I check the control version first: on gas ICON 1.0, two quick flashes with the burner heating are normal, while two fault flashes with the burner off indicate a weak pilot signal. If you smell gas, leave the building and call your gas supplier from outside.[2][4]
Tech’s thermopile meter: Fluke 117$207.01 at AmazonPrice as of Nov 22, 2026, 9:30 AM EST
Three tools and two reference parts, matched to the codes
Each one answers a specific code: a meter for the pilot tests, a valve kit and pilot for the parts Bradford White lists, and a pan and alarm for leaks. I keep the valve kits and pilot as unlinked service references; a qualified provider must confirm fit.
Your plumber or service tech needs a meter for the two-flash thermopile test, the thermal switch continuity test or an ICON E temperature sensor reading.
Skip it if
You only want to read the code and call a pro. Counting flashes needs no tools.
The tradeoff
I reserve live gas-appliance measurements for a qualified service provider. Counting the light pattern needs no meter.
Reference (not linked)
Bradford White 415-52907 kits
Reference only. I leave the service-part selection to a qualified provider using the heater model and serial number.
Reference (not linked)
Bradford White 233-47845-05
Reference only. I leave the service-part selection to a qualified provider using the heater model and serial number.
Your heater has no Bradford White accessory module, and you want a loud alarm on the floor beside the tank or in the pan.
Skip it if
You want the ICON valve itself to report a leak. That takes Bradford White’s own accessory module, which your plumber can confirm for your model.
The tradeoff
I use this as a separate audible water alarm. It does not add the Bradford White accessory module’s leak code.
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product.
On a phone, scroll this table sideways to read every column.
Fluke 117, DC V 6.000 V / 0.001 V, DC mV 600.0 mV / 0.1 mV, CAT III 600 V, 40.00 MΩ max, 9 V, 400 h typical[9]
Your plumber or service tech needs a meter for the two-flash thermopile test, the thermal switch continuity test or an ICON E temperature sensor reading.
You only want to read the code and call a pro. Counting flashes needs no tools.
Reference (not linked). Fits when a plumber has confirmed the valve is the fault, such as a seven-flash code that comes back after a reset or an eight-flash pilot that stays lit with the knob off, and your model and serial match one of these kits.
Your heater burns LP, its parts list calls for a White Rodgers valve, or nobody has tested the pilot, sensor and gas pressure yet.
Bradford White 233-47845-05 (reference)
233-47845-05, Kit 415-47845-05, Natural gas, Resideo valve models, Genuine OEM, Made in USA[7][10]
Reference (not linked). Fits when a two-flash code keeps coming back, the thermopile reads under 350 mV, and the resettable thermal switch tests closed, so Bradford White’s manual points to the pilot assembly.[4][7]
Your parts list shows a White Rodgers valve, the heater burns LP, or the thermal switch is open. Bradford White says an open switch is possibly from overheating, and the cause must be found first.
RWD21, Resideo, 1/16 in. water, Audible alarm, Reusable, Spot detector[10]
Your heater has no Bradford White accessory module, and you want a loud alarm on the floor beside the tank or in the pan.
You want the ICON valve itself to report a leak. That takes Bradford White’s own accessory module, which your plumber can confirm for your model.
Find the right ICON chart
I start with fuel type and the control generation. This chart selector cannot replace a test or an in-person check.
Which ICON control do you have?
Bradford White prints separate code charts for ICON 1.0, ICON 2.0 and the electric ICON E. The same flash count can mean different things, so start here.[1][2][5]
From Bradford White quick service guides 238-55593-00A (ICON 2.0) and 238-55592-00A (ICON 1.0) and quick start guide 238-54399-00B (ICON E).
Gas or electric comes first. A gas ICON heater has its status light on the gas valve at the bottom of the tank. An ICON E electric heater has an LED and a setpoint knob on its electronic control, and it uses colored flashes with a four-second pause.
On gas heaters, the generation follows the manufacture date. Bradford White’s quick guide labels ICON 2.0 for heaters with serial date code “TA” (January 2019) and later, and ICON 1.0 for “TA” and prior.[1][2]
To get the date, Bradford White’s FAQ points to its My Water Heater Information page, which reads it from the serial number on the rating plate. The quick guide also names the For The Pro contractor app.
If your serial is at or near January 2019, the quick guide says to call Bradford White technical support at 800-334-3393 to confirm the generation. A valve that’s been replaced may also differ from the original, since the 415-52907 kits are sold to replace earlier ICON valves.[1][2][7]
Every ICON gas code, side by side
Green rows are normal operation. Amber rows are faults to check. Grey cells mean that code isn’t on that generation’s chart.
From Bradford White quick service guides 238-55593-00A and 238-55592-00A. Fault codes repeat after a three-second pause.
The normal patterns are where owners get confused. On ICON 1.0, one flash and a three-second pause means the knob is in pilot or the water is hot. On ICON 2.0 the same state is one flash with a four-second pause.[1][2]
Heating looks different too. ICON 1.0 shows a strobe, two quick flashes and a three-second pause, while the burner runs. ICON 2.0 shows one flash every second. Neither is a fault.[1][2]
The trap is the ICON 1.0 strobe. Two quick flashes look a lot like the two-flash weak pilot code. Watch the timing: the strobe’s flashes come close together, and the burner should be lit. A true two-flash code comes with the main burner off.[2]
Codes 3, 7 and 8 exist only on ICON 1.0. If an ICON 2.0 valve seems to show seven flashes, count again through two full cycles, from one pause to the next.[1][2][4]
What to do first, and what to leave to a pro
Bradford White says the lights are there to help the professional plumber, and its service manual is written for qualified service providers only.
If you smell gas
Don’t try to light any appliance. Don’t touch any electrical switch or use any phone in the building. Call your gas supplier from a neighbor’s phone, or the fire department if you can’t reach them. That’s the instruction in Bradford White’s gas service manual.
If your sense of smell is weak
Bradford White warns that odorant fade can make gas harder to smell. If you’re unsure whether there’s gas, call your supplier from a neighbor’s phone, and ask your supplier or plumber about gas detectors.
What an owner can do
Read and record the code, relight the pilot by the label on the heater, and look for water around the base. A four-flash lockout reset comes from Bradford White’s service manual, which is for qualified service providers, so call one.
What belongs to a pro
Thermopile and sensor tests, gas pressure checks, thermal switch resets and part swaps. Bradford White’s manual says its service steps are “to be performed ONLY by qualified service providers.”
3 linked, 2 references, side by side
What each one does and which codes it serves. Scroll sideways on a phone.
On a phone, scroll this table sideways to read every column.
Bradford White’s quick service guide 238-55593-00A covers atmospheric and direct vent heaters with serial date code TA and later.[1]
On a phone, scroll this table sideways to read every column.
Light pattern
What it means
Bradford White’s service action
Possible parts
No light
No pilot; heater not running
Follow the lighting instructions on the heater
None
One flash, four-second pause
Knob in pilot, or water is up to temperature
None
None
One flash every second
Thermostat calling for heat
None
None
Solid on
Not an error: knob turned off, control shutting down
Wait until the light goes out before relighting
None
Two flashes, three-second pause
Weak pilot signal
Verify the pilot is lit; check thermopile voltage; check wire connections at the gas valve
Pilot assembly, then gas valve
Four flashes, three-second pause
High tank temperature
Check temp probe ohms; check if the tank is above setpoint; verify no heat migration in the plumbing
Gas valve cover with temp probe, then gas valve
Five flashes, three-second pause
Thermostat sensor fault
Check temp probe ohms and a tight connection; replace the gas valve
Gas valve cover with temp probe, then gas valve
Six flashes, three-second pause
Leak found by the accessory module
See the accessory module’s troubleshooting
Per the accessory module
From Bradford White quick service guide 238-55593-00A, page 1. Its general note also says to check all wire connections, gas inlet and manifold pressure, and grounding connections.[1]
The service manual’s ICON V2 chart adds color. Green is normal operation, yellow is low thermopile voltage on the two-flash code, and red marks the four- and five-flash faults. The solid light after shutoff is also red, but the chart says it isn’t an error.[4]
The four-flash row lists three checks before any part: the probe’s ohms, whether the tank really is above setpoint, and that there’s no heat migration in the plumbing system. Parts come after those checks.
ICON 1.0 codes: January 2019 and earlier
Quick service guide 238-55592-00A covers the earlier valve. It has three codes ICON 2.0 doesn’t: 3, 7 and 8.[1][2][4]
On a phone, scroll this table sideways to read every column.
Light pattern
What it means
Bradford White’s service action
Possible parts
No light
No pilot; heater not running
Follow the lighting instructions on the heater
None
One flash, three-second pause
Knob in pilot, or water is up to temperature
None
None
Strobe: two quick flashes, three-second pause
Thermostat calling for heat
None
None
Light on continuously
Knob turned to off
Wait for the light to go off before relighting
None
Two flashes, three-second pause
Weak pilot signal
Verify the pilot is lit; check thermopile voltage; check wire connections at the gas valve
Pilot assembly, then gas valve
Three flashes, three-second pause
No temperature rise in the expected time
Check temp probe ohms
Gas valve cover with temp probe
Four flashes, three-second pause
High tank temperature
Check temp probe ohms; check tank vs setpoint; verify no heat migration
Gas valve cover with temp probe, then gas valve
Five flashes, three-second pause
Thermostat sensor fault
Check temp probe ohms and a tight connection; replace the gas valve
Gas valve cover with temp probe
Six flashes, three-second pause
Leak found by the accessory module, if installed
See the accessory module’s troubleshooting
Per the accessory module
Seven flashes, three-second pause
Gas valve fault
Reset the gas valve; replace it if the code persists
Gas valve
Eight flashes, three-second pause
Pilot stays lit with the knob off
Check gas pressure; replace the gas valve
Gas valve
From Bradford White quick service guide 238-55592-00A. Bradford White’s atmospheric ICON sheet adds “verify water is not flowing” to the three-flash row.[2][3]
The service manual’s ICON V1 chart explains a few rows further. For three flashes it says the system resets on its own, and it names a thermal sensor out of calibration or a faulty gas control. Its fix is a new gas control.[4]
For seven flashes, the manual says the control needs a reset, or that it’s wet or physically damaged. For eight, it names a pilot valve stuck open. Shut the gas off at the heater’s manual valve and call a pro; a pilot that won’t go out with the knob off isn’t something to live with.
ICON E codes on electric heaters
The electric ICON E control uses green, amber and red flashes, each followed by a four-second off period. Quick start guide 238-54399-00B lists them.[5][6]
On a phone, scroll this table sideways to read every column.
Light pattern
What it means
Bradford White’s service action
Possible parts
No light
No power reaching the control
A pro turns the power off first, then checks the supply, the control’s connectors and the high limit wires; if it persists, the control module is replaced
Control module, if the fault persists
Amber-green, continuous
First 5 seconds after power on, or StartGuard self-check[5]
None; the control is working
None
Solid green
Thermostat satisfied
None
None
One green flash
Water is heating
None
None
Two amber flashes
Heating element fault
Power off, remove element wires, check ohms across the terminals
Heating element(s)
Three amber flashes
Power Switch Module (PSM) fault
Power off and replace the PSM
PSM
Four amber flashes
Temperature sensor fault
Power off, check wires and terminals; replace the upper sensor, then the PSM if it returns
Upper temperature sensor, then PSM
Five amber flashes
Controller fault
Replace the ICON E electronic control
ICON E control
Six amber flashes
Utility demand response event
Adjust the setpoint to override
None
Seven red flashes
High temperature
Check whether the high limit tripped; power off and check the PSM terminals for shorts
Upper sensor or PSM, as diagnosis shows
From Bradford White ICON E quick start guide 238-54399-00B (Rev. 11/22) and the ICON electric service manual 55036. The manual warns of high voltage exposure during voltage checks.[5][6]
StartGuard runs on a new heater and after the tank is drained to replace a burned-out element. Bradford White’s manual says it starts only if the setpoint knob is moved after power is applied, to a setting that calls for heat. It checks for a full tank and working elements in under 5 minutes.[6]
If amber-green lasts much longer than 5 minutes, the manual says there may be air in the tank or a damaged control. Otherwise the light changes to one green flash while heating.[6]
Six amber flashes isn’t a fault. The manual says it’s a Load Shed command from a utility program. Moving the setpoint knob away and back lets the heater run normally for 72 hours.[6]
Those utility programs usually require a setpoint of 140°F or higher, the manual says. Bradford White warns that 140°F water scalds in five seconds or less and strongly recommends an ASSE approved mixing valve at those settings.[6]
Solid green with no hot water has its own fix in the manual: move the knob around and back to the setpoint. That should start StartGuard, or one green flash if StartGuard already ran.
Two flashes: what your service tech will do
The pilot heats a thermopile, which powers the ICON valve with millivolts. Bradford White publishes the normal range.
From Bradford White gas service manual 238-51542-00, Service Procedure RG-II, and Fluke’s 117 specifications. Bar lengths are on a 1000 mV scale.
1
The tech holds the knob in pilot
With the pilot lit, Bradford White’s procedure has the tech turn the knob to pilot and keep it pressed.
2
The tech frees the red wire
Still pressing the knob, the tech removes the red (+) wire from the resettable thermal switch.
3
The tech measures to ground
The meter’s positive lead goes on the thermal switch terminal and the negative on an earth ground. On a meter whose mV range stops at 600, the tech uses the 6 V DC range.[4][9]
4
The tech reads the result
Between 350 and 850 mV is normal. The tech then reconnects the red wire to the gas control’s positive terminal, releases the knob and sets the temperature.[4]
5
Under 350 mV
The tech tests the resettable thermal switch next. If it’s closed, Bradford White recommends replacing the pilot assembly.
This is a live gas appliance with the pilot burning, so it’s a job for a qualified service provider. The steps above are Bradford White’s procedure RG-II as your tech does it. They’re here so you know what’s being checked and why, not for you to do yourself.
Don’t mix up the two kinds of pilot generator. Bradford White’s manual tests an old-style thermocouple on a mechanical White Rodgers valve at 20 to 30 mV, a fraction of an ICON thermopile’s output. A reading in that range on an ICON heater means something is wrong.[4]
Four flashes: resetting a high temperature lockout
Four flashes means the control saw the tank get too hot and shut down. Bradford White’s service manual gives the reset below for qualified service providers; it’s here so you know what the pro will do, not as an owner task.
1
Knob to off
Turn the gas control knob to the OFF position.
2
Wait five minutes
Wait a minimum of five minutes, Bradford White says.
3
Relight by the label
Follow the lighting instructions on the heater’s label, or in the installation and operation manual.
4
Set the temperature
Return the knob to your setpoint.
5
Watch the light
If four flashes come back, the manual moves on to testing the temperature sensor, which means taking the valve apart. That’s for a pro.
A lockout that keeps returning has a cause. The ICON 2.0 quick guide lists three checks: the temperature probe’s ohms, whether the tank really is above setpoint, and heat migration in the plumbing. The manual’s V1 chart adds a sensor out of calibration or a faulty control.[1][4]
The sensor test needs care. Bradford White says not to use standard multimeter probes on the sensor connector, since they damage it; it calls for pin-type probes or small wire pins. The tank temperature for that test comes from water drawn at the drain valve, measured with an accurate thermometer.
No light, and a pilot that won’t stay lit
No light means the valve has no power from the pilot. Relight by the label first. If the pilot won’t stay lit, the resettable thermal switch is next.
From Bradford White gas service manual 238-51542-00, resettable thermal switch color code reference. The switch opens at a set temperature that depends on the model.[4]
Bradford White’s flammable vapor resistant heaters have a calibrated thermal switch on the combustion chamber. The manual says it shuts down the pilot and burner if flammable vapors burn inside, or if lint, dust or oil clog the flame arrestor and starve the burner of air.
A qualified service provider can reset an open switch with its red button. The manual is firm that the overheating cause must be found before the heater goes back in service. Its listed causes are not enough combustion air, a weak or wrong switch, and a flammable vapor incident.
The air fixes, done by a qualified service provider, are clearing the jacket’s slot openings and cleaning the flame arrestor plate with a stiff brush or compressed air. After a flammable vapor incident, Bradford White’s answer is to replace the water heater. Our pilot light guide covers the other causes.
Mistakes people make with ICON lights
Six ways the light gets misread, and what Bradford White’s documents say instead.
Reading the wrong chart
Two quick flashes is normal heating on ICON 1.0 and close to the weak pilot code on either version. Check the serial date before you decide.[2]
Relighting while the light is solid
Both quick guides say to wait until the solid light goes out after the knob is turned off, then relight.
Pressing the thermal switch reset and walking away
Bradford White says the overheating cause must be found before the heater goes back in service.
Living with an eight-flash code
The pilot staying lit with the knob off points to a pilot valve stuck open. Shut off gas to the heater and call a pro.
Standard probes on the sensor plug
Bradford White says they damage the connector. The test calls for pin-type probes or small wire pins.
Expecting a leak code without the module
Six flashes on gas ICON heaters needs the accessory module. On ICON E, six amber flashes is a utility event, not a leak.
Questions people ask
Why is my Bradford White water heater’s green light blinking?
A slow single blink is normal. On ICON 2.0 it’s one flash with a four-second pause when the knob is in pilot or the water is hot, and one flash a second while heating. On ICON 1.0 it’s one flash with a three-second pause, or a quick two-flash strobe while heating.[1][2]
What do two flashes mean on a Bradford White water heater?
Two flashes and a three-second pause is a weak pilot signal on both ICON versions. Bradford White says to verify the pilot is lit, check thermopile voltage and check the wire connections at the gas valve. Normal thermopile output is 350 to 850 mV.[2][4]
What color should the status light be?
On the ICON V2 control in Bradford White’s service manual, green is normal, yellow is low thermopile voltage and red is a valve fault, except the solid red light after shutoff, which the chart says isn’t an error. On ICON E electric heaters, green is normal, amber is a fault or utility event, and seven red flashes is high temperature.[4][5]
How do I reset a Bradford White water heater?
For a four-flash high temperature lockout, Bradford White’s service manual, which is written for qualified service providers, has the technician turn the knob to OFF, wait at least five minutes, relight by the label and set the temperature. Have a qualified service provider do it, because a tank that overheated has a cause to find. If the code returns, the pro tests the temperature sensor.
What does seven flashes mean on a Bradford White?
On ICON 1.0 it’s a gas valve fault. Bradford White says to reset the gas valve, and to replace it if the code persists. ICON 2.0’s chart has no seven-flash code.[1][2]
What does eight flashes mean?
If you smell gas, leave and call the gas supplier or fire department from outside. On ICON 1.0, eight flashes means the pilot is staying lit with the knob turned off. Bradford White’s manual names a pilot valve stuck open; its fix is to check gas pressure and replace the gas valve. Shut the gas off at the heater’s valve and call a pro.[2][4]
Why is there no status light on my water heater?
On ICON E, no light means no power is reaching the control. On a gas ICON heater, the pilot is out; relight by the label. If it won’t stay lit, Bradford White’s manual says to replace the pilot assembly, then the gas control. A tripped resettable thermal switch also cuts the valve’s power, so a pro checks it too.
What does five flashes mean on a Bradford White?
On a gas ICON valve, it’s a thermostat sensor fault: Bradford White says to check the temperature probe’s ohms and its connection, then replace the gas valve. On ICON E, five amber flashes is a controller fault, and the fix is a new ICON E control.
How do I reset the flammable vapor sensor?
There is no owner reset for a vapor shutdown. The red button belongs to the resettable thermal switch, which trips on combustion-chamber overheating; it is not a vapor sensor. Bradford White says a qualified provider must find the overheating cause before the heater goes back in service, and after a flammable vapor incident it says to replace the heater, not reset it.
How do I know if I have ICON 1.0 or 2.0?
Bradford White labels ICON 2.0 for serial date code TA (January 2019) and later, and ICON 1.0 for TA and earlier. Get the date from its My Water Heater Information page, and call 800-334-3393 if you’re near that date.[1][2]
How I chose these tools and reference parts
Why trust my guidance
I write PlumbingPicks as a licensed journeyman plumber in Georgia. Every code, service action and part number here comes from Bradford White’s quick service guides, service manuals and parts list, named below, and product facts come from the makers’ listings and Fluke’s specifications.
How I choose
One tool or part per job the codes create: a meter for the two-flash and thermal switch tests, the valve kits and pilot Bradford White’s parts list names, and a pan and alarm for leaks.
Parts are genuine Bradford White part numbers, matched to the gas parts list; I left out listings that only say they fit Bradford White.
The meter had to read Bradford White’s 350 to 850 mV range at 1 mV or finer. I left out meters whose millivolt range I couldn’t confirm.
The three linked tools are new and sold by Amazon.com when checked. I keep the two valve kits and pilot assembly as unlinked service references, with no new parts recommendation.
The meter, valve kits, pilot, pan and alarm each answer a different code or job. They are separate tools and reference parts, rather than a packaged kit. The right part is the one your model and serial call for, so I compare published specs directly.
I checked CPSC recall records on November 15, 2026 for Bradford White, Fluke, Everflow and Resideo. I found no matching recall for these listed models; the Bradford White related result concerned Laars boilers.
Sources
Bradford White quick service guide 238-55593-00A, ICON 2.0, serial date code TA (Jan 2019) and later (codes, service actions, parts, generation note): bradfordwhite.com. Manufacturer document
Bradford White quick service guide 238-55592-00A, ICON 1.0, serial date code TA and prior (codes 1 to 8, service actions, parts): bradfordwhite.com. Manufacturer document
Bradford White atmospheric ICON quick service guides 238-55947 (three-flash “verify water is not flowing”): bradfordwhite.com. Source document
Bradford White residential gas service manual 238-51542-00 (qualified providers only, gas smell and odorant fade warnings, ICON V1 and V2 charts and LED colors, thermopile 350 to 850 mV, thermocouple 20 to 30 mV, thermal switch test and color codes, four-flash reset, pin probe caution, 14.0 in. W.C. maximum line pressure): bradfordwhite.com. Manufacturer document
Bradford White ICON E quick start guide 238-54399-00B, Rev. 11/22 (electric codes and service actions, StartGuard): bradfordwhite.com. Manufacturer document
Bradford White ICON electric service manual 55036 (StartGuard timing, demand response and 72-hour override, 140°F scald warning, sensor 1.2 to 33 kΩ, PSM 50 to 80 MΩ and 25 to 150 MΩ): bradfordwhite.com. Manufacturer document
Bradford White residential gas replacement parts list 238-46656-00R (415-52907 gas controls, 415-47845-05 pilot kit, 233-40248-05 pilot, model and serial required): bradfordwhite.com. Manufacturer document
Bradford White FAQ page (lights help the professional plumber, manufacture date from the serial): bradfordwhite.com. Source document
Fluke 117 product page and specifications (DC mV and DC V ranges and accuracy, ohms to 40 MΩ, continuity, CAT III 600 V, VoltAlert, battery life): fluke.com. Source document