Liberty P382LE51
Shown for comparison only.
Which one fits your basement, by the floor, the lift and the fixtures.
As an Amazon Associate I earn from qualifying purchases. How this site earns
Updated November 15, 2026

Pick a sewage ejector if you can cut the slab. Fixtures drain into a basin below the floor and a 2 in. pipe lifts it all; the linked ejector here is the Red Lion RL-WCS50TA kit, with the Liberty P382LE51 shown for comparison. If the slab has to stay whole, a Saniflo SaniPLUS upflush runs a full bath from on top of the floor.
Figures come from the makers’ own sheets, not the listings.
Shown for comparison only.

Shown for comparison only.
Shown for comparison only.
Shown for comparison only.
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product.
Red Lion RL-WCS50TA 14942749 sewage basin system, ½ hp cast-iron pump, 18 × 30 in. basin

Prices and availability are accurate as of the time shown and may change.
Your total lift is 15 ft or less, you want a narrow 18 in. hole in the slab, and you don’t mind assembling the kit.
Your lift is more than 15 ft, or you want a system that arrives assembled. Look at the Liberty P382LE51 below.
The RL-WCS50TA is Red Lion’s complete sewage basin kit, item 14942749. In the box you get an 18 by 30 in. polyethylene basin, a ½ hp sewage pump with a cast-iron base and impeller, a tethered piggyback float switch, the cover and its hardware, a 2 in. PVC discharge pipe that runs from the pump to the cover, and a 2 in. full-flow check valve.
Red Lion is a Franklin Electric brand.
Red Lion’s product table lists the pump at 9 A on 115 V with a 10 ft cord and a 2 in. FNPT discharge. It rates flow at 5,600 gallons per hour at 0 ft of lift, 4,920 at 5 ft, 3,720 at 10 ft, 1,680 at 15 ft and 480 at 20 ft, with shut-off at 22 ft.
Divided by 60, that’s about 28 gpm at 15 ft, above the 21 gpm the plumbing code asks of a pump on a 2 in. line, and about 8 gpm at 20 ft, well under it. Treat 15 ft of total dynamic head as the working limit.
The float turns the pump on at 17.5 in. and off at 7.5 in., per the same table. Red Lion’s manual sets the float 4 in. above the pump discharge on a 3.5 in. tether, clear of the pump, the pipe and the basin wall, and says to install the check valve level or at less than 45°.
The cover takes a 4 in. inlet, the 2 in. discharge and a vent through Adaptaflex flanges.
The score reflects that mix. It gets full marks for passing 2 in. solids and for a listing that matches the maker’s model, a 7 for kit completeness because the check valve is included but there’s no high-water alarm and you assemble it yourself.
Lift gets a 6 because the curve drops off past 15 ft. Warranty gets a 9 because the manual’s limited warranty runs 2 years from purchase. Add a float alarm, such as Liberty’s ALM-2 covered below, before you rely on it.
The biggest difference is where the work happens: on top of the slab, or down inside it.
An upflush unit sits on the floor behind or beside the toilet. Nothing goes into the slab. The catch is height: a shower or tub has to drain down into the pump’s side inlet, so its base sits 6 in. up for the SaniPLUS and 8 in. for the Sanibest Pro.
An ejector flips that. The basin goes into a hole in the slab, so every fixture sits at floor level and drains down into it by gravity, through pipe run under the slab.
The hole is real work. Liberty’s basin is 24 in. deep and about 24 in. across, and the Red Lion’s is 30 in. deep and 18 in. across. Liberty says to backfill with pea gravel or crushed stone and set the basin lip level with the finished floor.
Code sets the smallest pit at 18 in. across and 24 in. deep, with a gastight cover no more than 2 in. below the floor (IPC 712.3.2). Both basins here meet it.
Saniflo SaniPLUS 002 macerating pump with 087 elongated bowl and 005 tank
Shown for comparison only.
The SaniPLUS 002 is Saniflo’s ½ HP macerating pump for a full bathroom. This bundle pairs it with Saniflo’s 087 elongated bowl and 005 tank.
Saniflo rates it to lift 15 ft or push 150 ft sideways. Its sheet gives 17 gpm at 15 ft and 27 gpm at 3 ft, with a shut-off head of 30 ft. The pump runs about 10 to 12 seconds a cycle and holds 3 gal.
The toilet has to be Saniflo’s own 1.28 gpf rear-outlet model, which this bundle includes. The 087 bowl has a 16¾ in. seat height and is ADA compliant, per Saniflo. Two 2 in. side inlets with built-in check valves take a sink, a shower or tub, or a urinal.
Anything draining in must sit high enough to fall into those side inlets. The spec sheet says to raise a shower or tub base at least 6 in., and the 2010 install manual says 7 in. Build to 7 in. and both are met.
Waste leaves through ¾ or 1 in. rigid pipe. The manual says the pipe rises first, then falls ¼ in. per foot, and never climbs again once the horizontal run starts. It counts 3 ft of lift as 30 ft of run, and about 3 ft of lift lost per 90° turn.
It still needs a real vent. The 1½ in. port on the lid ties into an open vent, and Saniflo says air admittance valves and mechanical vents are not permitted. In many basements, that vent is the hardest pipe on the job, so find your route before you buy.
The limits are firm. The manual allows one toilet per unit and bars kitchen sinks, dishwashers and clothes washers. It also bars wipes, pads, tampons and swabs, and says not to use the system in a power cut. Saniflo lists noise at 53 dBA or less at 3 ft.
Saniflo Sanibest Pro grinder pump with elongated bowl and tank
Shown for comparison only.
The Sanibest Pro is Saniflo’s 1 HP grinder pump, part 013, for heavier work than the SaniPLUS. This bundle adds Saniflo’s elongated bowl and tank.
It lifts higher. Saniflo rates it for 25 ft up or 150 ft across, with 19 gpm at 25 ft and 38 gpm at 3 ft, and a shut-off head of 38 ft. That’s 10 ft more rated lift than the SaniPLUS, and 38 gpm against 27 at 3 ft.
The grinder is the big change. Saniflo’s sheet says it handles condoms, sanitary napkins, cotton swabs and dental floss, the items the SaniPLUS manual bars. It’s rated for homes and commercial use.
It also takes more fixtures. The sheet lists a sink, a shower or tub, a urinal and a washing machine, with the washer draining first into a laundry sink. The SaniPLUS manual bars washers outright.
The trade-offs are noise and height. Saniflo lists the Sanibest Pro at 63 dBA or less, against 53 for the SaniPLUS. A shower or tub base has to sit at least 8 in. off the floor, so plan a step up into the shower.
Discharge is the same ¾ or 1 in. rigid pipe, with the same rise-first rule. The vent is the same 1½ in. open vent, and Saniflo bars air admittance valves on it. A service panel on top lets you reach the inside without pulling the unit out.
It draws up to 9 A, weighs 28 lb and holds 3.2 gal. Saniflo’s warranty terms are the same as the SaniPLUS: 2 years from purchase, or up to 4 if you register online within the first year. Vitreous china parts carry 1 year.
One-piece macerating toilet, dual flush
Shown for comparison only.
The Sanicompact 023 is a one-piece toilet with the macerator built into its base. It’s for a half bath: a toilet and one sink.
Saniflo’s page calls it ventless, and its older sheet says it works as a forced main that doesn’t need a vent. That can save the hardest pipe on a basement job. Ask your inspector first: IPC 712.1 wants sumps vented, while 712.4.1 sends macerating toilets to the maker’s instructions.
Its lift is the lowest here, 9 ft. The run figure depends on the document: 120 ft in the headline, 150 ft in the spec table and 100 ft on an older sheet. Plan for 100 ft and every figure covers you. The older sheet gives 13 gpm at 9 ft.
The one inlet is 1¼ in., for a sink. No shower or tub can drain into it. The older sheet lists a dual flush of 1.28 or 1.0 gal from a push button on the bowl, with the motor running about 10 to 15 seconds.
It’s 18½ in. high, 14½ in. wide and 21½ in. deep, and weighs 64 lb. It discharges through 1 in. pipe. Saniflo lists 53 dBA, 7.2 A and 120 V, and the older sheet recommends a ground-fault (GFCI) outlet.
The documents disagree on the motor too: 0.5 hp on the current page and 0.3 HP on the older sheet. The figures that matter for the install, the 9 ft lift, the 1 in. pipe and the 1¼ in. sink inlet, match in both.
It’s certified to ASME A112.3.4 and CSA B45.9, the standard IPC 712.4.1 names for macerating toilets. Saniflo’s page lists a 4-year limited warranty, and its warranty terms say registering within the first year is what takes it past 2 years.
Sewage ejectors sit in a basin set into the slab. That’s a different kind of system from the upflush units above, so the two ejectors aren’t scored against them.
| P382LE51 | What the maker says |
|---|---|
| Specs | ½ HP, 12 A · 24 × 24.38 in. basin · 41 gal · 2 in. discharge · 4 in. inlet · 64 lb |
| Pick it if | You can cut the slab and want a full basement bathroom, maybe with a bar sink, with everything at floor level and lift to spare. |
| Skip it if | The slab can’t be cut. The SaniPLUS does a full bath from above the floor. |
| On Amazon | Reference (not linked) |
The P382LE51 is Liberty’s Pro380 simplex system: a ½ HP sewage pump already set in a basin, with floats, cover and discharge pipe. Liberty Pumps is a pump maker in Bergen, New York.
The basin is 24 in. tall and 24.38 in. across and holds 41 gal, per Liberty. That clears IPC 712.3.2, which asks for a pit at least 18 in. across and 24 in. deep. Liberty lists an optional 8 in. basin extension.
Fixtures drain in by gravity through a 4 in. no-hub inlet in the basin wall. Liberty’s drawing puts the inlet’s centre 14.75 in. up from the basin bottom. So the toilet, sink and shower all sit at floor level, with their drains run under the slab to the basin.
| Does well | Watch for |
|---|---|
| Ships assembled in a 24 in. basin | Slab cut and a 24 in. deep hole |
| About 90 gpm at 15 ft on Liberty’s curve | Needs a vent at least 2 in. |
| Floats lift out without pulling the pump | No wipes, pads, floss or swabs |
| Every fixture stays at floor level | No alarm with this model number |
| 3-year warranty | Draws 12 A |
Waste leaves through 2 in. Schedule 80 PVC, already fitted. Reading Liberty’s LE50 curve, I get about 90 gpm at 15 ft and 55 gpm at 20 ft, with flow stopping near 24 ft. IPC Table 712.4.2 asks 21 gpm of a pump on a 2 in. pipe.
Service is easy for a basin pump. Liberty’s QuickTree holder lets the floats lift out without pulling the pump, and a separate access cover gives a way in. The sales sheet says the system ships completely assembled, with an anti-flotation collar.
Liberty’s manual sets the rest of the pipe: a union just above the cover, then a check valve, then a gate or ball valve. The vent can’t be smaller than the discharge, so plan a 2 in. vent. Backfill with pea gravel or crushed stone, not sand or the dirt you dug out.
It draws 12 A at 115 V on a 10 ft cord. Liberty limits it to human waste and toilet paper: no wipes, pads, floss, swabs or grease. The warranty is 3 years, and the manual quotes the UPC rule that sewage systems need an audio and visual alarm.
| RL-WCS50TA | What the maker says |
|---|---|
| Specs | ½ hp, 9 A · 18 × 30 in. basin · 2 in. FNPT discharge · 4 in. inlet · 22 ft shut-off · On 17.5 in., off 7.5 in. |
| Pick it if | Your lift is 15 ft or less, you’d rather cut a narrow hole, and you don’t mind putting the kit together. |
| Skip it if | The lift is more than 15 ft, or you want it assembled. The Liberty P382LE51 has more head to spare. |
| On Amazon | Check it on Amazon |
The RL-WCS50TA is Red Lion’s sewage basin kit: an 18 by 30 in. basin, a ½ hp cast-iron pump, cover, discharge pipe and a 2 in. check valve. Red Lion is a Franklin Electric brand.
The basin is narrower and deeper than Liberty’s: 18 in. across and 30 in. deep. That’s exactly the IPC 712.3.2 minimum width, with 6 in. more depth than code asks. A narrower hole means less slab to cut, though you dig deeper.
Red Lion’s catalog gives flow in gallons per hour: 5,600 at 0 ft, 4,920 at 5, 3,720 at 10, 1,680 at 15 and 480 at 20, with shut-off at 22 ft. That’s about 28 gpm at 15 ft, above the 21 gpm code asks of a pump on a 2 in. pipe.
| Does well | Watch for |
|---|---|
| Basin, pump, cover and 2 in. check valve in one kit | You assemble it |
| About 28 gpm at 15 ft | About 8 gpm at 20 ft, under code’s 21 |
| Narrow 18 in. hole in the slab | 30 in. deep hole |
| Passes 2 in. semi-solids | 2-year warranty |
| No alarm in the kit |
At 20 ft it falls to about 8 gpm, well under that 21 gpm floor. So treat 15 ft of total dynamic head as the working limit for this kit. Total dynamic head is the vertical lift from the basin to the highest point of the discharge plus the friction loss in the pipe, valves and fittings, so a long or twisting run leaves less room for lift. Size the pump from the flow you need at your total head.
The pump passes 2 in. semi-solids, which lines up with the 2 in. solids IPC 712.4.2 asks of a pump that takes a toilet. Its piggyback float turns it on at 17.5 in. and off at 7.5 in., per the catalog. The base and impeller are cast iron.
It’s a kit, so you assemble it. The manual sets the float 4 in. above the pump discharge on a 3.5 in. tether, clear of the pump, pipe and basin wall. The check valve goes in level or tilted no more than 45°.
The cover takes a 4 in. inlet pipe, the 2 in. discharge and a vent through rubber Adaptaflex flanges. The pump draws 9 A at 115 V on a 10 ft cord. Red Lion’s manual gives a 2-year limited warranty from the date of purchase.
My call: it’s a good ejector for a basement bath with up to about 15 ft of total dynamic head, and the check valve is already in the box. Pick the Liberty for more lift, or if you’d rather not assemble anything.
Figures from the five picks’ maker sheets and the 2024 IPC. Scroll sideways on a phone.
| Check | Upflush (Saniflo) | Sewage ejector | Ahead |
|---|---|---|---|
| Slab work | None; sits on the floor | Cut and dig a pit 24 to 30 in. deep | Upflush |
| Shower or tub height | Base raised 6 to 8 in. | At floor level | Ejector |
| Toilet | Saniflo’s own rear-outlet bowl | A standard floor-outlet toilet | Ejector |
| Toilets per unit | One (SaniPLUS manual) | Set by pump and basin size | Ejector |
| Discharge pipe | ¾ or 1 in. rigid | 2 in. minimum (Liberty) | Upflush, smaller pipe to run |
| Flow at 15 ft | 17 gpm (SaniPLUS) | 28 gpm (Red Lion) to about 90 (Liberty) | Ejector |
| Highest lift | 9 to 25 ft rated | Flow stops at 22 to 24 ft | Close |
| Kitchen sink or washer | Not on the SaniPLUS | Not barred; Liberty bars grease | Ejector |
| Wipes and sanitary products | Sanibest Pro only | No (Liberty) | Sanibest Pro |
| Vent | 1½ in., no AAV; Sanicompact ventless | Not smaller than the discharge | Upflush |
| Published noise | 53 to 63 dBA | Not published | Can’t compare |
| In a power cut | Don’t use it | Drains into the basin until it fills | Ejector |
| Warranty | 2 years, up to 4 registered | Liberty 3 years, Red Lion 2 | Close |
Neither wins everywhere. The upflush wins on floor work and venting. The ejector wins on what it can take, how much it moves and how normal the bathroom looks once it’s done.
From each maker’s own sheet. Scroll sideways on a phone.
| Pick | Spec score | Type | Lift | Discharge | Vent | Shower or tub | Warranty | Buy |
|---|---|---|---|---|---|---|---|---|
| Liberty P382LE51 | None (ejector) | Ejector, 24 in. basin | Flow stops near 24 ft | 2 in. | 2 in. or more | At floor level | 3 years | Reference (not linked) |
| Red Lion RL-WCS50TA | 8.4 (ejector) | Ejector, 18 × 30 in. basin | Flow stops at 22 ft | 2 in. | Through the cover | At floor level | 2 years | Check it on Amazon |
| Saniflo SaniPLUS | , | Macerator, full bath | 15 ft rated | ¾ or 1 in. | 1½ in., no AAV | Base up 6 to 7 in. | 2 years, 4 registered | Reference (not linked) |
| Saniflo Sanibest Pro | , | Grinder, bath and laundry sink | 25 ft rated | ¾ or 1 in. | 1½ in., no AAV | Base up 8 in. | 2 years, 4 registered | Reference (not linked) |
| Saniflo Sanicompact | , | One-piece toilet, half bath | 9 ft rated | 1 in. | Ventless, per Saniflo | Not allowed | 2 years, 4 registered | Reference (not linked) |
Lift is the height from the pump to the highest point of the discharge pipe. More lift means less flow.
| Lift | SaniPLUS | Sanibest Pro | Sanicompact | Red Lion | Liberty (read from curve) |
|---|---|---|---|---|---|
| 3 ft | 27 gpm | 38 gpm | 16 gpm | Not listed | Not listed |
| 5 ft | Not listed | Not listed | Not listed | 82 gpm | About 140 gpm |
| 9 to 10 ft | Not listed | Not listed | 13 gpm at 9 ft | 62 gpm at 10 ft | About 120 gpm at 10 ft |
| 15 ft | 17 gpm | Not listed | Over its rating | 28 gpm | About 90 gpm |
| 20 ft | Over its rating | Not listed | Over its rating | 8 gpm | About 55 gpm |
| 25 ft | Over its rating | 19 gpm | Over its rating | Past shut-off | Past shut-off |
| Flow stops | 30 ft | 38 ft | Not listed | 22 ft | About 24 ft |
Red Lion’s figures are its gallons per hour divided by 60. Sanicompact flows are from Saniflo’s older sheet. Green: above the 21 gpm IPC Table 712.4.2 asks of a pump on a 2 in. pipe. Amber: below it.
The two sides are rated in different ways, so read the chart with care. Saniflo prints the highest lift it backs for each unit. Ejector makers print a curve, and the shut-off head is where the curve hits zero. You never want to run an ejector near that point.
Code gives the ejector side a floor. A pump on a 2 in. pipe has to move at least 21 gpm (IPC 712.4.2).
That floor is why I’d hold the Red Lion to about 15 ft of total dynamic head (lift plus pipe friction): it moves about 28 gpm there and only 8 at 20 ft. The Liberty still moves about 55 gpm at 20 ft on my reading of its curve.
Upflush units get their own rule. A macerating toilet serving one toilet can discharge through ¾ in. pipe (IPC 712.4.2, exception 2), and no gpm floor applies to that size.
Long runs cost lift. Saniflo’s SaniPLUS manual counts 3 ft of lift as 30 ft of horizontal run and takes about 3 ft off the rated lift for every 90° turn. Liberty says to keep the line short with few turns, and to go up a pipe size on long runs. Add your elbows before you settle on a model.
From the makers’ own lists. “Not listed” means the maker’s sheet doesn’t name it; ask the maker before you plan on it.
| Fixture or item | SaniPLUS | Sanibest Pro | Sanicompact | Liberty P382LE51 | Red Lion |
|---|---|---|---|---|---|
| Toilet | Saniflo rear-outlet, one per unit | Saniflo rear-outlet | Built in | Standard floor-outlet | Standard floor-outlet |
| Bathroom sink | Yes, 2 in. inlet | Yes | Yes, 1¼ in. inlet | Yes | Yes |
| Shower or tub | Yes, base up 6 to 7 in. | Yes, base up 8 in. | No | Yes, at floor level | Yes, at floor level |
| Urinal | Yes | Yes | Not listed | Not listed | Not listed |
| Washing machine | No | Yes, through a laundry sink | Not listed | Not listed | Not listed |
| Kitchen sink or dishwasher | No | Not listed | Not listed | Not listed; no grease | Not listed |
| Toilet paper | Yes | Yes | Yes | Yes | Yes |
| Wipes, pads, floss, swabs | No | Yes | Not listed | No | Not listed |
| Groundwater, or a drain that collects it | No, by code | No, by code | No, by code | No, by code | No, by code |
Sources: SaniPLUS install manual and spec sheet; Sanibest Pro and Sanicompact spec sheets; Liberty manual 7225000 (“human waste and toilet paper is permitted”; no grease); Red Lion catalog. Groundwater row: IPC 1101.3 and 1111.1.
The SaniPLUS list is the shortest, and it’s where most upflush complaints start. Wipes and pads jam a macerator, and the manual bars them by name. Keep them out of every system here. The Sanibest Pro’s grinder is built for heavier work, but that is not a reason to flush them.
Ejectors take more fixtures but are just as strict about wipes. Liberty bars feminine products, wipes, towels, floss and swabs in its non-grinder systems. For those, look at my sewage grinder pump guide.
Keep groundwater out of both. IPC 1101.3 bars storm water from a sewer meant only for sewage, and 1111.1 sends subsoil drains to their own sump. A perimeter drain, or a floor drain that collects groundwater or storm water, gets a sump pump, not the ejector. A sanitary floor drain is different: find out what the drain receives and ask your local code official where it may discharge. My sewage ejector vs sump pump guide covers the difference.
Both kinds push air out as they fill and pull air in as they empty, so both need a real vent.
| Pump flow (gpm) | 1½ in. vent | 2 in. vent | 3 in. vent | Which picks |
|---|---|---|---|---|
| Up to 40 | 160 ft | No limit | No limit | Saniflo units (38 gpm at most) |
| Up to 100 | 25 ft | 97 ft | No limit | Red Lion (about 93 gpm at 0 ft) |
| Up to 150 | Under 10 ft | 44 ft | 370 ft | Liberty (about 140 gpm at 5 ft) |
Longest vent run allowed by pump flow, excerpted from IPC 2024 Table 906.5.1. The length includes an allowance for fittings; code assumes 50% of the pipe length if you have no better figure. Check the full table for your exact flow.
Saniflo is clear about its units: a 1½ in. vent from the lid to an open vent, and no air admittance valves or mechanical vents. The SaniPLUS sheet calls for a two-way vent, because air has to move both ways. The Sanicompact is the exception; Saniflo sells it as ventless.
Ejectors follow the same thinking. Liberty’s manual says the vent can’t be smaller than the discharge, so its 2 in. pipe needs at least a 2 in. vent. IPC 918.8 bars air admittance valves on sumps unless an engineer designed the vent. My AAV vs vent guide explains why a sealed pit needs a vent that lets pressure out.
The vent can join the building’s vent system or run on its own to the outdoors, per Liberty. Plan that route first. In a finished basement, it’s often the hardest pipe to fit.
From IPC 2024 section 712 and the makers’ manuals.
| Rule | Upflush (Saniflo) | Ejector | Source |
|---|---|---|---|
| Pipe size | ¾ or 1 in. rigid | 2 in. minimum for a non-grinder | Saniflo sheets; Liberty manual; IPC 712.4.2 |
| Pipe material | Rigid, not flexible | Copper, CPVC, ductile iron, PE or PVC | SaniPLUS manual; IPC 712.3.3.1 |
| Valves | Non-return valve in the elbow, plus a full-port valve and a union | Union, then a check valve, then a full-open valve, above the cover | SaniPLUS manual; Liberty manual; IPC 712.2 |
| Route | Straight up first, then ¼ in. per foot of fall | As short as possible, with few turns | SaniPLUS manual; Liberty manual |
| Tie-in | An approved wye | A wye into the top of the pipe, 10 pipe diameters from a stack base | SaniPLUS manual; IPC 712.3.5 |
The check valve is what stops the pipe draining back after each cycle. Saniflo builds a non-return valve into the SaniPLUS discharge elbow. On an ejector, IPC 712.2 wants a check valve and a full-open valve, reachable, above the cover. The Red Lion kit includes its 2 in. check valve. My check valve guide covers how they’re fitted.
The full-open valve after the check valve lets you shut the line to clean the check valve or pull the pump, as Liberty’s manual puts it. A union just above the cover lets the pump come out without cutting pipe.
The tie-in rule matters on both sides. Ten pipe diameters from a stack base is 30 in. on a 3 in. drain. Keep the wye on top of the pipe, never the side.
| Item | Liberty P382LE51 | Red Lion | SaniPLUS | Sanibest Pro | Sanicompact |
|---|---|---|---|---|---|
| Hole in the slab | About 24 in. across, 24 in. deep | About 18 in. across, 30 in. deep | None | None | None |
| Shower or tub base | Floor level | Floor level | 6 in. (sheet), 7 in. (manual) | 8 in. | No shower |
| Weight | 64 lb | Not listed | 18 lb pump | 28 lb pump | 64 lb |
| Current | 12 A, 115 V | 9 A, 115 V | 4.5 A, 120 V | 9 A | 7.2 A, 120 V |
| Cord | 10 ft | 10 ft | 47½ in. | Not listed | Not listed |
| Outlet | Not stated | Not stated | 15 A GFCI, 40 in. from a tub or shower | Not stated | GFCI recommended |
Basement fixtures that can drain to the sewer by gravity shouldn’t go to the pump. IPC 712.1 says that in new work, a sump can’t take drainage from piping that could flow to the sewer on its own. So upstairs fixtures stay on the gravity drain, and only the basement fixtures go into the basin or the macerator.
The SaniPLUS cord is under 4 ft, so the outlet has to sit close behind the toilet. Saniflo wants it on a 15 A GFCI circuit at least 40 in. from a tub or shower. The ejectors carry 10 ft cords, so the outlet can sit on a nearby wall above the slab.
Check your local electrical code for the outlet; the makers’ figures here are the minimum.
Neither kind pumps without power. What happens next is different.
Saniflo’s SaniPLUS manual says not to use the system during a power loss. With no power, the pump can’t empty its tank.
Fixtures still drain into the basin until it fills. Liberty’s holds 41 gal in total.
The SaniPLUS manual says a constant drip can trip the motor’s thermal overload, and the unit can flood.
A high-water alarm sounds before the tank or basin overflows. Liberty’s manual quotes the UPC rule that sewage systems need one.
For a Saniflo unit, Saniflo’s Sanialarm is the high-water alarm the SaniPLUS sheet recommends.
For an ejector, Liberty’s ALM-2 is a float alarm on a 20 ft cord, the alarm Liberty’s /A2 models ship with. Check it on Amazon.
The P382LE51 and the Red Lion kit come without an alarm, so add one. A full basin backs up through the lowest drain in the basement. My sump pump alarm guide covers more alarm types.
| Task | Upflush (Saniflo) | Ejector | Source |
|---|---|---|---|
| Routine cleaning | Clean once a year, no bleach; Saniflo recommends its descaler | Keep grease, wipes and sand out | SaniPLUS manual; Liberty manual |
| Toilet tank | No bleach blocks in the tank | Not stated | SaniPLUS manual |
| Floats or switch | Membrane switch inside the unit | Liberty floats lift out on the QuickTree; Red Lion float on a 3.5 in. tether | Liberty; Red Lion manuals |
| Check valve | Built into the discharge elbow | Shut the full-open valve and clean it | Liberty manual |
| Cold rooms | Winterize with plumber’s antifreeze | Not stated by either maker | SaniPLUS manual |
| Leaks at fixtures | Fix drips; they can trip the overload | Not stated | SaniPLUS manual |
Neither maker publishes a lifespan in the sheets I read. What they do publish is the warranty: 2 years for Saniflo, up to 4 if registered in the first year, 3 years for Liberty and 2 for Red Lion. Treat any lifespan figure without a source as a guess.
Ejector. The Liberty P382LE51 for the most lift, or the Red Lion up to about 15 ft.
Upflush. The SaniPLUS, with a shower base raised 7 in.
The Sanibest Pro, or an ejector if the slab can be cut.
The Sanibest Pro (25 ft rated) or the Liberty (about 55 gpm at 20 ft).
The Sanicompact: toilet and sink, 9 ft of lift, ventless per Saniflo.
Not the SaniPLUS or Sanicompact. An ejector, kept free of grease.
Five places the makers’ own papers, or the web, don’t match, and which figure to plan on.
| Topic | One source says | The other says | Plan on |
|---|---|---|---|
| SaniPLUS shower base | Spec sheet: 6 in. minimum | 2010 install manual: 7 in. | 7 in. |
| Sanicompact horizontal run | Headline 120 ft; spec table 150 ft | Older sheet: 100 ft | 100 ft |
| Saniflo warranty | Product pages: 4 years | Warranty terms: 2 years, up to 4 if registered in year 1 | Register it |
| Sanicompact vent | Saniflo: ventless | IPC 712.1: sumps are vented; 712.4.1 defers to the maker | Your inspector’s call |
| How long they last | Pump-maker blog: upflush 10 to 15+ years, no source | Saniflo, Liberty and Red Lion sheets: no years figure | The warranty |
The shower-base gap is the one that costs a rebuild. An inch short and the shower drains slowly or backs up into the pan. Framing to 7 in. meets both Saniflo documents.
On the vent, the inspector decides. Some will pass a ventless Sanicompact under 712.4.1 and its listing; others will want a vent. Ask before the walls close.
| Question | If yes | If no |
|---|---|---|
| Can the slab be cut and dug 24 to 30 in.? | Ejector is on the table; keep going | Upflush |
| Will a kitchen sink, dishwasher or washer drain in? | Ejector, or the Sanibest Pro for a washer via a laundry sink | Keep going |
| Is the lift over 15 ft? | Liberty or Sanibest Pro | Any pick fits |
| Is there a shower or tub? | Ejector, SaniPLUS or Sanibest Pro | Sanicompact is enough |
| Can you run a vent to the outdoors or the building vent? | Any option, if its lift rating covers your run | Sanicompact, if your inspector accepts ventless |
| Will wipes or sanitary products get flushed? | Stop that first; no system here is meant for them | Any option, if its lift rating covers your run |
If you can cut the slab, I’d go ejector for a full bath. It takes a standard toilet, the shower sits at floor level, and nothing in the bathroom looks unusual.
If the slab can’t be cut, the SaniPLUS is the full-bath pick, and my best upflush toilet guide compares more macerating units. For more ejector pumps on their own, see my sewage ejector pump guide.
An ejector, if you can cut the slab: a standard toilet, a shower at floor level and a 2 in. pipe. An upflush, if you can’t: it sits on the floor, but showers need a raised base and the SaniPLUS bars kitchen sinks and washers.
Yes. Liberty’s manual says human waste and toilet paper are permitted. It bars wipes, feminine products, towels, floss and swabs in its non-grinder systems. A grinder pump, like the Sanibest Pro on the upflush side, is built for those.
The SaniPLUS manual names the big ones: wipes and sanitary products jamming the macerator, a dripping faucet tripping the thermal overload and flooding, and no use during a power cut. Saniflo also says to clean it once a year, without bleach.
No. IPC 1101.3 bars storm water from a sewer meant only for sewage, and 1111.1 sends subsoil drains to their own sump. Groundwater, and floor drains that collect it, get a separate sump pump. A sanitary floor drain is different; ask your local code official where yours may discharge.
Liberty, Red Lion and Saniflo don’t publish a lifespan in the sheets I read. Their warranties are the figures they stand behind: Liberty 3 years, Red Lion 2, Saniflo 2, or up to 4 if registered in the first year.
The SaniPLUS and Sanibest Pro do: a 1½ in. open vent from the lid, and Saniflo bars air admittance valves. Saniflo sells the Sanicompact as ventless. Ask your inspector, since IPC 712.1 calls for sumps to be vented.
Yes. IPC 712.1 calls for a tightly covered, vented sump, and Liberty says the vent can’t be smaller than the discharge. IPC 918.8 bars an air admittance valve on a sump unless an engineer designed the vent.
Saniflo rates the Sanicompact at 9 ft, the SaniPLUS at 15 ft and the Sanibest Pro at 25 ft of lift. Each 90° turn takes about 3 ft off, per the SaniPLUS manual.
Yes, on the SaniPLUS or Sanibest Pro. The shower or tub has to drain down into the side inlet, so its base sits at least 6 in. up for the SaniPLUS (7 in. per its manual) and 8 in. for the Sanibest Pro.
Saniflo units use ¾ or 1 in. rigid pipe, which IPC 712.4.2 allows for a macerating toilet serving one toilet. Ejectors that take a toilet use 2 in. pipe, and Liberty sets 2 in. as the minimum for a non-grinder.
Yes. IPC 712.2 calls for a check valve and a full-open valve after it, above the cover and reachable. Liberty adds a union just above the cover. The Red Lion kit includes a 2 in. check valve.
Not into the SaniPLUS; its manual bars washers. The Sanibest Pro takes a washer that drains first into a laundry sink. An ejector basin isn’t limited by either ejector maker’s sheet.
I compare the system requirements with the installation you have planned. Code text comes from the 2024 IPC; figures from Saniflo’s, Liberty’s and Red Lion’s own sheets and manuals.