Match your code to your model, then take the safe next step. Every code meaning here comes from a Rheem manual, and most codes end with a call to a qualified technician.
As an Amazon Associate I earn from qualifying purchases. Disclosure.
Chromex flush kit with vinegar. Product photo from Amazon.
Quick answer
Smell gas? Leave and call the gas supplier from a neighbor’s phone. Otherwise, find your code in Rheem’s chart: 11 and 12 mean gas supply, 90 and 99 the vent (-3 models), 1L scale, and 88 a flush or filter reminder.
Rheem’s owner charts are short. Most codes end with a call to a qualified technician; a few have owner steps. Start with the hazard checks below.
Gas odor: leave first
Rheem says not to light any appliance, touch an electrical switch or use any phone in the building. Call the gas supplier from a neighbor’s phone. If you cannot reach them, call the fire department. Do not reset the heater.
Fire, flood or vent damage
Rheem says to turn the heater off at the manual gas shutoff valve after a fire, flood or physical damage, and have it inspected before use. Do not run it if the vent shows signs of leaking exhaust.
Code missing from your chart
Rheem’s notice is plain: if the code is not in the chart, turn the heater off right away and call for service. Do not borrow a meaning from another brand or series.
11 or 12: gas supply
Rheem says to check that the gas shutoff valve is fully open, call the gas utility if service was interrupted, or refill an LP tank. Leave a valve closed if you do not know why it was shut.
90 or 99: air and vent
Clear a blocked air intake or vent opening you can reach from outside, keeping 12 in. of clearance at the intake. Disconnected vent pipes are technician work.
1L or 88: maintenance due
These point to lime buildup, a flush reminder or a water treatment filter. They are the codes where the parts on this page help.
Match the code style and model number to the right Rheem chart. Source: Rheem manuals AP22009, AP21820, AP18000-2, SVC820 and AP23209.
Five parts for the codes an owner can act on
Each pick matches a maintenance step Rheem names, so they aren’t scored against each other. None of them fixes a gas, vent, sensor or circuit fault.
Product photo from Amazon.
Chromex flush kit with vinegar
Best for Rheem’s vinegar flush
Key specs
1/6 HP pump, 6‑gallon bucket, two 6 ft hoses, NSF/ANSI/CAN 60 vinegar
Pick it if
Your heater shows 1L or 88, or the flush is due, and it has two service valves with drain ports.
Skip it if
The code is 11, 12, 14, 31, 33, 61, 90 or 99, or the heater has no service valves yet.
The code on your display decides the part. Read the fit lines before you choose.
Rheem’s technician pocket manual, SVC820, lays out a vinegar flush. A pump sits in a 5‑gallon bucket, hoses go on the heater’s service valves, and 2 gallons of virgin food-grade white vinegar circulate for 45 to 60 minutes. This Chromex kit is the closest match I found, because it ships with vinegar instead of a branded descaler.
Chromex lists a 6‑gallon bucket with a lid, a 1/6 HP submersible pump, a pump grate and two 6 ft PVC-coated hoses. The vinegar is a concentrate certified to NSF/ANSI/CAN 60. Chromex says to add 3 parts water, and the listing title says the concentrate makes 4 gallons.
Timing is where the listing and Rheem part ways. Chromex says its flush takes 30 minutes or less. Rheem says to circulate for 45 to 60 minutes, then drain, clean the inlet filter and run cold water through the heater for about 5 minutes. Use Rheem’s times; the table below shows both.
Before a hose goes on, Rheem has the gas turned off for the whole job and the cold and hot water valves closed. The remote goes off for 10 seconds, back on for 10 seconds, and then the heater is unplugged. Read the vinegar label for its handling steps; gloves and eye protection are a sensible minimum.
The bucket clears Rheem’s 5‑gallon size, which matters because the hot-side hose returns solution to the same bucket the pump draws from. The lid helps when you carry used solution away. Set the pump on the bottom of the bucket, as Rheem’s steps describe, so it does not pull air.
This kit needs service valves on the heater. If yours has none, the Rheem valve kit below has to be installed first, and that is plumber work. Codes 1L, 88 and IKONIC A018 make a flush relevant. Codes 11, 12, 14, 90 and 99 do not point to scale, so a flush kit is the wrong first step.
My call: this is the kit for a Rheem or Ruud tankless heater when you want to follow Rheem’s vinegar method without mixing a branded chemical. If you prefer Rheem’s exact wording, use 2 gallons of plain food-grade white vinegar in the same bucket. Either way, keep circulation at 45 minutes or more.
Superior Pump 91660 for braided hoses
Superior Pump’s 91660 kit is the pick when you care most about the pump and hoses. Superior’s own product page lists a 1/6 HP, 115 V pump rated at 1,920 gallons per hour with an 8 ft cord. The Amazon listing adds two 6 ft stainless steel hoses with 3/4 in. garden hose threads.
Two parts of the kit do not match Rheem’s method. The pail holds 3.5 gallons, while Rheem’s pocket manual calls for a 5‑gallon bucket. The kit also includes a 7 oz descaler powder, and Rheem’s procedure names white vinegar instead. The conflict table below lists both, and Rheem’s figure is the one to follow.
That means using the kit a little differently. Set the pump in your own 5‑gallon bucket and fill it with 2 gallons of food-grade white vinegar as Rheem describes. Keep the powder for a heater whose maker approves it, or ask Rheem’s service line at 1-866-720-2076 before using it on your unit.
Stainless braided hoses help at a heater mounted close to a wall, where a vinyl hose can fold at the valve. Check the thread on your service ports before starting. A mismatch shows up as a leak once the pump is running, and the solution coming back from the heater can be warm.
The prep is the same as for any Rheem flush. Gas off for the whole job, cold and hot water valves closed, and the heater unplugged after Rheem’s remote off and on sequence. Open the service port caps slowly over the bucket, because a little trapped water will come out first.
The listing gives the pump a 20 ft lift, far more than a flush at the heater needs. What matters more is that the pump sits flat on the bucket floor and stays covered by solution. If the pump starts to gurgle, the solution level is too low for it.
My call: choose the Superior kit if braided hoses suit your valve layout, and plan on your own 5‑gallon bucket and vinegar. If you want the full set of what Rheem’s steps call for in one box, the Chromex kit is closer. Neither kit fixes a fault code other than a scale reminder.
Rheem RTG20220AB when there are no service valves
Rheem’s use and care manual says an isolator valve kit is highly recommended, because flushing needs a way to shut off the heater’s water and open a port for hoses. Rheem’s use and care manuals name RTG20220AB as their tankless isolation valve. This Amazon listing is that Rheem part number, in 3/4 in. brass.
Look under your heater before choosing a flush kit. Two valves with handles and small drain caps on the cold and hot lines mean the heater already has them. If the lines run straight into the heater with no valves, no flush kit can connect, and a flush cannot be done the way Rheem describes.
Rheem’s parts catalog says the kit includes a pressure relief valve. Rheem’s manual says to check the relief valve yearly, never plug it, and call the water supplier or a plumber if it discharges now and then. A relief valve that drips steadily is a separate problem from any code on the display.
Installing this kit means opening the water lines at the heater, close to the gas line and the power cord. That is a job for a licensed plumber. Before work starts, the gas is shut off at the heater’s manual gas valve, the heater is unplugged, and the water is shut off and drained.
Once the valves are in, each later flush is simpler. You close the two main valves, take the caps off the service ports and connect the hoses. Rheem’s easy installation guide talks about flushing every year to a year and a half, and the valves make that routine instead of a plumbing job.
I chose the Rheem part number over generic valve kits because Rheem names it directly. A generic kit can work, but you would have to match the pipe size, connection type and relief valve setup yourself. The plumber installing it can confirm the fit to your existing lines before cutting anything.
My call: this is the first fix for a Rheem tankless heater with no service valves. Checking takes a flashlight and a minute, and it decides whether any flush kit on this page will work at your house. If the valves are already there, skip this part and go straight to the flush.
Rheem RTG20252 for code 88 with AllClear
Rheem’s code 88 is a reminder, not a fault. The RTGH chart reads it as a reminder to flush the heat exchanger or replace the water treatment filter. On a heater fitted with Rheem’s AllClear kit, part RTG20251, the cartridge inside is RTG20252. This listing is that cartridge.
Only choose it if you have the housing. Look for a filter canister on the cold water line feeding the heater, with an AllClear or RTG20251 label. With no canister, the cartridge has nothing to fit into. In that case, code 88 points to a flush, and the kits above apply instead.
Code 88 only appears when the maintenance notice is switched on. Rheem ships it set to off. It can be set to 500, 750 or 1,000 hours, and that number decides how often the reminder fires. Check the setting before deciding a cartridge wore out early.
Swapping the cartridge is water work, but the line is under pressure. Turn the heater off, close the cold water supply, and open a hot tap to relieve pressure before opening the housing. Rheem’s cartridge instructions were not online when I looked, so follow the sheet that comes with the cartridge.
Clearing 88 has its own steps in Rheem’s RTG manual. With the remote on, close the gas and water valves, press DOWN to the lowest temperature, then hold DOWN and UP together for 5 to 10 seconds. Reopen the valves. If 88 stays, repeat the steps once.
The AllClear system targets scale. Rheem’s water quality table sets total hardness at up to 200 mg/L and total dissolved solids at up to 500 mg/L. Rheem’s warranty excludes damage caused by water quality, so a working treatment filter matters more than usual in a hard water area.
My call: replace the cartridge when 88 shows on a heater with an AllClear housing, then flush as well if the heater’s hours say a flush is due. A fresh cartridge slows new scale. It does not remove scale already stuck inside the heat exchanger, and a 1L code means that scale is there now.
CondensateRx for condensing RTGH drains
Only condensing heaters need this. Those are the RTGH models and the IKONIC units, which make acidic water as they run. Rheem’s RTGH manual recommends an external neutralizer, because untreated condensate corrodes metal drains and fittings. Noncondensing RTG models have no condensate drain, so skip this part if your model lacks the H.
Code 29 on an RTGH display reads as a clogged neutralizer in the owner’s chart. Rheem’s technician pocket manual splits 29 into a drain that is not flowing and a heat exchanger that stayed too cold. Codes 92 and 93 there track neutralizer life, and IKONIC’s A029 means the condensate trap reads full.
American Valve’s CondensateRx is a sealed tube of neutralizing media with 1/2 in. female pipe thread ends and adapters for 1/2 in. barb and 3/4 in. PVC. The listing rates it for heaters up to 220,000 Btu/h and 3.8 gallons of condensate an hour, with condensate no hotter than 100°F.
That rating covers the largest RTGH model, which Rheem’s spec sheet lists at 199,900 Btu/h. Rheem’s easy installation guide names its own neutralizer parts, SP12151 and RXGY-A01. CondensateRx is a third-party option, so check its rating against your heater’s rating label before choosing it.
Rheem’s drain rules still apply around the neutralizer. The line slopes down, ends open to the air, is not tied straight into a sewer pipe, and stays protected from freezing. Turn the heater off before opening the condensate line. Condensate is acidic, so wear gloves and eye protection.
When 29 comes from a blocked line, a new neutralizer will not fix it. Rheem’s pocket manual lists a pinched line, a blockage and an unneeded P-trap as causes, and on a new install, a protection plug left in the drain port. If the line is clear and 29 returns, call a technician.
My call: inspect the neutralizer every year, as Rheem’s RTGH manual says, and replace it when the media is used up. If your heater has shown 92, replace it soon. In Rheem’s pocket manual, 93 means the heater will not run until the neutralizer is replaced and the code is cleared.
Compare the five parts
Each part answers a different code or setup question. Start from the code, then the fit column.
Where a listing and Rheem disagree, the table below uses Rheem’s figure. Rheem’s manuals do not name either flush kit by brand.
Where claims differ
Listing says
Rheem says
Use this
Chromex circulation time
30 minutes or less
Circulate 45 to 60 minutes (SVC820)
Rheem’s 45 to 60 minutes
Chromex solution
NSF 60 vinegar concentrate, 1 part to 3 parts water
2 gallons of virgin food-grade white vinegar
Plain food-grade white vinegar meets Rheem’s wording exactly
Superior pail size
3.5‑gallon pail
5‑gallon bucket
Your own 5‑gallon bucket
Superior cleaner
7 oz descaler powder
White vinegar
Vinegar, unless Rheem approves the powder for your unit
Which Rheem chart matches your heater
Rheem’s two-character codes mean slightly different things across generations. Read the model on the rating label first.
Model on the label
Type
Owner code chart
Codes it adds
RTG-70, 84 or 95DVL-3 (and Ruud equivalents)
Noncondensing
AP22009 Rev 04, p.77
None beyond the core list
RTGH-68, 84, 90 or 95DVL-3 (and Ruud equivalents)
Condensing
AP21820 Rev 04, p.75
29 neutralizer, 71 solenoid circuit
Older noncondensing units, 150,000 to 199,900 Btu/h
Noncondensing
AP18000-2 Rev 03, p.26
05, 13, 15 and 65
IKONIC RTGH-S, RTGH-SR, CRTGH, RUTGH
Condensing, LCD screen
AP23209 Rev 03 alarm list
A and T codes, three digits
Ruud tankless heaters share Rheem’s manuals. AP22009 and AP21820 both cover Rheem and Ruud models, and the IKONIC service manual includes RUTGH units. A Ruud owner can use the same chart as the matching Rheem model. If your label shows a model not listed here, ask Rheem’s service department for the right manual.
Owner chart codes for RTG and RTGH -3 models
These are Rheem’s own words, condensed. “Technician” means Rheem’s chart directs you to a qualified service technician.
Code
Rheem’s cause
Rheem’s owner step
Models
1L
Lime deposits building up in the heater
Technician; flush per the steps below
RTG and RTGH
11
Gas shutoff valve not fully open
Check the valve and open it fully
RTG and RTGH
12
Gas service interrupted, or LP running low
Call the gas utility, or refill the LP tank
RTG and RTGH
14
Heater overheating
Technician
RTG and RTGH
29
Neutralizer clogged
Technician
RTGH only
31
Faulty inlet thermistor
Technician
RTG and RTGH
33
Faulty outlet thermistor
Technician
RTG and RTGH
61
Faulty blower motor
Technician
RTG and RTGH
66
Faulty bypass motor
Technician
RTG and RTGH
71
Solenoid valve circuit failure
Technician
RTGH only
88
Reminder to flush or replace the water treatment filter
Chart says technician; after the flush or cartridge change, clear it with the manual’s steps
RTG and RTGH
90 or 99
Air intake or vent opening blocked, or vent pipes not connected
Remove a blockage; disconnected pipes need a technician
RTG and RTGH
P1
Not enough water flow to run the heater
Open the fixture further
RTG and RTGH
Codes on older Rheem and Ruud models
Heaters built before the -3 series use manual AP18000-2. Some numbers differ, so check your label before using this table.
Code
Rheem’s cause
Owner step
05
Vent blocked or not connected
Clear a reachable blockage; otherwise technician
11
Gas shutoff valve not fully open
Open the valve fully
12
Gas service interrupted or LP low
Call the gas utility, or refill the LP tank
13
Code stays after the restart steps
Technician
14
Overheating
Technician
15
Heat exchanger too hot; vent check needed
Technician
31 and 33
Inlet or outlet thermistor
Technician
61 or 99
Blower fault
Technician
65
Water flow solenoid
Technician
1L
Lime buildup
Technician; flush
P1
Not enough flow
Open the fixture further
88
Maintenance reminder
Chart says technician; flush, then clear with the manual’s steps
Notice that 99 means a blower fault on these older units but a vent blockage on the -3 series. That one difference is the reason to read the label first. A wrong chart can send you to the vent when the blower is the problem, or the other way round.
Codes from Rheem’s technician pocket manual
Rheem’s SVC820 pocket manual covers mid and high efficiency units and lists codes the owner charts leave out. These are for diagnosis by a qualified technician; I list them so you can describe the fault on the phone.
Code
What the pocket manual says
Who handles it
03
Communication fault between manifolded units
Technician
05
Improper combustion, indoor units
Technician
10
Heater run before venting was installed, or blower not moving enough air; hard lockout
Technician
11
No flame: check gas supply and venting
Owner checks gas valve; then technician
12
Flame lost during operation
Owner checks gas supply; then technician
13
Poor combustion, indoor units; locks out after 5 shutdowns in 4 hours
Technician
14
Overheat limit tripped
Technician
15
Hot water or heat exchanger at 207°F for more than 15 seconds
Technician
16
Outlet water above the set point
Technician
24
Control buttons held more than 20 seconds
Owner: release buttons and run the heater
29
Condensate not draining, or heat exchanger too cold for over 3 minutes
Owner checks the drain line; then technician
31 to 35
Thermistor faults
Technician
51 and 80
Flame sensed after shutoff
Technician
52
Gas valve regulator (PGFR) fault
Technician
61 and 79
Blower faults
Technician
65
Water volume valve fault
Technician
66
Bypass valve fault
Technician
71
Gas valve inlet solenoid fault
Technician
72
Flame sensed before the igniter fired
Technician
76
Remote control communication fault
Technician
82
Program chip fault
Technician
90 and 99
Vent blockage before ignition (90) or after shutdown (99); 99 is a hard lockout
Owner clears reachable blockage; then technician
92
Neutralizer needs replacing soon
Owner or technician replaces neutralizer
93
Heater stopped until the neutralizer is replaced
Replace neutralizer, then clear the code
The pocket manual says hard lockouts 10, 13 and 99 are reset on the control board, behind the front cover. That is technician work, because it means opening the cabinet with the power and gas connected. The owner chart never asks you to remove the cover, and Rheem warns to cut power first because of shock risk.
IKONIC alarm codes
IKONIC heaters show a letter and three digits on an LCD screen. A codes are alarms that stop the heater; T codes are notices.
Code
Meaning in Rheem’s IKONIC manual
Next step
A011
No flame after 10 ignition attempts
Check gas valve is open; then technician
A012
Flame lost 15 times in a row
Technician
A014
Overheat limit (gas or venting)
Technician
A018
Lime buildup
Flush with Flush Heater set to YES, then back to NO, then clear
A029
Condensate trap reads full or cannot be read
Check the drain line; then technician
A031, A032, A033, A036
Inlet, heat exchanger, outlet or exhaust thermistor
Technician
A035
Thermistor connection fault
Technician
A055
Gas motor (venturi butterfly) fault
Technician
A061
Fan speed fault
Technician
A063
Recirculation pump fault
Technician
A065, A066
Water volume valve or bypass valve fault
Technician
A070, A071, A072
Control board, gas and air ratio valve, or flame before ignition
Technician
A082
Gas chip fault
Technician
A090
Vent blockage; check venting, air filter and gas pressure
Clear reachable blockage; then technician
A200, A2##
Screen communication, or a fault on manifold unit ##
Technician
T110
WiFi chip notice
Technician if it persists
T111
Service reminder; heater will eventually stop
Flush, then clear
T113
Flow under 0.4 GPM
Open the fixture further
T115
Pump schedule set but no clock time
Set the clock
T116
Fault on a manifolded unit
Technician
The IKONIC screen keeps up to 4 current alarms and 6 in history. To clear current alarms, open SERVICE, choose Current Alarms, then Clear Alarms, and press ENTER. Rheem sets the IKONIC service reminder at 500 hours from the factory, with 750 and 1,000 hours available, and says changing it is not recommended.
How to reset a Rheem tankless heater
Rheem’s owner reset is a power cycle, not a button. Write the code down first, because it may clear from the screen.
1
Check for hazards first
With a gas odor, leave and follow the gas steps at the top of this page. After fire, flood or vent damage, shut the manual gas valve and have the heater inspected.
2
Write down the code and model
Note the full code and the model on the rating label. A photo of both is enough.
3
Turn off and wait
Turn off the hot water faucet and the heater. Wait about 5 minutes, turn the heater back on, open a hot faucet and recheck the display.
4
Unplug for 30 seconds
If the code stays, turn off the faucet and heater, unplug the heater for about 30 seconds and plug it back in. Follow the chart step for your code, then restart and recheck.
5
Call for service
If the code is still showing, note it and call your installer, a plumbing contractor or Rheem’s national service line at 1-866-720-2076.
Code 24 is the odd one out. Rheem’s pocket manual says it appears when the control buttons are held down for more than 20 seconds. Release the buttons and run the heater. If 24 comes back with nobody pressing anything, a stuck button or remote is the likely suspect, and that needs a technician.
On some models a 1L reminder resets when MIN and MAX are held together for 10 seconds, per the pocket manual. Clearing 1L without flushing only hides the reminder. Scale stays in the heat exchanger and can lead to overheating codes like 14 later.
Codes 11 and 12 for the gas supply
These are the two codes Rheem lets an owner check without a technician, within limits.
Code 11 means no flame. Rheem’s owner step is to check that the gas shutoff valve at the heater is fully open. The handle runs in line with the pipe when open. If someone closed it on purpose, find out why before opening it. A valve shut after a leak repair should stay shut until that work is checked.
Code 12 means the flame went out. On natural gas, Rheem says to call the gas utility if service was interrupted. On propane, refill or replace the tank. If other gas appliances in the house work and the tank is full, the fault is in the heater or its gas line, and that is technician work.
Gas type
Inlet pressure a technician checks
Owner check
Natural gas
4.0 to 10.5 in. w.c.
Do other gas appliances work? Was service interrupted?
Propane (LP)
8.0 to 13.0 in. w.c.
Is the tank level low? Is the tank valve open?
Measuring gas pressure means opening a test port on a live gas line. Leave it to a licensed professional. Low pressure at the heater can come from an undersized line or a regulator problem, and both need a gas fitter, not a reset.
Codes 90, 99 and 05 for air and vent
Rheem treats the air intake and vent as an owner check only from the outside.
On the -3 series, 90 and 99 mean the air intake or vent exhaust may be blocked, or the vent pipes may not be connected. You can clear leaves, snow, a nest or a cover from an outside termination you can reach. Rheem asks for 12 in. of clearance at the air intake.
Do not take apart vent joints or reseat pipes. A disconnected vent can leak exhaust into the house, which is a carbon monoxide risk. Rheem says not to run the heater if the vent shows signs of leaking exhaust. If clearing a blockage does not stop 90 or 99, call a technician.
Every home with a gas water heater needs working carbon monoxide alarms. If one sounds, get everyone outside and call 911 from there. Do not go back in to reset the heater.
Code 29 and the condensate drain
Only RTGH and IKONIC heaters make condensate. On those, a drain problem is the most common owner-fixable cause of 29.
Rheem drain rule
Why it matters
PVC, CPVC or flexible tube line
Condensate is acidic and corrodes metal
Line slopes down all the way
A sag holds water and backs up the trap
End is open to the air, not tied straight to a sewer pipe
Prevents sewer gas and siphoning
Protected from freezing
A frozen section blocks the drain and triggers 29
External neutralizer recommended
Treats acidic condensate before the drain
Turn the heater off before you touch the condensate line, and wear gloves; the water is acidic. Look for a kink, a sag, a frozen run outside or a P-trap someone added. The pocket manual lists each as a cause. If the line is clear and 29 returns, call a technician.
P1, T113 and no code for water flow
Some problems show a flow code. Others show nothing.
P1 on the -3 series means there is not enough water flow to run the heater. Rheem’s fix is to open the fixture further. The pocket manual puts the activation flow at 0.4 GPM, and IKONIC flags the same threshold as T113. A clogged faucet aerator or a dirty inlet filter can drop flow below that.
Flow figure
Value in Rheem’s pocket manual
What it means at the tap
Activation flow
0.4 GPM
Below this, the burner does not light
Extinction flow
0.25 GPM
Below this, a running burner shuts off
IKONIC T113
Flow under 0.4 GPM
Same threshold, shown as a notice
Rheem tells owners to clean the cold inlet water filter monthly. Turn off and unplug the heater, shut the water, drain, then unscrew the filter from the cold inlet. Rinse it with a soft brush and refit it snug, without tapping, forcing or overtightening it. My faucet aerator guide covers the fixture end.
Warm or cold water with no code can come from a crossover, where hot and cold mix at a faulty fixture. Rheem’s pocket manual describes a test: close the heater’s hot outlet valve and open only the hot side at each fixture. Water that still flows points to a crossover at that fixture. A plumber can trace and repair it.
How Rheem’s flush works
This is the pocket manual’s vinegar procedure, in plain words. If your heater has no service valves, stop here and have them installed first.
1
Shut gas and water
Turn the gas off at the heater’s manual valve and keep it off for the whole job. Close the cold and hot water valves.
2
Cut power
Turn the remote off for 10 seconds, on for 10 seconds, then unplug the heater.
3
Connect the hoses
Hang hoses from the service ports into a 5‑gallon bucket. Run the cold side hose to the pump outlet and set the pump on the bucket floor.
4
Circulate vinegar
Add 2 gallons of food-grade white vinegar, open the service ports and circulate for 45 to 60 minutes.
5
Drain and rinse
Drain the vinegar into the bucket. Move the hot-side hose to a second bucket or a drain, close the cold-side service port and remove that hose, then clean the inlet filter. Open only the cold water supply and run water through for about 5 minutes. Keep the hot supply valve closed.
6
Restore
Close the service ports, open the main valves, purge air at a tub faucet, then restore power and gas and test.
Display setting
Code 88 shows after
Rheem’s note
OF
Never
Factory setting; the notice is optional
50
500 hours of combustion
Shortest interval
75
750 hours of combustion
Middle interval
100
1,000 hours of combustion
Longest interval
To change the RTG setting, Rheem’s steps start with the remote off and the gas and water valves closed. Hold the up and down arrows on the heater’s built-in display until 1Y shows, step to 8A, hold power for 1 second, choose the value, then reopen the valves.
Rheem’s easy installation guide talks about flushing every year to a year and a half.
Vinegar is mild, but it still splashes. Keep the bucket on a towel, wear eye protection, and keep the area ventilated. My tankless descaling guide walks through the same job with more photos, and my flush kit comparison covers other kit types.
Water quality limits in Rheem’s manuals
Rheem’s warranty excludes damage from water outside these limits. A water test tells you whether scale codes will keep coming back.
Measure
Rheem limit
pH
6.5 to 8.5
Total hardness
Up to 200 mg/L
Total dissolved solids
Up to 500 mg/L
Chlorides
Up to 250 mg/L
Iron
Up to 0.3 mg/L
Manganese
Up to 0.05 mg/L
Copper
Up to 1.0 mg/L
Zinc
Up to 5 mg/L
If your water tests above 200 mg/L hardness, plan on more frequent flushing and set the maintenance notice to 500 hours. Rheem sells a scale prevention device (RTG20246 or RTG20247) and the AllClear kit (RTG20251) for this. My hard water guide explains what the numbers mean at the tap.
When to call a pro
Most Rheem codes end here. These are the clear lines.
Gas, combustion or overheating
Codes 10, 13, 14, 15, 16, 51, 52, 71, 72 and 80 involve the burner, gas valve or flame. Do not open the cabinet.
Sensors, motors and boards
Thermistor codes 31 to 35, blower codes 61 and 79, valve codes 65 and 66, and board codes 76 and 82 need a technician with Rheem’s service manual.
Vent faults that return
If 90 or 99 comes back after you clear a reachable blockage, the vent needs inspection. Do not reseat vent pipes yourself.
Owner tasks Rheem allows
Open a closed gas valve after checking why, refill LP, clear an outside blockage, clean the inlet filter, flush through installed service valves, and replace a filter cartridge or neutralizer.
Questions about Rheem tankless codes
How do I check the error code on my Rheem tankless water heater?
The code shows on the remote control display, or on the LCD screen of an IKONIC unit. Two characters, like 11 or 1L, belong to the RTG and RTGH charts. A letter and three digits, like A011, belong to IKONIC. Note your model from the rating label on the side of the heater.
How do I reset my Rheem tankless water heater?
Turn off the hot faucet and the heater, wait about 5 minutes, then turn it back on. If the code stays, unplug the heater for about 30 seconds, follow the chart step and restart. If it is still there, note the code and call for service.
What does error code 11 mean on a Rheem tankless?
No flame. Rheem’s owner step is to check that the gas shutoff valve is fully open. If it is open and other gas appliances work, a technician needs to check the gas line and ignition.
What does error code 12 mean?
The flame went out during use. On natural gas, check whether service was interrupted; on propane, check the tank level. If gas supply is fine, call a technician.
What does code 29 mean on a Rheem RTGH?
Rheem’s owner chart says the neutralizer is clogged. The pocket manual adds a blocked or pinched condensate drain and a heat exchanger that stayed too cold. Check the drain line with the heater off, then call a technician if 29 returns.
What does 1L mean?
Lime buildup in the heat exchanger. Rheem’s chart directs you to a qualified technician, and the fix is a flush through the service valves. Clearing the code without flushing only hides the reminder.
What is code 24 on a Rheem tankless?
Rheem’s pocket manual says 24 appears when control buttons are held for more than 20 seconds. Release them and run the heater. If it returns with nobody pressing buttons, call a technician.
What does 88 mean?
A maintenance reminder to flush the heat exchanger or replace the water treatment filter. It only shows if the maintenance notice was set to 500, 750 or 1,000 hours. Flush or replace the cartridge, then clear it with Rheem’s DOWN and UP button steps.
What are the most common tankless water heater error codes?
On Rheem units, the codes with owner steps are gas supply codes 11 and 12, scale reminders 1L and 88, vent codes 90 and 99, and P1 for low flow. My Rinnai code guide and Navien code guide cover the other two big brands.
Do Ruud tankless heaters use the same codes?
Yes for the models covered here. Rheem’s AP22009 and AP21820 manuals cover both Rheem and Ruud models, and the IKONIC manual includes RUTGH units. Match your model to the right chart first.
Can I flush a Rheem tankless with vinegar?
Yes. Rheem’s technician pocket manual describes a flush with 2 gallons of virgin food-grade white vinegar circulated for 45 to 60 minutes, followed by a cold water rinse of about 5 minutes. The heater needs service valves to connect the hoses.
Why trust this reference, and how I chose parts
Why trust me
I’m a licensed journeyman plumber in Georgia, and I’m responsible for this reference. In my 7 years of experience, these are the products I’d install. Every code meaning comes from a Rheem manual named below. Where Rheem’s manuals give no owner step, this page says to call a technician rather than guess.
How I pick
I matched each part to a maintenance step Rheem names, then checked that each Amazon listing is the listed brand’s own product, sold new. Where a listing disagrees with Rheem, I follow Rheem.
The five parts do different jobs, so I don’t score them against each other. CPSC lists no recall for Rheem or Ruud tankless heaters, Chromex, Superior Pump or American Valve.
Evidence check
Rule applied
Code meaning
Rheem manuals only, matched to model family; no forum definitions.
Owner versus technician
Owner steps only where Rheem’s owner chart gives one.
Offer check
New condition, winning offer, plain In Stock, brand confirmed in the listing details.
Recall check
CPSC search for Rheem, Ruud and each pick’s brand; no tankless recalls found.
CPSC recall search for Rheem, Ruud, Chromex, Superior Pump and American Valve, Nov 10, 2026: the Rheem recalls on file (16177, 09104, 99061, 98072 and 80042) cover tank water heaters, furnaces and vent pipes, not tankless models; none for the others.