Bradford White ICON status light codes

I read Bradford White ICON status light codes by control version first, then match the flash pattern to the service chart.

As an Amazon Associate I earn from qualifying purchases. How this site earns

Fluke 117 digital multimeter, for qualified service providers checking the thermopile
Fluke 117 thermopile meter. Product photo: Amazon.
On this page
  1. The picks
  2. Which ICON you have
  3. All gas codes
  4. Safety first
  5. Side by side
  6. ICON 2.0 codes
  7. ICON 1.0 codes
  8. ICON E electric codes
  9. Two flashes
  10. Four flashes
  11. No light
  12. Common mistakes
  13. Questions
  14. How I choose

The short answer

I check the control version first: on gas ICON 1.0, two quick flashes with the burner heating are normal, while two fault flashes with the burner off indicate a weak pilot signal. If you smell gas, leave the building and call your gas supplier from outside.[2][4]

Fluke 117 digital multimeter for testing a water heater thermopile
Tech’s thermopile meter: Fluke 117$207.01 at AmazonPrice as of Nov 22, 2026, 9:30 AM EST
Check it on Amazon
Professional pilot tests
Fluke 117
Catching a tank leak
Everflow AWHP22
A separate water alarm
Resideo RWD21
Find the right control chart

Three tools and two reference parts, matched to the codes

Each one answers a specific code: a meter for the pilot tests, a valve kit and pilot for the parts Bradford White lists, and a pan and alarm for leaks. I keep the valve kits and pilot as unlinked service references; a qualified provider must confirm fit.

Fluke 117 digital multimeter

Product photo: Amazon

Best for a tech’s 2-flash thermopile test

Fluke 117

$207.01 at Amazon
Check it on Amazon
Price as of Nov 22, 2026, 9:30 AM EST
Buy it if
Your plumber or service tech needs a meter for the two-flash thermopile test, the thermal switch continuity test or an ICON E temperature sensor reading.
Skip it if
You only want to read the code and call a pro. Counting flashes needs no tools.
The tradeoff
I reserve live gas-appliance measurements for a qualified service provider. Counting the light pattern needs no meter.
Reference (not linked)

Bradford White 415-52907 kits

Reference only. I leave the service-part selection to a qualified provider using the heater model and serial number.

Reference (not linked)

Bradford White 233-47845-05

Reference only. I leave the service-part selection to a qualified provider using the heater model and serial number.

Everflow AWHP22 aluminum water heater drain pan

Product photo: Amazon

Best for catching a tank leak

Everflow AWHP22

$27.06 at Amazon
Check it on Amazon
Price as of Nov 22, 2026, 9:30 AM EST
Buy it if
Your heater’s base measures under 22 in. across, there’s no pan under it now, and you can run a 1 or 1-1/2 in. drain line from the pan’s fitting.[10]
Skip it if
Your heater is wider than 22 in. at the base. Measure first and size up to a pan that clears it.[10]
The tradeoff
I measure the tank base and plan the drain route before choosing the pan. A pan catches leakage; it does not repair the tank.
Resideo RWD21 water leak alarm

Product photo: Amazon

Best for a leak alarm without the ICON module

Resideo RWD21

$10.99 at Amazon
Check it on Amazon
Price as of Nov 22, 2026, 9:30 AM EST
Buy it if
Your heater has no Bradford White accessory module, and you want a loud alarm on the floor beside the tank or in the pan.
Skip it if
You want the ICON valve itself to report a leak. That takes Bradford White’s own accessory module, which your plumber can confirm for your model.
The tradeoff
I use this as a separate audible water alarm. It does not add the Bradford White accessory module’s leak code.

On a phone, scroll this table sideways to read every column.

ToolKey specsPick it ifSkip it if
Fluke 117Fluke 117, DC V 6.000 V / 0.001 V, DC mV 600.0 mV / 0.1 mV, CAT III 600 V, 40.00 MΩ max, 9 V, 400 h typical[9]Your plumber or service tech needs a meter for the two-flash thermopile test, the thermal switch continuity test or an ICON E temperature sensor reading.You only want to read the code and call a pro. Counting flashes needs no tools.
Bradford White 415-52907 kits (reference)415-52907-01, 415-52907-02, ICON 2.0, Natural gas, Millivolt powered, Piezo igniter[7][10]Reference (not linked). Fits when a plumber has confirmed the valve is the fault, such as a seven-flash code that comes back after a reset or an eight-flash pilot that stays lit with the knob off, and your model and serial match one of these kits.Your heater burns LP, its parts list calls for a White Rodgers valve, or nobody has tested the pilot, sensor and gas pressure yet.
Bradford White 233-47845-05 (reference)233-47845-05, Kit 415-47845-05, Natural gas, Resideo valve models, Genuine OEM, Made in USA[7][10]Reference (not linked). Fits when a two-flash code keeps coming back, the thermopile reads under 350 mV, and the resettable thermal switch tests closed, so Bradford White’s manual points to the pilot assembly.[4][7]Your parts list shows a White Rodgers valve, the heater burns LP, or the thermal switch is open. Bradford White says an open switch is possibly from overheating, and the cause must be found first.
Everflow AWHP22AWHP22, Aluminum, 22 in. base, 24 in. top, 2.5 in. deep, 1 to 1-1/2 in. PVC[10]Your heater’s base measures under 22 in. across, there’s no pan under it now, and you can run a 1 or 1-1/2 in. drain line from the pan’s fitting.[10]Your heater is wider than 22 in. at the base. Measure first and size up to a pan that clears it.[10]
Resideo RWD21RWD21, Resideo, 1/16 in. water, Audible alarm, Reusable, Spot detector[10]Your heater has no Bradford White accessory module, and you want a loud alarm on the floor beside the tank or in the pan.You want the ICON valve itself to report a leak. That takes Bradford White’s own accessory module, which your plumber can confirm for your model.

Find the right ICON chart

I start with fuel type and the control generation. This chart selector cannot replace a test or an in-person check.

Check the rating plate and confirm the control before choosing a chart.

Which ICON control do you have?

Bradford White prints separate code charts for ICON 1.0, ICON 2.0 and the electric ICON E. The same flash count can mean different things, so start here.[1][2][5]

Your Bradford White heaterwith an ICON status lightElectric, LED andsetpoint knobGas, LED on the gas valvefind the serial on the rating plate;check its date with Bradford WhiteICON E chartgreen, amber and red codesBefore TAICON 1.0 chartAfter TAICON 2.0 chartAt or near TA (Jan 2019)call BW: 800-334-3393Valve replaced? The new one may bea newer generation; confirm with BW.Sources: Bradford White 238-55592-00A, 238-55593-00A, ICON E 238-54399-00B, bradfordwhite.com FAQ. Your Bradford White heaterwith an ICON status lightElectricLED, setpoint knobGasLED on gas valveICON E chartgreen, amber, redCheck the dateserial on ratingplate; ask BWBefore TAICON 1.0 chartAfter TAICON 2.0 chartAt or near TA (Jan 2019)call BW: 800-334-3393Valve replaced? The new one may be anewer generation; confirm with BW.Sources: Bradford White 238-55592-00A,238-55593-00A, ICON E 238-54399-00B,bradfordwhite.com FAQ.
From Bradford White quick service guides 238-55593-00A (ICON 2.0) and 238-55592-00A (ICON 1.0) and quick start guide 238-54399-00B (ICON E).

Gas or electric comes first. A gas ICON heater has its status light on the gas valve at the bottom of the tank. An ICON E electric heater has an LED and a setpoint knob on its electronic control, and it uses colored flashes with a four-second pause.

On gas heaters, the generation follows the manufacture date. Bradford White’s quick guide labels ICON 2.0 for heaters with serial date code “TA” (January 2019) and later, and ICON 1.0 for “TA” and prior.[1][2]

To get the date, Bradford White’s FAQ points to its My Water Heater Information page, which reads it from the serial number on the rating plate. The quick guide also names the For The Pro contractor app.

If your serial is at or near January 2019, the quick guide says to call Bradford White technical support at 800-334-3393 to confirm the generation. A valve that’s been replaced may also differ from the original, since the 415-52907 kits are sold to replace earlier ICON valves.[1][2][7]

Every ICON gas code, side by side

Green rows are normal operation. Amber rows are faults to check. Grey cells mean that code isn’t on that generation’s chart.

What you seeICON 1.0 (TA and before)ICON 2.0 (TA and later)No lightPilot out or heaternot running: relightPilot out or heaternot running: relightOne flash, thena pause3 s pause: pilot on,idle or satisfied4 s pause: pilot on,idle or satisfiedWhile the burneris heatingStrobe: two quickflashes, 3 s pauseOne flash everysecondLight on solidKnob just turned off:wait for it to go outKnob just turned off:wait for it to go out2 flashes, 3 s pauseWeak pilot signalWeak pilot signal3 flashes, 3 s pauseNo temperature risein the expected timeNot on the2.0 chart4 flashes, 3 s pauseHigh tank temperatureHigh tank temperature5 flashes, 3 s pauseThermostat sensor faultThermostat sensor fault6 flashes, 3 s pauseLeak found by theaccessory moduleLeak found by theaccessory module7 flashes, 3 s pauseGas valve faultNot on the2.0 chart8 flashes, 3 s pausePilot stays lit withthe knob offNot on the2.0 chartNormal operationA fault to checkNot on that chartSource: Bradford White ICON quick service guides 238-55592-00A (1.0) and 238-55593-00A (2.0). Serial date code TA = Jan 2019. You seeICON 1.0TA and beforeICON 2.0TA and laterNo lightPilot out:relightPilot out:relight1 flash,then pause3 s pause:idle, normal4 s pause:idle, normalWhileheatingDouble strobe,3 s pause1 flash everysecondSolid onKnob just off:waitKnob just off:wait2 flashesWeak pilotsignalWeak pilotsignal3 flashesNo temp risein timeNot on2.0 chart4 flashesHigh tanktemperatureHigh tanktemperature5 flashesSensor faultSensor fault6 flashesLeak, if themodule is fittedLeak, if themodule is fitted7 flashesGas valvefaultNot on2.0 chart8 flashesPilot lit,knob offNot on2.0 chartNormalFault to checkNot on chartSource: Bradford White quick service guides238-55592-00A and 238-55593-00A.Serial date code TA = Jan 2019.
From Bradford White quick service guides 238-55593-00A and 238-55592-00A. Fault codes repeat after a three-second pause.

The normal patterns are where owners get confused. On ICON 1.0, one flash and a three-second pause means the knob is in pilot or the water is hot. On ICON 2.0 the same state is one flash with a four-second pause.[1][2]

Heating looks different too. ICON 1.0 shows a strobe, two quick flashes and a three-second pause, while the burner runs. ICON 2.0 shows one flash every second. Neither is a fault.[1][2]

The trap is the ICON 1.0 strobe. Two quick flashes look a lot like the two-flash weak pilot code. Watch the timing: the strobe’s flashes come close together, and the burner should be lit. A true two-flash code comes with the main burner off.[2]

Codes 3, 7 and 8 exist only on ICON 1.0. If an ICON 2.0 valve seems to show seven flashes, count again through two full cycles, from one pause to the next.[1][2][4]

What to do first, and what to leave to a pro

Bradford White says the lights are there to help the professional plumber, and its service manual is written for qualified service providers only.

If you smell gas

Don’t try to light any appliance. Don’t touch any electrical switch or use any phone in the building. Call your gas supplier from a neighbor’s phone, or the fire department if you can’t reach them. That’s the instruction in Bradford White’s gas service manual.

If your sense of smell is weak

Bradford White warns that odorant fade can make gas harder to smell. If you’re unsure whether there’s gas, call your supplier from a neighbor’s phone, and ask your supplier or plumber about gas detectors.

What an owner can do

Read and record the code, relight the pilot by the label on the heater, and look for water around the base. A four-flash lockout reset comes from Bradford White’s service manual, which is for qualified service providers, so call one.

What belongs to a pro

Thermopile and sensor tests, gas pressure checks, thermal switch resets and part swaps. Bradford White’s manual says its service steps are “to be performed ONLY by qualified service providers.”

3 linked, 2 references, side by side

What each one does and which codes it serves. Scroll sideways on a phone.

On a phone, scroll this table sideways to read every column.

PickPhotoCodes it servesWhat it doesShort pros / consBuy
Fluke 117
Thermopile and switch tests
Fluke 1172 flashes, no light, ICON E 2 and 4 amber[4][5]Reads 350 to 850 mV on its 6 V range; continuity; ohms[4][9]1 mV DC resolution / Ohms stop at 40 MΩ[9]Check it on Amazon
BW 415-52907-01
1 in. ICON 2.0 kit
ICON 1.0: 7 and 8; 3 to 5 if the valve is faulty[2][4]Replaces the gas controlGenuine BW kit / Reference onlyReference (not linked)
BW 415-52907-02
2 in. ICON 2.0 kit
ICON 1.0: 7 and 8; 3 to 5 if the valve is faulty[2][4]Replaces the gas controlGenuine BW kit / Reference onlyReference (not linked)
BW 233-47845-05
Pilot assembly
2 flashes, after the meter tests[2][4]Replaces pilot and thermopile assemblyGenuine BW part / Resideo models onlyReference (not linked)
Everflow AWHP22
Drain pan
Everflow AWHP226 flashes, gas heaters[1][2][4]Catches water under the tankFitting included / 22 in. base only[10]Check it on Amazon
Resideo RWD21
Leak alarm
Resideo RWD21Any heater without the moduleSounds at 1/16 in. of water[10]Reusable / Not tied to the valveCheck it on Amazon

Green marks a strength and amber marks a limit.

ICON 2.0 codes: January 2019 and later

Bradford White’s quick service guide 238-55593-00A covers atmospheric and direct vent heaters with serial date code TA and later.[1]

On a phone, scroll this table sideways to read every column.

Light patternWhat it meansBradford White’s service actionPossible parts
No lightNo pilot; heater not runningFollow the lighting instructions on the heaterNone
One flash, four-second pauseKnob in pilot, or water is up to temperatureNoneNone
One flash every secondThermostat calling for heatNoneNone
Solid onNot an error: knob turned off, control shutting downWait until the light goes out before relightingNone
Two flashes, three-second pauseWeak pilot signalVerify the pilot is lit; check thermopile voltage; check wire connections at the gas valvePilot assembly, then gas valve
Four flashes, three-second pauseHigh tank temperatureCheck temp probe ohms; check if the tank is above setpoint; verify no heat migration in the plumbingGas valve cover with temp probe, then gas valve
Five flashes, three-second pauseThermostat sensor faultCheck temp probe ohms and a tight connection; replace the gas valveGas valve cover with temp probe, then gas valve
Six flashes, three-second pauseLeak found by the accessory moduleSee the accessory module’s troubleshootingPer the accessory module

From Bradford White quick service guide 238-55593-00A, page 1. Its general note also says to check all wire connections, gas inlet and manifold pressure, and grounding connections.[1]

The service manual’s ICON V2 chart adds color. Green is normal operation, yellow is low thermopile voltage on the two-flash code, and red marks the four- and five-flash faults. The solid light after shutoff is also red, but the chart says it isn’t an error.[4]

The four-flash row lists three checks before any part: the probe’s ohms, whether the tank really is above setpoint, and that there’s no heat migration in the plumbing system. Parts come after those checks.

ICON 1.0 codes: January 2019 and earlier

Quick service guide 238-55592-00A covers the earlier valve. It has three codes ICON 2.0 doesn’t: 3, 7 and 8.[1][2][4]

On a phone, scroll this table sideways to read every column.

Light patternWhat it meansBradford White’s service actionPossible parts
No lightNo pilot; heater not runningFollow the lighting instructions on the heaterNone
One flash, three-second pauseKnob in pilot, or water is up to temperatureNoneNone
Strobe: two quick flashes, three-second pauseThermostat calling for heatNoneNone
Light on continuouslyKnob turned to offWait for the light to go off before relightingNone
Two flashes, three-second pauseWeak pilot signalVerify the pilot is lit; check thermopile voltage; check wire connections at the gas valvePilot assembly, then gas valve
Three flashes, three-second pauseNo temperature rise in the expected timeCheck temp probe ohmsGas valve cover with temp probe
Four flashes, three-second pauseHigh tank temperatureCheck temp probe ohms; check tank vs setpoint; verify no heat migrationGas valve cover with temp probe, then gas valve
Five flashes, three-second pauseThermostat sensor faultCheck temp probe ohms and a tight connection; replace the gas valveGas valve cover with temp probe
Six flashes, three-second pauseLeak found by the accessory module, if installedSee the accessory module’s troubleshootingPer the accessory module
Seven flashes, three-second pauseGas valve faultReset the gas valve; replace it if the code persistsGas valve
Eight flashes, three-second pausePilot stays lit with the knob offCheck gas pressure; replace the gas valveGas valve

From Bradford White quick service guide 238-55592-00A. Bradford White’s atmospheric ICON sheet adds “verify water is not flowing” to the three-flash row.[2][3]

The service manual’s ICON V1 chart explains a few rows further. For three flashes it says the system resets on its own, and it names a thermal sensor out of calibration or a faulty gas control. Its fix is a new gas control.[4]

For seven flashes, the manual says the control needs a reset, or that it’s wet or physically damaged. For eight, it names a pilot valve stuck open. Shut the gas off at the heater’s manual valve and call a pro; a pilot that won’t go out with the knob off isn’t something to live with.

ICON E codes on electric heaters

The electric ICON E control uses green, amber and red flashes, each followed by a four-second off period. Quick start guide 238-54399-00B lists them.[5][6]

On a phone, scroll this table sideways to read every column.

Light patternWhat it meansBradford White’s service actionPossible parts
No lightNo power reaching the controlA pro turns the power off first, then checks the supply, the control’s connectors and the high limit wires; if it persists, the control module is replacedControl module, if the fault persists
Amber-green, continuousFirst 5 seconds after power on, or StartGuard self-check[5]None; the control is workingNone
Solid greenThermostat satisfiedNoneNone
One green flashWater is heatingNoneNone
Two amber flashesHeating element faultPower off, remove element wires, check ohms across the terminalsHeating element(s)
Three amber flashesPower Switch Module (PSM) faultPower off and replace the PSMPSM
Four amber flashesTemperature sensor faultPower off, check wires and terminals; replace the upper sensor, then the PSM if it returnsUpper temperature sensor, then PSM
Five amber flashesController faultReplace the ICON E electronic controlICON E control
Six amber flashesUtility demand response eventAdjust the setpoint to overrideNone
Seven red flashesHigh temperatureCheck whether the high limit tripped; power off and check the PSM terminals for shortsUpper sensor or PSM, as diagnosis shows

From Bradford White ICON E quick start guide 238-54399-00B (Rev. 11/22) and the ICON electric service manual 55036. The manual warns of high voltage exposure during voltage checks.[5][6]

StartGuard runs on a new heater and after the tank is drained to replace a burned-out element. Bradford White’s manual says it starts only if the setpoint knob is moved after power is applied, to a setting that calls for heat. It checks for a full tank and working elements in under 5 minutes.[6]

If amber-green lasts much longer than 5 minutes, the manual says there may be air in the tank or a damaged control. Otherwise the light changes to one green flash while heating.[6]

Six amber flashes isn’t a fault. The manual says it’s a Load Shed command from a utility program. Moving the setpoint knob away and back lets the heater run normally for 72 hours.[6]

Those utility programs usually require a setpoint of 140°F or higher, the manual says. Bradford White warns that 140°F water scalds in five seconds or less and strongly recommends an ASSE approved mixing valve at those settings.[6]

Solid green with no hot water has its own fix in the manual: move the knob around and back to the setpoint. That should start StartGuard, or one green flash if StartGuard already ran.

Two flashes: what your service tech will do

The pilot heats a thermopile, which powers the ICON valve with millivolts. Bradford White publishes the normal range.

Thermocouple on a mechanical valve, for comparison20 to 30 mVBottom of normal thermopile output350 mVTop of the Fluke 117’s DC mV setting600 mVTop of normal thermopile output850 mVThermocouple on a mechanical valve, for comparison20 to 30 mVBottom of normal thermopile output350 mVTop of the Fluke 117’s DC mV setting600 mVTop of normal thermopile output850 mV
From Bradford White gas service manual 238-51542-00, Service Procedure RG-II, and Fluke’s 117 specifications. Bar lengths are on a 1000 mV scale.
  1. 1

    The tech holds the knob in pilot

    With the pilot lit, Bradford White’s procedure has the tech turn the knob to pilot and keep it pressed.

  2. 2

    The tech frees the red wire

    Still pressing the knob, the tech removes the red (+) wire from the resettable thermal switch.

  3. 3

    The tech measures to ground

    The meter’s positive lead goes on the thermal switch terminal and the negative on an earth ground. On a meter whose mV range stops at 600, the tech uses the 6 V DC range.[4][9]

  4. 4

    The tech reads the result

    Between 350 and 850 mV is normal. The tech then reconnects the red wire to the gas control’s positive terminal, releases the knob and sets the temperature.[4]

  5. 5

    Under 350 mV

    The tech tests the resettable thermal switch next. If it’s closed, Bradford White recommends replacing the pilot assembly.

This is a live gas appliance with the pilot burning, so it’s a job for a qualified service provider. The steps above are Bradford White’s procedure RG-II as your tech does it. They’re here so you know what’s being checked and why, not for you to do yourself.

Don’t mix up the two kinds of pilot generator. Bradford White’s manual tests an old-style thermocouple on a mechanical White Rodgers valve at 20 to 30 mV, a fraction of an ICON thermopile’s output. A reading in that range on an ICON heater means something is wrong.[4]

Four flashes: resetting a high temperature lockout

Four flashes means the control saw the tank get too hot and shut down. Bradford White’s service manual gives the reset below for qualified service providers; it’s here so you know what the pro will do, not as an owner task.

  1. 1

    Knob to off

    Turn the gas control knob to the OFF position.

  2. 2

    Wait five minutes

    Wait a minimum of five minutes, Bradford White says.

  3. 3

    Relight by the label

    Follow the lighting instructions on the heater’s label, or in the installation and operation manual.

  4. 4

    Set the temperature

    Return the knob to your setpoint.

  5. 5

    Watch the light

    If four flashes come back, the manual moves on to testing the temperature sensor, which means taking the valve apart. That’s for a pro.

A lockout that keeps returning has a cause. The ICON 2.0 quick guide lists three checks: the temperature probe’s ohms, whether the tank really is above setpoint, and heat migration in the plumbing. The manual’s V1 chart adds a sensor out of calibration or a faulty control.[1][4]

The sensor test needs care. Bradford White says not to use standard multimeter probes on the sensor connector, since they damage it; it calls for pin-type probes or small wire pins. The tank temperature for that test comes from water drawn at the drain valve, measured with an accurate thermometer.

No light, and a pilot that won’t stay lit

No light means the valve has no power from the pilot. Relight by the label first. If the pilot won’t stay lit, the resettable thermal switch is next.

Thermal switch colorOpens at about
Blue240°F[4]
Yellow270°F[4]
Red290°F[4]

From Bradford White gas service manual 238-51542-00, resettable thermal switch color code reference. The switch opens at a set temperature that depends on the model.[4]

Bradford White’s flammable vapor resistant heaters have a calibrated thermal switch on the combustion chamber. The manual says it shuts down the pilot and burner if flammable vapors burn inside, or if lint, dust or oil clog the flame arrestor and starve the burner of air.

A qualified service provider can reset an open switch with its red button. The manual is firm that the overheating cause must be found before the heater goes back in service. Its listed causes are not enough combustion air, a weak or wrong switch, and a flammable vapor incident.

The air fixes, done by a qualified service provider, are clearing the jacket’s slot openings and cleaning the flame arrestor plate with a stiff brush or compressed air. After a flammable vapor incident, Bradford White’s answer is to replace the water heater. Our pilot light guide covers the other causes.

Mistakes people make with ICON lights

Six ways the light gets misread, and what Bradford White’s documents say instead.

Reading the wrong chart

Two quick flashes is normal heating on ICON 1.0 and close to the weak pilot code on either version. Check the serial date before you decide.[2]

Relighting while the light is solid

Both quick guides say to wait until the solid light goes out after the knob is turned off, then relight.

Pressing the thermal switch reset and walking away

Bradford White says the overheating cause must be found before the heater goes back in service.

Living with an eight-flash code

The pilot staying lit with the knob off points to a pilot valve stuck open. Shut off gas to the heater and call a pro.

Standard probes on the sensor plug

Bradford White says they damage the connector. The test calls for pin-type probes or small wire pins.

Expecting a leak code without the module

Six flashes on gas ICON heaters needs the accessory module. On ICON E, six amber flashes is a utility event, not a leak.

Questions people ask

Why is my Bradford White water heater’s green light blinking?

A slow single blink is normal. On ICON 2.0 it’s one flash with a four-second pause when the knob is in pilot or the water is hot, and one flash a second while heating. On ICON 1.0 it’s one flash with a three-second pause, or a quick two-flash strobe while heating.[1][2]

What do two flashes mean on a Bradford White water heater?

Two flashes and a three-second pause is a weak pilot signal on both ICON versions. Bradford White says to verify the pilot is lit, check thermopile voltage and check the wire connections at the gas valve. Normal thermopile output is 350 to 850 mV.[2][4]

What color should the status light be?

On the ICON V2 control in Bradford White’s service manual, green is normal, yellow is low thermopile voltage and red is a valve fault, except the solid red light after shutoff, which the chart says isn’t an error. On ICON E electric heaters, green is normal, amber is a fault or utility event, and seven red flashes is high temperature.[4][5]

How do I reset a Bradford White water heater?

For a four-flash high temperature lockout, Bradford White’s service manual, which is written for qualified service providers, has the technician turn the knob to OFF, wait at least five minutes, relight by the label and set the temperature. Have a qualified service provider do it, because a tank that overheated has a cause to find. If the code returns, the pro tests the temperature sensor.

What does seven flashes mean on a Bradford White?

On ICON 1.0 it’s a gas valve fault. Bradford White says to reset the gas valve, and to replace it if the code persists. ICON 2.0’s chart has no seven-flash code.[1][2]

What does eight flashes mean?

If you smell gas, leave and call the gas supplier or fire department from outside. On ICON 1.0, eight flashes means the pilot is staying lit with the knob turned off. Bradford White’s manual names a pilot valve stuck open; its fix is to check gas pressure and replace the gas valve. Shut the gas off at the heater’s valve and call a pro.[2][4]

Why is there no status light on my water heater?

On ICON E, no light means no power is reaching the control. On a gas ICON heater, the pilot is out; relight by the label. If it won’t stay lit, Bradford White’s manual says to replace the pilot assembly, then the gas control. A tripped resettable thermal switch also cuts the valve’s power, so a pro checks it too.

What does five flashes mean on a Bradford White?

On a gas ICON valve, it’s a thermostat sensor fault: Bradford White says to check the temperature probe’s ohms and its connection, then replace the gas valve. On ICON E, five amber flashes is a controller fault, and the fix is a new ICON E control.

How do I reset the flammable vapor sensor?

There is no owner reset for a vapor shutdown. The red button belongs to the resettable thermal switch, which trips on combustion-chamber overheating; it is not a vapor sensor. Bradford White says a qualified provider must find the overheating cause before the heater goes back in service, and after a flammable vapor incident it says to replace the heater, not reset it.

How do I know if I have ICON 1.0 or 2.0?

Bradford White labels ICON 2.0 for serial date code TA (January 2019) and later, and ICON 1.0 for TA and earlier. Get the date from its My Water Heater Information page, and call 800-334-3393 if you’re near that date.[1][2]

How I chose these tools and reference parts

Why trust my guidance

I write PlumbingPicks as a licensed journeyman plumber in Georgia. Every code, service action and part number here comes from Bradford White’s quick service guides, service manuals and parts list, named below, and product facts come from the makers’ listings and Fluke’s specifications.

How I choose

  • One tool or part per job the codes create: a meter for the two-flash and thermal switch tests, the valve kits and pilot Bradford White’s parts list names, and a pan and alarm for leaks.
  • Parts are genuine Bradford White part numbers, matched to the gas parts list; I left out listings that only say they fit Bradford White.
  • The meter had to read Bradford White’s 350 to 850 mV range at 1 mV or finer. I left out meters whose millivolt range I couldn’t confirm.
  • The three linked tools are new and sold by Amazon.com when checked. I keep the two valve kits and pilot assembly as unlinked service references, with no new parts recommendation.
  • The meter, valve kits, pilot, pan and alarm each answer a different code or job. They are separate tools and reference parts, rather than a packaged kit. The right part is the one your model and serial call for, so I compare published specs directly.
  • I checked CPSC recall records on November 15, 2026 for Bradford White, Fluke, Everflow and Resideo. I found no matching recall for these listed models; the Bradford White related result concerned Laars boilers.