The short answer
EPDM is the factory-default ProPress seal and the only one Viega’s manual permits for drinking water: Viega 2989 on 1/2-inch fittings. For approved FKM service, use 17778 (3/4-inch) or 17823 (2-inch), before pressing. A seal swap never approves gas service. [1] [2] [3] [5] [9] [10]

Replacement seals for unpressed fittings
Each seal fits one ProPress size and one kind of service, so your line decides, not a score. Only the EPDM ring is permitted for drinking water, and none of them repairs a joint that’s already pressed.13

Viega 2989 EPDM seal for 1/2-inch ProPress

Viega 17778 FKM seal for 3/4-inch ProPress

Viega 17823 FKM seal for 2-inch ProPress
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product.
| Seal | Key specs | Pick it if | Skip it if |
|---|---|---|---|
| Viega 2989 EPDM seal for 1/2-inch ProPress | Model 2989, Part 78242, 1/2-inch fitting size, EPDM, Shiny black, Seal range: 0 to 250°F [1] [9] [10] | A 1/2-inch Viega ProPress fitting on a drinking-water or standard heating line lost or nicked its ring before pressing. [1] | The specification calls for FKM, the fitting is another size, or the joint has already been pressed. |
| Viega 17778 FKM seal for 3/4-inch ProPress | Model 2986, Part 17778, 3/4-inch fitting size, FKM, Dull black, Seal range: 14 to 284°F [1] [5] | The approved application specifies FKM for an unpressed 3/4-inch Viega ProPress CTS fitting, and the listing’s pack quantity suits the job. [1] | The line carries drinking water, the fitting is a different size, or the joint has already been pressed. |
| Viega 17823 FKM seal for 2-inch ProPress | Model 2986, Part 17823, 2-inch fitting size, FKM, Dull black, Seal range: 14 to 284°F [1] [5] | The application chart and specification permit FKM in an unpressed 2-inch Viega ProPress CTS fitting, with package identity confirmed. [1] | The fitting is 2-1/2-inch XL, the line carries drinking water, or you need to repair a permanent pressed connection. [1] |
Viega 2989 EPDM for 1/2-inch water lines
Fitting size and the approved service decide which ring goes in, so none of the three is scored.
Model 2989 is Viega’s EPDM sealing element, the shiny-black ring ProPress copper fittings ship with. The listing names Viega, model 2989, EPDM and the 1/2-inch size. Viega’s catalog maps that size to part 78242; the title doesn’t print the part number, so match it on the package. [1] [3] [9] [10]
EPDM is the ring to keep on a drinking-water line. Viega’s ProPress manual permits only EPDM for potable installations, so a domestic hot or cold fitting that loses its ring before pressing gets this element back, not FKM.13
Viega’s seals sheet gives EPDM a 0 to 250°F material range. That covers domestic hot water and most hydronic heating. Viega suggests considering FKM when heating media run at 200°F or above continuously; that advice is for closed heating loops, never the drinking-water side. [1] [2] [3]
Where it does well
- The only seal Viega’s manual permits for drinking water
- The factory-default ProPress seal, shiny black
- Listing names Viega model 2989, EPDM and 1/2 inch
What to watch
- Listing omits part 78242 and the pack count
- Material range tops out at 250°F, below FKM’s 284°F
- New stock from ZenSupplyInc at my current check
Half-inch sits inside Viega’s small-fitting procedure for 1/2 through 2-inch fittings. Lift the old ring out with a blunt object, never a sharp metal pick, and seat the new one fully in the bead. Check the metal seat for scratches and debris while the ring is out. [1] [4]
The listing does not state a pack count. ZenSupplyInc had new stock at my November 15 check. If you need rings for several fittings, confirm the quantity on the order page before you count on it. [1]
My call: if a 1/2-inch ProPress fitting on a water line has a missing or nicked ring before pressing, this is the replacement. A pressed joint can’t be fixed by swapping rings, and no seal swap approves gas service. [1] [2] [4]
Viega 17778 FKM for 3/4-inch fittings
Viega identifies part 17778 as the dull-black FKM element for a 3/4-inch ProPress CTS fitting under model 2986. That is the fitting size, rather than a measured loose-ring diameter. The model names the material family; the article number separates this size from the other rings in that family. [1] [3] [5]
The Amazon title names 17778 and a three-pack. Viega’s model 2986 article table lists a catalog quantity of five for that same part. Treat the maker’s table as the size and material reference, but do not assume the Amazon package contains five. Check the listing quantity and package label before planning how many replacements you need. [1] [4] [5] [9]
The FKM material range is 14 to 284°F. Its separate 356°F thermal-spike allowance lasts 24 hours or less. Neither figure overrides a lower limit in the application chart. For ProPress copper low-pressure steam, for example, FKM is specified at no more than 15 psig and 250°F, with adequate condensate drainage. [1] [2] [3]
Where it does well
- Maker maps part 17778 to 3/4-inch ProPress CTS fittings
- FKM option for documented nonpotable applications
- Published continuous and short-duration temperature limits
What to watch
- Not permitted for drinking water under the ProPress manual
- Amazon title says three-pack; maker catalog quantity is five
- Does not repair an already pressed joint
For a closed heating loop, document the fluid as well as its normal temperature. Viega recommends considering FKM when heating media run continuously at 200°F or above. That advice does not apply the same way to domestic hot-water recirculation: drinking water remains subject to the ProPress manual’s EPDM-only rule. [1] [2] [3]
Before pressing a 3/4-inch fitting, use the small-fitting replacement procedure. Viega calls for a suitable blunt object during removal and an undamaged replacement seated fully in the bead. Inspect the metal seat as well as the ring. A new sealing element cannot make a damaged fitting acceptable. [1] [4]
My call: choose 17778 when the specification calls for FKM in a 3/4-inch ProPress fitting. Resolve the three-versus-five quantity difference before relying on the package for several connections. If the service, size or fitting condition is unclear, have the plumber or Viega settle that question before assembly. [1] [3] [5] [9]
Viega 17823 FKM for 2-inch fittings
The 2-inch FKM element is part 17823 in Viega’s model 2986 catalog. The Amazon title identifies Viega ProPress, FKM, the 2-inch size and dull-black appearance, but omits the article number. Match the delivered package to the maker’s row before installation. The title alone does not provide every identifier. [1] [3] [5] [9]
Two inches is the upper end of the small-fitting procedure in Viega’s Changing Sealing Elements instructions. The 2-1/2 through 4-inch procedure is separate and involves separator and grip rings. A 2-inch 2986 element is therefore not an alternative to a 2-1/2-inch XL FKM element, even though both materials are FKM. [1] [3] [4] [5]
The material range remains 14 to 284°F at this size. A larger ring does not increase the application rating. On ProPress copper low-pressure steam, retain the 15-psig and 250°F limits and the condensate-drainage condition. Have a mechanical professional confirm steam isolation and safe depressurization before any installed piping is opened. [1] [2]
Where it does well
- Maker maps part 17823 to 2-inch ProPress CTS fittings
- Covered by the 1/2 through 2-inch replacement procedure
- Dull-black FKM identity documented in model 2986
What to watch
- Not permitted for drinking water under the ProPress manual
- Listing title omits the maker part number and pack quantity
- Not interchangeable with a 2-1/2-inch XL element
Compressed air needs an oil check before material selection. Viega’s chart distinguishes concentrations at or below 25 mg/m³ from those above that boundary. FKM appears in the higher-oil ProPress copper row, but the fluid identity and chart conditions still matter. An unknown compressor lubricant cannot be approved from the ring’s dull-black color. [1] [2] [3]
For an unpressed 2-inch fitting, remove the old element with a suitable blunt object and seat the correct undamaged replacement fully in the bead. Avoid metallic pointed or sharp objects. Inspect the fitting for damage or debris before the tube enters; a replacement ring is no cure for a scratched metal seat. [1]
My call: use the 2-inch choice only for a documented FKM application in that exact ProPress size. The listing does not state a pack count, so do not infer five from Viega’s catalog quantity or three from the smaller listing. Keep drinking-water and already-pressed repairs outside this replacement choice. [1] [3] [4] [9]
Compare the three seals
| Part and photo | Use | Key specs | Fit and limits | Buy |
|---|---|---|---|---|
Viega 2989 / 78242 | Drinking water or standard service before pressing | 1/2 inch; 0 to 250°F [1] | Only seal permitted for drinking water Title omits part number and pack count | Check it on Amazon |
Viega 2986 / 17778 | Approved FKM service before pressing | 3/4 inch; 14 to 284°F [1] [5] | Exact maker size mapping Three-pack title; catalog quantity five | Check it on Amazon |
Viega 2986 / 17823 | Approved FKM service before pressing | 2 inches; 14 to 284°F [1] [2] | Within small-fitting procedure Not for drinking water or XL fittings | Check it on Amazon |
EPDM is the factory-default ProPress seal and remains the only permitted material for drinking water in the manual. Its shiny-black appearance and 0 to 250°F material range are reference facts. FKM cannot replace that drinking-water approval. Sources: ProPress manual §§2.2.1 and 2.4.5; Seals and Gaskets TD-PP 0522. [1] [3]
Where the listing and maker details differ
| Part | Amazon listing | Viega catalog | What to check |
|---|---|---|---|
| 78242, 1/2-inch EPDM | Title states Viega model 2989, EPDM, shiny black and 1/2 inch; no part number or pack count [1] [9] | Model 2989; 1/2 inch; shiny black; part 78242 [1] [9] [10] | Confirm part 78242 and the pack count on the package. [10] |
| 17778, 3/4-inch FKM | Title states three-pack | Quantity column: five; 3/4 inch; dull black; part 17778 [1] [5] | Use the maker size/material mapping. Do not describe this Amazon offer as a five-pack. Confirm its three-pack quantity. |
| 17823, 2-inch FKM | Title states 2 inches and dull black; no part number or pack count [1] | Quantity column: five; 2 inches; dull black; part 17823 [1] [5] | Confirm package part 17823. Catalog quantity five does not establish this listing’s pack count. [5] |
Source: Viega U.S. catalog, “Viega ProPress sealing element – Model 2986,” Articles, parts 17778 and 17823, and model 2989, part 78242, accessed October 20, 2026. The catalog quantity and an individual seller’s package description can differ. [1] [5] [7] [9] [10]
What each press fitting seal is rated for
These ranges describe Viega’s U.S. sealing elements. EPDM, FKM and HNBR from another maker need that maker’s own data. A matching compound abbreviation does not establish an identical fitting approval.13
| Viega seal | Seal appearance | Material operating range | Additional boundary |
|---|---|---|---|
| EPDM | Shiny black | 0 to 250°F [1] | Only permitted material for the manual’s drinking-water installations |
| FKM | Dull black | 14 to 284°F [1] | Thermal spike to 356°F for 24 hours or less; application limits still govern [1] [2] |
| HNBR | Yellow | −40 to 180°F [1] | Model 0687 cannot provide LC-4 gas approval; not for drinking water [1] [6] |
The temperature number answers one question: whether the sealing material is within its stated temperature range. The application chart answers a different question: whether the named assembly is permitted for the fluid and operating conditions. Read both before you choose the ring.12
Use the more restrictive applicable boundary. For example, FKM’s 284°F material ceiling does not change the ProPress copper steam row’s 250°F ceiling. The same logic applies at the cold end: an EPDM material rating down to 0°F does not protect water-filled tubing from freezing. [1] [2] [3]
Use the system’s normal operating condition when you compare the application and seal limits. A sustained heating load is different from a brief temperature excursion.1
Have the designer or Viega check unlisted fluids or conditions outside the published chart. Do not commission a system on a material-temperature figure alone.1
Can this seal approve this job?
Start with the medium and named fitting system. Check its seal requirement and any condition that rules out the installation. The numbers apply only to the stated system and application.1
| Job | System | Seal | Service limits | Stop if | Source |
|---|---|---|---|---|---|
| Drinking water | U.S. ProPress copper | EPDM | Only EPDM permitted by the manual | FKM or HNBR substitution | Manual §2.2.1 [1] |
| Continuous hot hydronics | ProPress copper, approved heating medium | EPDM or FKM per specification | Consider FKM when media run continuously at 200°F or above [1] | Treating heating advice as potable-water permission | Application chart 0926, note 8 [1] [2] |
| Residential steam | ProPress copper | EPDM or FKM | 5 psig; maximum 227°F; adequate condensate drainage [1] [2] | Using the seal ceiling as the steam rating | Chart 0926, steam row and note 5 [1] [2] |
| Low-pressure steam | ProPress copper | FKM | 15 psig; maximum 250°F; adequate condensate drainage [1] [2] | EPDM substitution or inadequate drainage | Chart 0926, steam row and note 5 [1] [2] |
| Natural gas or propane conversion | ProPress with replacement model 0687 [6] | HNBR | Not permitted where ANSI/CSA LC-4 approval is required [1] | Installing a yellow replacement to claim gas approval | Model 0687 catalog note [6] |
| Natural gas or propane | MegaPressG | HNBR | 125 psig; −40 to 180°F in listed fuel rows [1] [2] | Transferring MegaPressG approval to copper ProPress | Chart 0926, fuel rows and note 10 [1] [2] |
| Oil-bearing compressed air | ProPress copper | Depends on oil concentration | Chart distinguishes ≤25 and >25 mg/m³; 200 psig; maximum 140°F [1] [2] | Unknown carryover oil or incompatible lubricant | Chart 0926, compressed-air rows [2] |
| Refrigerant or unlisted chemical | Exact purpose-approved system required | As specified for that system | A generic seal change provides no documented approval | Using FKM’s chemical resistance as refrigerant approval | Manual §2.3 and project-specific maker approval [1] |
Read the named-system column before the seal column. MegaPressG and copper ProPress are separate product systems. Seeing HNBR beside a fuel-gas rating for MegaPressG does not transfer that approval to a ProPress fitting that has been altered with a replacement ring.1234
For compressed air, the concentration of carried oil changes the ProPress copper seal choices in the chart. EPDM is checked in the lower-oil row, but not above 25 mg/m³. FKM and HNBR appear in the higher-oil row. Identify the compressor lubricant as well as its carryover concentration before specifying a seal. [1] [2] [3]
Application source: Viega Commonly Approved Applications, AP-PP-MP-PF 0926. Its footnotes are part of the rating. Systems outside the listed parameters require Viega Technical Services approval. [1] [2]
Ring color, fitting dots and package labels
A green dot on a Viega metal fitting and a black seal inside it can be correct at the same time. The dot is an external identifier; the ring is a separate component. Reading one color as if it described the other is an easy way to misidentify an unused fitting.17
Viega’s sealing-element explainer associates green dots with EPDM, white with FKM and yellow with HNBR on its metal fittings. The actual sealing elements are shiny black, dull black and yellow respectively. Confirm the product line and package rather than choosing a loose replacement by dot color.13479
| Where you look | Viega identifier | What to check next |
|---|---|---|
| Seal inside the bead | Shiny black EPDM; dull black FKM; yellow HNBR | Exact replacement model and fitting size |
| Dot on a metal fitting | Green EPDM; white FKM; yellow HNBR in Viega’s explainer | Named system and approved service |
| Bag or package | Part number and size; maker’s identification | Match the replacement to the fitting specification |
| A different maker’s ring | Color convention may differ | Use that maker’s document, not the Viega color key |
Eurotubi offers green FPM/FKM seals, and its source also lists red FPM/FKM for industrial applications. Viega identifies FKM with dull black seals. These colors belong to particular products and applications; they are not a universal code for every press fitting.138
A listing for a press ring may also describe a tool accessory rather than an elastomer seal. The steel rings used around large fittings during pressing are not replacement sealing elements. Search with the maker’s seal model, fitting size and material to avoid ordering a jaw or actuator accessory by mistake.149
Water and steam need separate checks
On a domestic hot-water recirculation line, the water remains potable. Apply the ProPress manual’s EPDM-only rule for drinking water. A closed heating loop has its own working fluid and specification. Do not let the shared phrase “hot water” merge those two applications.13
For hydronic and chilled-water applications, the chart gives a glycol concentration boundary of 50% or less for ethylene or propylene glycol. The actual mixture and additives still matter. If the system uses an unfamiliar inhibited fluid, have the designer obtain maker confirmation rather than approve it from the glycol percentage alone. [1]
| Condition to document | Water or hydronic example | Why it changes the decision |
|---|---|---|
| Fluid identity | Potable water versus closed-loop heating fluid | The drinking-water manual permits only EPDM |
| Mixture | Ethylene or propylene glycol at no more than 50% [1] | An unknown mixture cannot be matched to the chart row |
| Duty cycle | Heating media continuously at or above 200°F [1] | Viega recommends considering FKM for that heating condition |
| Steam pressure and temperature | 5 psig / 227°F versus 15 psig / 250°F [1] [2] | The higher steam row requires FKM for ProPress copper |
| Condensate handling | Adequate drainage on approved steam entries | A temperature-compatible seal does not solve poor drainage |
The ProPress copper water rows distinguish a 300-psig system operating rating from a 600-psi water test pressure. A test number is not a continuous service rating. It is also not an instruction to apply that pressure to an existing house system with other components attached. [1]
A mechanical professional should check every component before a steam conversion or repair. The residential and low-pressure steam entries have different limits, and both require condensate drainage. Keep steam isolation, cooldown and safe depressurization with that professional; a replacement-seal purchase is not a steam-work procedure.124
For an installed water or heating repair, have the plumber isolate the supply, let hot components cool and safely relieve trapped pressure before opening piping. Follow the connected equipment maker’s shutdown instructions. Do not open steam equipment or a hot pressurized fitting to inspect its ring.
Fuel gas, refrigerant and chemicals
For a gas project, give the qualified gas professional the actual fitting model and its listing requirements. A general elastomer description is insufficient. The ProPress replacement restriction remains relevant even if an online seller describes yellow HNBR as a material used in gas equipment.12349
An unlisted chemical mixture needs an application review. Viega’s chart says uses outside its listed applications or parameters must be approved by Technical Services. Supply the chemical name, concentration and operating conditions. A general FKM description cannot settle the compatibility of a particular process stream.123
If you smell fuel gas or suspect a gas leak, leave the area and contact the gas utility or emergency services from a safe location. Do not investigate it by loosening a fitting, operating a press tool or adding a different seal.12
Find the exact model and fitting size
These are maker catalog identifiers for Viega ProPress CTS sealing elements. A model names the family; the part number identifies its size. Catalog quantities are not a statement of what an Amazon package contains.19
| Material and family | Fitting size | Maker part number | Catalog reference |
|---|---|---|---|
| EPDM 2989 | 1/2 inch [1] | 78242 [10] | Shiny black; standard-size assembly |
| FKM 2986 | 1/2 inch [1] | 17768 [5] | Dull black; standard-size assembly |
| FKM 2986 | 3/4 inch [1] | 17778 [5] | Dull black; standard-size assembly |
| FKM 2986 | 1 inch [1] | 17788 [5] | Dull black; standard-size assembly |
| FKM 2986 | 2 inches [1] | 17823 [5] | Dull black; standard-size assembly |
| HNBR 0687 | 1/2 inch [1] | 21023 [6] | Yellow; LC-4 restriction applies [1] |
| EPDM 2989XL | 2-1/2 inches [1] | 78268 [11] | Shiny black; XL assembly |
Viega lists the 1/2-inch EPDM part under model 2989 and the 1/2-inch FKM part under model 2986. Those model numbers are not tubing sizes. The complete part number distinguishes a specific size from the broader material and model family. [1] [3] [5] [9] [10]
The larger 2-1/2 through 4-inch ProPress construction includes separator and grip rings. Its replacement procedure is separate from the 1/2 through 2-inch procedure. Do not stretch a smaller replacement or choose a generic ring because it appears close to the groove diameter. [1]
The model 0687 catalog’s LC-4 restriction concerns system approval, regardless of the seal’s yellow color. XL models belong to a different fitting assembly from the smaller 2989 and 2986 families. A shared material name does not establish interchangeability between those assemblies. [1] [5] [6] [9] [10]
When a sealing element can be changed
The installation manual says to replace damaged components and not repair them. A new ring cannot establish that a scratched or deformed metal seat is sound.
Treat the connection as a permanent press joint. Have a plumber diagnose the leak and plan the correct repair. Do not attempt to pull out and exchange the ring in place.
Viega calls the element a static seal: after pressing, it stays in a permanent connection. That distinction explains why a bag of replacement seals is useful during installation, but does not create a routine maintenance interval for completed joints. Do not apply a faucet’s serviceable O-ring procedure to a press fitting.147
The words “changing sealing elements” in the instruction title refer to assembling the correct fitting before pressing. They do not describe opening a completed joint like a union. If removal is needed, my press fitting removal guide covers the separate repair question.1
- Seat the undamaged replacement fully
Install the specified new sealing element into the bead. Check that the entire ring is in the bead before the tube enters the fitting.1
The small-fitting instruction is short because its ring can be placed directly in the bead. The XL procedure controls how the sealing element passes the separator and grip rings. These are different assemblies, so the shorter method should never be extended to a larger fitting merely because both use EPDM.134
Viega’s manual requires components to be free of debris and the sealing element to be intact and correctly located. Keep unused fittings clean and dry. If a replacement has been dropped into metal chips, do not insert it and hope the press cycle will compensate for contamination.14
Protect the seal when the tube goes in
| Check before pressing | Maker’s instruction | What to avoid |
|---|---|---|
| Tube end | Cut square without deforming the tube | Flame cutters or grease and oil during cutting |
| Inside and outside edges | Deburr both sides to the proper insertion depth | A sharp edge passing through the sealing element |
| Seal and bead | Correct element, undamaged, fully in the bead | A displaced ring or damaged fitting |
| Insertion mark | Measure and mark the required depth | Guessing that the tube reached the stop |
| Press tooling | Correct ProPress jaw or compatible ring and actuator | Assuming every tool that fits the diameter is approved |
Deburring protects the sealing element as the tube enters. Viega’s manual requires both inside and outside deburring. The manual also warns against pressing over grooves, stamped markings or engravings on the tube surface. A replacement ring cannot make a damaged sealing surface suitable.14
Mark the insertion depth for the exact fitting and size before pressing. My press fitting insertion-depth guide handles those measurements. Watch the mark during assembly so a correct seal is not paired with a tube that has slipped out before the press cycle.1
The seals technical sheet describes a factory-applied H-1 food-grade silicone oil lubricant. That statement does not approve an arbitrary jar of faucet grease, solvent or spray for field use. If lubrication is missing or contamination is suspected, have the installer obtain Viega’s direction for the exact component. [1] [3]
Keep hands and foreign objects clear of the press tool during its cycle, as the ProPress manual warns. Follow the tool maker’s safety and PPE instructions. Metallic piping also needs proper bonding; Viega assigns bonding testing and verification to a qualified electrician.1
What to confirm with the plumber
A useful seal specification identifies the job as well as the part. “Black ProPress O-ring” leaves both material and size unclear. Write down the fitting system and the intended medium before looking at a product photo. That keeps the appearance check from becoming the whole specification.1
| Record this | Example of a complete entry | Who resolves a missing answer |
|---|---|---|
| Fitting identity | Viega ProPress copper, unpressed, 1/2 inch [1] | Licensed plumber |
| Service | Potable water, rather than simply “hot water” | Plumber or system designer |
| Operating conditions | Documented normal and maximum temperature and pressure | Mechanical designer |
| Replacement | 2989 EPDM, part 78242, for the documented application [9] [10] | Installer with maker catalog |
| Restrictions | No gas conversion; no repair of a pressed joint | Licensed professional |
| Commissioning | Required inspections and pressure testing for the whole installation | Installer and local authority |
For an unfamiliar heating fluid, add its product name and concentration to that worksheet. For compressed air, add the lubricant identity and oil concentration. Those details let Viega compare the real installation to a chart row instead of offering an answer to a vague description such as “air line.”13
After assembly, Smart Connect helps identify unpressed connections during leak testing. Viega says that check does not replace testing required by local codes and standards. Have the installer carry out the applicable system test; do not use the absence of a visible drip as the only commissioning check.14
Questions about press fitting O-rings
What do the colors on press fittings mean?
In Viega’s metal-fitting explainer, green dots identify EPDM, white dots identify FKM and yellow dots identify HNBR. The actual seals are shiny black EPDM, dull black FKM and yellow HNBR. Read the package and exact fitting identity alongside the colors.1379
Other makers can use different colors. Eurotubi offers green FPM/FKM and also lists red FPM/FKM for industrial applications. The Viega color key cannot identify every loose press seal.138
How long do ProPress sealing elements last?
Viega describes its pressed sealing elements as permanent static seals, rather than routine replacement parts. The actual installation must stay within the approved application and operating conditions. A material-temperature rating does not establish a guaranteed service life for every building.147
If a joint leaks, have the plumber check the fitting and installation. Do not assign a replacement interval from a faucet O-ring or treat a service-life claim as proof that a particular damaged joint is sound.
Can I replace a seal before pressing a fitting?
Can I fix a leaking pressed fitting with a new O-ring?
Can I swap EPDM for HNBR to use ProPress for gas?
Viega’s model 0687 catalog explicitly prohibits installing its HNBR replacement elements in ProPress systems requiring ANSI/CSA LC-4 approval for natural gas or propane. Have a qualified gas professional select a fitting system with the required approval. Yellow material alone does not provide it. [1] [2] [3] [4] [6]
Can ProPress fittings be used on low-pressure steam?
The Viega application chart lists ProPress copper with FKM for low-pressure steam at 15 psig and a maximum 250°F. Its residential steam entry allows EPDM or FKM at 5 psig and a maximum 227°F. Adequate condensate drainage is required. [1] [2] [3]
Have a mechanical professional confirm the exact steam application and safe isolation. Do not substitute the seal material’s temperature ceiling for the lower service-row limit.12
Does an FKM seal approve a water fitting for refrigerant?
No approval follows from the seal change alone. The fitting system must be approved for the exact refrigerant and operating conditions. Have an HVAC professional confirm the manufacturer’s application documentation before choosing any refrigerant press connection.1
Can burrs or scratches damage the seal?
Is the substance around a fitting lubricant or a leak?
Can heat or oil damage a press fitting seal?
Conditions outside the approved temperature or fluid limits need maker review. Compressed-air seal selection changes with oil concentration, and Viega does not recommend HNBR for silicone-based oils. For work near heat, follow the manual’s joining precautions rather than rely on a material maximum.13
Is a generic O-ring with the same dimensions suitable?
Does a 600-psi water test figure mean 600-psi service?
Why I recommend these seals
I am a licensed journeyman plumber in Georgia. I have installed Viega ProPress, NIBCO Press and ApolloPress copper fittings on real jobs. If I could stock one copper press fitting brand, I would choose Viega ProPress. I match each replacement to the maker’s service restrictions and fitting size.14
How I chose
I read the ProPress manual, application chart, seals technical sheet and replacement instructions. I matched model 2989 part 78242 and model 2986 parts 17778 and 17823 to 1/2-inch, 3/4-inch and 2-inch fittings, then checked the Amazon offers on November 15, 2026. [1] [5] [7] [9] [10]
I give these seals no numerical score because approval is a fit requirement, not a contest. EPDM cannot earn permission for an FKM-only job, and FKM’s higher temperature ceiling cannot override the drinking-water rule.
Linked parts must be genuine Viega, new and in stock. My November 15 check found all three new and in stock: the EPDM ring from ZenSupplyInc, 17778 from KHC Shop and 17823 from Voomi Supply. The 17778 listing’s three-pack differs from the maker’s catalog quantity of five. [1] [5]
The seal limits here come from the named maker documents. My recommendations depend on fitting size and approved service. I checked the current CPSC recall results for Viega; the search returned no matching recalls.
| Selection check | Rule used |
|---|---|
| Application | Match the fluid and operating conditions to the named system |
| Part identity | Match maker model, part number and fitting size |
| Offer | Genuine Viega listing, new and in stock at my November 15, 2026 check [1] [7] |
| Image | Exact Amazon product photo for the listed seal |
| Safety | Retain service restrictions beside the recommendation |
| Scoring | None: fitting size and approved service are requirements, not points to average |
Sources
- Viega ProPress Systems Installation Manual, IM-PP 724607 1125: drinking-water restriction §2.2.1; seal descriptions §2.4.5; component inspection §4.1; deburring §4.7; pressing §4.8; testing §4.9. Read source
- Viega Commonly Approved Applications, AP-PP-MP-PF 0926: water, steam, fuel and compressed-air rows; notes 2 through 8 and 10. Read source
- Viega Seals and Gaskets Information, TD-PP 0522, pages 1–2: material ranges, appearance, FKM thermal-spike limit and factory lubricant. Read source
- Viega Changing Sealing Elements, PI-PP 530524 0120: separate procedures for 1/2 through 2-inch and 2-1/2 through 4-inch fittings; sharp grip-ring warning. Read source
- Viega U.S. catalog, Viega ProPress sealing element – Model 2986, Articles: 17778, 3/4-inch FKM, dull black, quantity five; 17823, 2-inch FKM, dull black, quantity five. Accessed October 20, 2026. Read source
- Viega U.S. catalog: sealing-element models 2989, 0687, 2989XL; article tables and model 0687 LC-4 restriction. Accessed October 20, 2026. Read source
- Viega Connecting the Dots on Sealing Elements, August 10, 2021: dot identifiers and permanent static-seal distinction. Read source
- Eurotubi, Update of VdS certification for the stainless steel line of pressfittings, June 2016: green and red FKM variants. Read source
- Amazon listing and availability checks, November 15, 2026: every product named on this page. All three new and in stock. Availability can change.
- Viega model 2989 catalog, part 78242, 1/2-inch shiny-black EPDM. Read catalog
- Viega model 2989XL catalog, part 78268, 2-1/2-inch shiny-black EPDM. Read catalog