink or vanity cabinet is acceptable, because air can reach it and you can get to it. Keep it 4 in. above the drain it vents.

Is Studor or Oatey better?

They have the same 160 branch and 24 stack rating at 1½ to 2 in. Studor’s warranty covers the life of the drainage system; Oatey’s is 1 year. Studor wants tape only on the threads.

Are air admittance valves legal in Georgia?

Yes, with limits. Georgia’s plumbing code since Jan 1, 2026 is the 2024 IPC with state amendments, and those amendments don’t change section 918. Your local inspector still has the final say.

Do air admittance valves need to be accessible?

Yes. IPC 918.5 and IRC P3114.5 both require access and a spot where air can get in. Inside a wall, that means a recess box with a grille, like the Studor 20380.

How long does an air admittance valve last?

Neither maker’s sheet I read gives a years figure. Studor’s warranty runs for the life of the original drainage system. Oatey’s runs 1 year from the date of sale.

What is a cheater vent?

It’s a common nickname for an air admittance valve. The code term is air admittance valve, and the same IPC 918 rules apply whatever it’s called.

How I compared them

Why trust me

Written by Isaac Daniels, a licensed journeyman plumber in Georgia (license #JP507711). Code text comes from the 2024 IPC and IRC; ratings and rules from Studor’s and Oatey’s own sheets.

How I compared

  • Only figures the makers, the IPC and the IRC publish, read Oct 21, 2026.
  • Valves are matched by job, pipe and rating, with no score. The Studor wall box has its own section.
  • Fixture-unit sums are my arithmetic from IPC Table 709.1.
  • Links go to listings sold by Amazon.com.

Sources

  • International Plumbing Code 2024 (ICC): sections 903.1, 903.2, 903.5, 912, 916.1 to 916.3 and 918.1 to 918.8, and Table 709.1. Georgia DCA amendments to the 2024 IPC, effective Jan 1, 2026 (none to 903, 916 or 918).
  • International Residential Code 2024 (ICC): P3114.1 to P3114.8.
  • IAPMO 2024 Uniform Plumbing Code, free e-book: full-text search for “air admittance”.
  • Oatey: submittal LCS1501c (07/25), 39016 product page, limited warranty page.
  • Studor (IPS Corporation): Engineered Products Manual, 10th ed.; spec and install sheets for the Mini-Vent 20341, Redi-Vent, AAV Tee 20391 and Maxi-Vent; 20380 recess box page.
  • Amazon product listings for every product named on this page, read Oct 22, 2026.