Sewage ejector
Zoeller M267 sewage pump
at Amazon
Two pumps sit in basement floors and look broadly similar. They do completely different jobs, and putting the wrong one in is not a performance mistake. It’s a code violation and a health hazard.
As an Amazon Associate I earn from qualifying purchases. How this site earns

A sump pump moves groundwater out of a covered pit. A sewage ejector lifts toilet, shower and sink waste from a sealed, vented basin up to the sewer. They are not interchangeable, and one pit never does both jobs.
For a basement bathroom: Zoeller M267
at Amazon
For a wet basement: Zoeller M53
at Amazon
A sump pump moves groundwater. A sewage ejector pump moves sewage. Everything else follows from that. (Deciding between a sump pump and a yard drain instead? See sump pump vs French drain.)
A sump pump sits in a pit fed by drain tile around the foundation and pushes clean groundwater outside, away from the house. A sewage ejector sits in a sealed basin that receives waste from fixtures installed below the sewer line (a basement bathroom, a laundry, a wet bar) and lifts it up to the main drain. Neither one is the portable pump people mean by a utility pump: that has no pit and no float switch, and its job is clearing water that is already on the floor. See the best submersible utility pumps.
If that basement bathroom is the reason you are here, there is a third option this page does not cover: an upflush macerator, which avoids opening the slab entirely. See upflush toilet vs sewage ejector pump, and my upflush toilet picks.
| What | Sump pump | Sewage ejector |
|---|---|---|
| Handles | Clean groundwater | Sewage and solids |
| Solids capacity | Small solids only (1/2 in. on Zoeller’s M53 and M98) | Typically handles 2-inch solids |
| Basin | Covered, but not gastight | Sealed, gasketed, and vented |
| Discharges to | Outside / storm | The sanitary sewer or septic |
| Vent required | No | Yes |
A sump pump will not pass sewage solids and will jam or burn out on sewage. And the basin matters as much as the pump: an ejector basin must be sealed and vented, because sewer gas is both foul and hazardous. An open pit handling waste puts that gas straight into the room.
Going the other way is wasteful rather than dangerous: an ejector on groundwater works, it just costs far more than the job needs.
One sewage ejector and two sump pumps, all Zoeller, all cast iron, so you can see what each job takes side by side. All three were new and in stock on Amazon when I checked on Nov 11, 2026.

Sewage ejector
at Amazon

Sump pump, most basements
at Amazon

Sump pump, heavy inflow
at Amazon
Sewage ejector
The ejector for a basement bathroom basin
Zoeller’s sheet calls the M267 a sewage, effluent or dewatering pump for residential and light commercial sewage. It passes 2 in. spherical solids through a vortex impeller and moves up to 115 GPM at 5 ft, with a 20.5 ft shut-off head. Cast iron cap, motor housing, pump housing and base, a 1/2 HP oil-filled motor, and a 2 in. NPT discharge. The automatic version switches on at 12 in. and off at 4 in.
Best for: a toilet, shower or sink below the sewer line that drains into a sealed basin.
Skip it if: the pit only takes groundwater. A sump pump does that job for less.
From: Zoeller FM2789 Model 267 technical data sheet; Zoeller Model 267 product page (3 year limited warranty).
Sump pump, most basements
The everyday sump pump
A 3/10 HP oil-filled, cast iron sump pump with a 1-1/2 in. NPT discharge. Zoeller lists 1/2 in. spherical solids, a top flow of 43 GPM and a 19.25 ft shut-off head. The automatic version comes on at 7-1/4 in. and shuts off at 3 in. (The Amazon title says 1/3 HP; Zoeller’s sheet says 3/10 HP.)
Best for: a basement pit fed by drain tile with ordinary inflow.
Skip it if: a toilet drains into the pit. Zoeller says its dewatering and effluent sump pumps are not designed for pits handling raw sewage.
From: Zoeller FM2778 Mighty-Mate technical data sheet; Zoeller Model 53 product page (3 year limited warranty).
Sump pump, heavy inflow
More flow for a pit that fills fast
A 1/2 HP oil-filled sump pump with a cast iron motor housing and a 1-1/2 in. NPT discharge. Zoeller lists 1/2 in. spherical solids, up to 72 GPM and a 23 ft shut-off head, and it comes on at 9-1/2 in. and off at 3 in.
Best for: a pit that refills quickly or water with a long climb to get out.
Skip it if: the pit handles sewage, for the same reason as the M53.
From: Zoeller FM2779 Flow-Mate technical data sheet; Zoeller Model 98 product page (3 year limited warranty).
Every figure comes from Zoeller’s technical data sheets. The solids column is the whole story: 2 in. for the ejector, 1/2 in. for both sump pumps.
| Pump | Kind | Motor | Discharge | Solids it passes | Top flow | Shut-off head | Buy |
|---|---|---|---|---|---|---|---|
| Zoeller M267 | Sewage ejector | 1/2 HP | 2 in. NPT | 2 in. spherical | 115 GPM at 5 ft | 20.5 ft | Check it on Amazon |
| Zoeller M53 | Sump | 3/10 HP | 1-1/2 in. NPT | 1/2 in. spherical | 43 GPM | 19.25 ft | Check it on Amazon |
| Zoeller M98 | Sump | 1/2 HP | 1-1/2 in. NPT | 1/2 in. spherical | 72 GPM | 23 ft | Check it on Amazon |
Zoeller’s installation instructions cover its sump, effluent and sewage pumps in one document, so the differences are spelled out in one place.
Zoeller’s installation instructions say its dewatering and effluent sump pumps are not designed for pits handling raw sewage, and not to use a sump pump for pumping sewage.
On a sewage install, Zoeller’s sketch calls for gastight seals to contain gases and odors, and a vent pipe to the outside. It says the vent is not required for dewatering.
Zoeller says nothing but toilet paper goes into a non-grinder pump system: no wipes, paper towels, feminine hygiene items, dental floss or pads.
Zoeller says to install a check valve and a union in the discharge line, to drill a 3/16 in. vent hole in the pipe below the check valve, and that every installation needs a basin cover. It recommends a pit 18 in. or larger in diameter, and testing the system at least every three months.
Both share the same failure points, and both are worth getting right at install:
Symptoms overlap between the two: running but not emptying, short cycling, or silence. Start with sump pump not working. The diagnostic logic (power, float, check valve, blocked discharge) applies to both. A sensor on the floor beside either pit tells you it overflowed before the ceiling does: where to put water leak sensors.
No. A sump pump isn’t built to pass sewage solids and will jam or burn out, and a sewage application needs a sealed, vented basin that a sump pit doesn’t have. Sewer gas in the room is a real hazard, not a comfort issue.
If the fixtures sit below the main sewer line, yes. The waste has to be lifted. If it’s a sink or washer with no toilet, a smaller effluent pump is sometimes permitted; your local code decides, so ask the inspector first.
No. They must be separate, and routing groundwater into the sanitary sewer is illegal in most jurisdictions and can overwhelm the system.
It will move groundwater: Zoeller’s sheet lists the M267 for sewage, effluent or dewatering. It costs more than the job needs, and the ejector still needs its own sealed, vented basin if it ever handles sewage. Never let one pump serve both pits.
Yes, and nothing else. Zoeller says only toilet paper goes into a non-grinder pump system. Wipes, paper towels, feminine hygiene items, dental floss and pads put stress on the pump and can block the discharge pipe.
I’m Isaac Daniels, a licensed journeyman plumber in Georgia. In my 7 years of experience, these are the products I’d install. I’ve used all three pumps in this guide. Every pump figure here comes from Zoeller’s own technical data sheets, product pages and installation instructions, read on Nov 11, 2026, and each Amazon listing was matched to Zoeller’s model the same night.
Questions or corrections? Tell me here.
The pumps here follow the method in How I pick: maker documents, parts availability and fit, never commission rates.